Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Plumbing permit ![]() Client: Yuval Llc | Permit status: Completed | Permit id: 678796 | |||||
Zoning/use permit ![]() Client: Yuval Llc | Permit status: Completed | Permit id: 680407 | |||||
New construction permit ![]() Client: Yuval Llc | Permit status: Active | Permit id: 697604 | |||||
Demolition permit ![]() Client: Yuval Llc | Permit status: Completed | Permit id: 723226 | |||||
Zoning use permit ![]() Client: Yuval Llc | Permit status: Completed | Permit id: 680407 | |||||
Plumbing permit ![]() Client: Yuval Llc | Permit status: Completed | Permit id: 678796 | |||||
SCORE 79 Install (4) hvac systems with ductwork. (multi-family) ![]() ![]() Client: Yuval Llc | Permit type: Mechanical permit | Permit status: Active | Completion date: November 24, 2017 | Permit id: 834518 | |||||
SCORE 100 Supply and install new 1" domestic,curb trap and fai pa20173251513(multi family) "self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" ![]() ![]() Client: Yuval Llc | Permit type: Plumbing permit | Permit status: Active | Completion date: November 22, 2017 | Permit id: 834323 | |||||
SCORE 56 For the placement of underpinning in the basement of a multi-family dwelling as per engineers plan, underpinning only - additional permits are required for all other work ![]() ![]() Client: Yuval Llc | Permit type: Alteration permit | Permit status: Active | Completion date: November 16, 2017 | Permit id: 823997 | |||||
SCORE 100 Installation of 400a service and wire throughout for outlet, switches, lights, smokes according to nec code 2008 west district & install fire alarm system throughout according nfpa 72. ![]() ![]() Client: Yuval Llc | Permit type: Electrical permit | Permit status: Active | Completion date: October 17, 2017 | Permit id: 816198 | |||||
SCORE 89 For the erection of a three (3) story structure with decks; for use as a four (4) family dwelling as per approved plans. No bedroom permitted in rear of unit #4 (office only)install drain and water lines from basement to 12 toilets, 12 lavs, 12 tub shower and 4 kitchen sink. The installation will comply with the philadephia plubming code 2004 ![]() ![]() Client: Yuval Llc | Permit type: Plumbing permit | Permit status: Active | Completion date: November 15, 2017 | Permit id: 815223 | |||||
SCORE 89 Complete demolition of existing building by hand. All permitted demolition activity to be in accordance with approved site safety demolition plan & such plan to be maintained on site at all times in accordance with philadelphia administrative code. Full sidewalk closure required as reflected on approved site plan and in accordance with section 3306 of the ibc. Separate street closure permit required prior to start of work. Any deviation will require an amended building permit. ![]() ![]() Client: Yuval Llc | Permit type: Demolition permit | Permit status: Completed | Completion date: December 13, 2016 | Permit id: 723226 | |||||
SCORE 99 For the erection of a three (3) story structure with decks; for use as a four (4) family dwelling as per approved plans. No bedroom permitted in rear of unit #4 (office only) entire building to be sprinkelred per nfpa 13 for exterior wall openings per table 705. 8 of the 2009 ibc separate permit required for any mechanical, electrical, plumbing and fire suppression work. A covered walkway or sidewalk closure shall be required within 9 feet of building facade in accordance with section 3306 of the ibc. Separate building and or streets department permits are required. ![]() ![]() Client: Yuval Llc | Permit type: New construction permit | Permit status: Active | Completion date: October 2, 2017 | Permit id: 697604 | |||||
SCORE 93 Sealing 5" lateral-pa1#20160830947-"self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" ![]() ![]() Client: Yuval Llc | Permit type: Plumbing permit | Permit status: Completed | Completion date: April 20, 2016 | Permit id: 678796 | |||||
SCORE 100 Installation of 400a service and wire throughout for outlet, switches, lights, smokes according to nec code 2008 west district & install fire alarm system throughout according nfpa 72. ![]() ![]() Client: Yuval Llc | Permit type: Electrical permit | Permit status: Active | Completion date: December 12, 2017 | Permit id: 816198 |