Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Welding for repair f fire escapes bfd paid detail required ![]() Permit status: Na | Permit id: Cbw220135 | Parcel: 0503727000 | |||||
SCORE 89 Kitchen bedrooms and bath remodel Client: Jocote Llc | Permit type: Electrical | Permit status: Open | Current use: 1-2fam | Permit id: E639068 | Parcel: 0503727000 | |||||
SCORE 100 Install a 8 amp meter band 13 space with public bypass meter. Mount the meter band on the wall of the boiler room. Run two 3" emt conduits from the main electrical room. Run a total of 12 conductors 250kcm al 6 conductors in each conduit and two conductors sized for the service ground. Tie in the feed into a splice can in the electrical room and land the wires on the buss of the meter bank. Run new sub feeders from the meter bank to the electrical panels in each unit. Disconnect the existing sub feeder that connected each panel. Client: Jocote Llc | Permit type: Electrical | Permit status: Open | Current use: Multi | Permit id: E646936 | Parcel: 0503727000 | |||||
SCORE 93 Complete renovation unit # 5 add a bathroom. Client: Jocote Llc | Permit type: Renovations -interior nsc | Permit status: Open | Current use: Multi | Permit id: Sf629915 | Parcel: 0503727000 | |||||
SCORE 100 Replace entry door. See administrative approval #14. 1093 Client: Tosi Carlos | Permit type: Interior/exterior work | Current use: 1-2fam | Permit id: Sf404886 | Parcel: 503727000 | |||||
SCORE 100 Replace entry door. See administrative approval #14. 1093 Client: Tosi Carlos | Permit type: Short form bldg permit | Expiration date: March 5, 2015 | Current use: 1-2fam | Permit id: Sf404886 | Parcel: 0503727000 | |||||
Welding for repair f fire escapes bfd paid detail required ![]() Client: Tosi Carlos | Permit type: Bfd cutting-burning-welding | Permit id: Cbw220135 | Parcel: 0503727000 | |||||
SCORE 89 Kitchen bedrooms and bath remodel Client: Jocote Llc | Permit type: Electrical permit | Expiration date: March 21, 2017 | Current use: 1-2fam | Permit id: E639068 | Parcel: 0503727000 | |||||
SCORE 100 Install a 8 amp meter band 13 space with public bypass meter. Mount the meter band on the wall of the boiler room. Run two 3" emt conduits from the main electrical room. Run a total of 12 conductors 250kcm al 6 conductors in each conduit and two conductors sized for the service ground. Tie in the feed into a splice can in the electrical room and land the wires on the buss of the meter bank. Run new sub feeders from the meter bank to the electrical panels in each unit. Disconnect the existing sub feeder that connected each panel. Client: Jocote Llc | Permit type: Electrical permit | Expiration date: May 8, 2017 | Current use: Multi | Permit id: E646936 | Parcel: 0503727000 | |||||
SCORE 93 Complete renovation unit # 5 add a bathroom. Client: Jocote Llc | Permit type: Short form bldg permit | Expiration date: February 24, 2017 | Current use: Multi | Permit id: Sf629915 | Parcel: 0503727000 |