Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 76 Low voltage single celluar repair system. Only..... Date: April 10, 2006 Contractor: Communication Builders Inc Permit type: Permit - electric wi | Permit id: 100047654 | |||||
SCORE 61 One story slab on grade emergency room department addition to hospital with steel frame structure and non-load bearing masonry exterior walls as per plans Permit type: Permit - new constru | Permit id: 100202369 | |||||
SCORE 100 Installation of (1) 30 amp dual pole breaker and circuits in existing 200 amp service panel Permit type: Permit - electric wi | Permit id: 100206501 | |||||
SCORE 95 Replace existing temporary emergency generator with new 300 kw diesel engine generator for standby emergency power to two (2) existing fire pumps (1-60 hp; 1-40 hp). Dbec c-7455. Replace two (2) existing automatic transfer switches. Permit type: Permit - electric wi | Permit id: 100212957 | |||||
SCORE 100 Grind and tuck-pointing masonry repairs to south facade of an existing four story hospital. Subject to field inspection Permit type: Permit - easy permit | Permit id: 100315384 | |||||
SCORE 100 Install 24 square foot led illuminated channel letters to the north elevation of the building, to read ""main entrance."" Permit type: Permit - signs | Permit id: 100316870 | |||||
SCORE 95 Elevator cab interior modernization on north and south elevators. Pursuant to scope of work submitted. Permit type: Permit - elevator eq | Permit id: 100342264 | |||||
SCORE 92 Install 5 new antennas and 1 electrical cabinet to an existing wireless communications facility as per plans. Permit type: Permit - renovation/ | Permit id: 100359435 | |||||
SCORE 64 Roseland community hospital 45 west 111th street-proposed adolescent behavioral health center renovation-reconfiguring and renovating the existing med-surg unit to accomodate psychiatric patients 10,255 s. F. Permit type: Permit - renovation/ | Permit id: 100381853 | |||||
SCORE 95 East passenger 5-stop; cab panels replacement & fixture replacement. North & south passenger 6-stop; fixture replacement. Kitchen passenger 5-stop; fixture replacement. Ambulatory 5-stop; door operator replacement. All traction elevators. Pursuant to scope of work submitted and city of chicago department of buildings elevator bureau inspection. Permit type: Permit - elevator eq | Permit id: 100383452 | |||||
SCORE 95 Modernize one (1) 5-stop traction passenger elevator. Upgrade new controls, motor, fixtures, etc... Pursuant to scope of work submitted. Permit type: Permit - elevator eq | Permit id: 100387003 | |||||
SCORE 95 3 antenna change out on existing cell site Permit type: Permit - electric wi | Permit id: 100401450 | |||||
SCORE 64 Replace two walk in coolers and evaporators on the first floor, reuse the condensers. Replace one walk in cooler in the basement with a russell 1 1 4 hp condenser, and one walk in freezer in the basement with a russell 3 hp condenser, remote air cooled r404a, located on top of the boxes. Date: October 14, 2011 Contractor: Roseland Community Hospital Permit type: Permit - easy permit | Permit id: 100414825 | |||||
SCORE 100 Dc connection to new upgrade system module ch42677c Permit type: Permit - electric wi | Permit id: 100447136 | |||||
SCORE 100 One outlet Permit type: Permit - electric wi | Permit id: 100538677 | |||||
SCORE 100 Replacing an existing class-ii f. A. System in a hospital. B,1-5 ph fls. Ck#2479319;500. 00. Date: May 29, 2014 Contractor: Linear Electrical Inc Permit type: Permit - electric wi | Permit id: 100394413 | |||||
SCORE 95 Elevator cab interior modernization on north and south elevators. Pursuant to scope of work submitted. Permit type: Permit - elevator equipment | Permit id: 100342264 | |||||
SCORE 100 Dc connection to new upgrade system module ch42677c Permit type: Permit - electric wiring | Permit id: 100447136 | |||||
SCORE 95 3 antenna change out on existing cell site Permit type: Permit - electric wiring | Permit id: 100401450 | |||||
SCORE 100 Install 24 square foot led illuminated channel letters to the north elevation of the building, to read "main entrance." Permit type: Permit - signs | Permit id: 100316870 | |||||
SCORE 64 Replace two walk in coolers and evaporators on the first floor, reuse the condensers. Replace one walk in cooler in the basement with a russell 1 1 4 hp condenser, and one walk in freezer in the basement with a russell 3 hp condenser, remote air cooled r404a, located on top of the boxes. Date: October 14, 2011 Contractor: Roseland Community Hospital Permit type: Permit - easy permit process | Permit id: 100414825 | |||||
SCORE 95 Modernize one (1) 5-stop traction passenger elevator. Upgrade new controls, motor, fixtures, etc... Pursuant to scope of work submitted. Permit type: Permit - elevator equipment | Permit id: 100387003 | |||||
SCORE 95 East passenger 5-stop; cab panels replacement & fixture replacement. North & south passenger 6-stop; fixture replacement. Kitchen passenger 5-stop; fixture replacement. Ambulatory 5-stop; door operator replacement. All traction elevators. Pursuant to scope of work submitted and city of chicago department of buildings elevator bureau inspection. Permit type: Permit - elevator equipment | Permit id: 100383452 | |||||
SCORE 95 Installation of (1) amp dual pole breaker and circuits in existing 2 amp service panel Permit type: Permit - electric wiring | Permit id: 100206501 | |||||
SCORE 61 One story slab on grade emergency room department addition to hospital with steel frame structure and non-load bearing masonry exterior walls as per plans Permit type: Permit - new construction | Permit id: 100202369 | |||||
SCORE 95 Grind and tuck-pointing masonry repairs to south facade of an existing four story hospital. Subject to field inspection Permit type: Permit - easy permit process | Permit id: 100315384 | |||||
SCORE 64 Roseland community hospital 45 west 111th street-proposed adolescent behavioral health center renovation-reconfiguring and renovating the existing med-surg unit to accomodate psychiatric patients 10,255 s. F. Permit type: Permit - renovation/alteration | Permit id: 100381853 | |||||
SCORE 100 Replacing an existing class-ii f. A. System in a hospital. B,1-5+ph fls. Ck#2479319;500. 00. Date: May 29, 2014 Contractor: Linear Electrical, Inc Permit type: Permit - electric wiring | Permit id: 100394413 | |||||
SCORE 85 Low voltage single celluar repair system. Only..... Date: April 10, 2006 Contractor: Communication Builders, Inc Permit type: Permit - electric wiring | Permit id: 100047654 | |||||
SCORE 100 One outlet Permit type: Permit - electric wiring | Permit id: 100538677 | |||||
SCORE 95 Replace existing temporary emergency generator with new 3 kw diesel engine generator for standby emergency power to two (2) existing fire pumps (1- hp; 1- hp). Dbec c-7455. Replace two (2) existing automatic transfer switches. Permit type: Permit - electric wiring | Permit id: 100212957 | |||||
SCORE 91 Remove and replace 3 panel style antennas and 3 radio units mounted to existing cell tower, utilizinf existing mounts, dc cables and fiber trunks for tmobile site #ch42677c Permit type: Permit - electric wiring | Permit id: 100695832 | |||||
SCORE 83 1. New 480-volt, 150-amp power to mri trailer2. Change power feed to ct scanner from 208-volt, 125-amp to 480-volt, 125-amp3. Change power feed to rtu of ct scanner room from 480-volt, 20-amp to 480-volt, 25-amp Permit type: Permit - electric wiring | Permit id: 100701348 | |||||
SCORE 81 Replace (3) existing antennas with (3) new antennas, and add ancillary equipment. No changes to ground equipment, existing use or structure height. Previous permit number #100055483. T-mobile site #ch42677c. Permit type: Permit - renovation/alteration | Permit id: 100697642 | |||||
SCORE 61 Change electrical service for existing fire pump and provide emergency power to fire pumps.(no architectural work.) Permit type: Permit - renovation/alteration | Permit id: 100172990 |