Zoning use permit Date: January 4, 2017 Permit status: Completed | Permit id: 746427 | |||||
SCORE 97 For the erection of an attached structure with a walk out roof deck at the fourth floor level. Size and location as shown in application. For use as single family household living with two (2) accessory, off-street, enclosed parking spaces. See a p 746422 for plans Date: January 4, 2017 Contractor: Rock Construction Permit type: Zoning/use permit | Permit status: Completed | Completion date: January 4, 2017 | Permit id: 746427 | |||||
SCORE 96 Install new 200amp service complete with panel, meter and grounding recessed llights, recepts, 55 switches, smokes co detectors, exterior lights and tv lines as per 2008 nec (north district) Date: December 1, 2017 Contractor: Allwire Electric Llc Permit type: Electrical permit | Permit status: Active | Completion date: December 1, 2017 | Permit id: 836055 | |||||
SCORE 97 Construction of four story attached structure with interior garage, cellar, and roof deck. Use as single family household living. Plans approvde under permit ap# 748324. Date: May 1, 2017 Contractor: Rock Construction Permit type: New construction permit | Permit status: Active | Completion date: August 3, 2017 | Permit id: 778607 | |||||
SCORE 100 Install 40,0 btu 95% gas furnace in basement,install 80,0 btu 95% gas furnace on 3rd fl with air and related duct work Date: October 26, 2017 Contractor: Anthony Casile Permit type: Mechanical permit | Permit status: Active | Completion date: November 16, 2017 | Permit id: 827121 | |||||
SCORE 89 For the installation of a two (2) inch fire service line with backflow preventer and automatic fire suppression system as per nfpa 13r. All work shall be done in accordance with approved plans. See ap#783565 for plans and documents. Date: June 15, 2017 Contractor: Aqueduct Fire Protection Permit type: Suppression permit | Permit status: Active | Completion date: July 7, 2017 | Permit id: 791506 | |||||
SCORE 82 Install 4 water closets,6 lavs,3 showers,1 kitchen sink,1 washer box,pex and cast iron,5"lateral,1"domestic water service,curb trap,fai and 4" main drain-pa1#20171914267-"self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection"the installation will comply with the philadephia plubming code 2004 Date: July 20, 2017 Contractor: Frankie D Plumbing And Heating Permit type: Plumbing permit | Permit status: Active | Completion date: August 16, 2017 | Permit id: 801565 |