Eight exploratory borings will be drilled to a depth of feet below existing ground surface part of a geotechnical investigation using hollow stem auger and split-spoon sampler. Geotechnical sample will be obtained from this borings. Upon completion, the bore holes will be abandoned in accordance with d. C ddoe requirements within 24 hours. The borings diameter will be six inches. Borings will be abandoned with bentonite slurry in accordance with ddoe-wqd requirements -two pounds of bentonite to one-gallon water- within two hour completion. Sealing materials will be introduces at the bottom of the borehole and placed progressively upward to within several inches of ground surface. The remain open portion of the boring will be closed with asphalt cold patch, as per site plans, dc well construction application, dc well schematic form, and work plan report for the bozzuto development company/tenleytown safeway Date: September 11, 2013 Client: Bozzuto Development Company. | Applicant: Rps, Inc. | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300333 | |||||
Re-pipe existing ansul r-102 3-gallon commercial kitchen hood fire suppression system in order to provide proper protection for cooking equipment - hood is existing - safeway #1395 Date: September 12, 2014 Client: Safeway Inc | Applicant: Guardian Fire Protection Services, | Permit type: Alteration and repai | Permit status: Permit issued | Permit id: B1411924 | |||||
SCORE 93 Re-pipe existing ansul r-102 3-gallon commercial kitchen hood fire suppression system in order to provide proper protection for cooking equipment - hood is existing - safeway #1395 Date: September 12, 2014 Contractor: Guardian Fire Protection Services Client: Safeway Inc | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1411924 | |||||
SCORE 100 Eight exploratory borings will be drilled to a depth of feet below existing ground surface part of a geotechnical investigation using hollow stem auger and split-spoon sampler. Geotechnical sample will be obtained from this borings. Upon completion, the bore holes will be abandoned in accordance with d. C ddoe requirements within 24 hours. The borings diameter will be six inches. Borings will be abandoned with bentonite slurry in accordance with ddoe-wqd requirements -two pounds of bentonite to one-gallon water- within two hour completion. Sealing materials will be introduces at the bottom of the borehole and placed progressively upward to within several inches of ground surface. The remain open portion of the boring will be closed with asphalt cold patch, as per site plans, dc well construction application, dc well schematic form, and work plan report for the bozzuto development company/tenleytown safeway Date: September 11, 2013 Contractor: Rps Inc Client: Bozzuto Development Company. | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300333 | |||||
SCORE 89 Eight exploratory borings will be drilled to a depth of feet below existing ground surface part of a geotechnical investigation using hollow stem auger and split-spoon sampler. Geotechnical sample will be obtained from this borings. Upon completion, the bore holes will be abandoned in accordance with d. C ddoe requirements within 24 hours. The borings diameter will be six inches. Borings will be abandoned with bentonite slurry in accordance with ddoe-wqd requirements -two pounds of bentonite to one-gallon water- within two hour completion. Sealing materials will be introduces at the bottom of the borehole and placed progressively upward to within several inches of ground surface. The remain open portion of the boring will be closed with asphalt cold patch, as per site plans, dc well construction application, dc well schematic form, and work plan report for the bozzuto development company tenleytown safeway Date: September 11, 2013 Contractor: Rps, Inc Client: Bozzuto Development Company. | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300333 | |||||
SCORE 93 Re-pipe existing ansul r-102 3-gallon commercial kitchen hood fire suppression system in order to provide proper protection for cooking equipment - hood is existing - safeway #1395 Date: September 12, 2014 Contractor: Guardian Fire Protection Services, Client: Safeway Inc | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1411924 | |||||
SCORE 77 Type of boring: temporary geotechnical soil borings number of borings: 6 depth of borings: ft drilling method: 4. 25 inch hollow stem augers hole diameter: 5 inches abandonment method: tremie grouting with bentonite grout Date: May 20, 2015 Contractor: Schnabel Engineering Poc: Eoin Durc Client: Georgetown Day School Poc: Rahel Rosner Jbg | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1500303 | |||||
SCORE 59 The current proposed phase ii esa environmental sampling and testing investigation will include the use of a geoprobe for one day to perform soil borings (b-1 to b-10) that will be extended to approximate depths of feet, measurable groundwater, or refusal, whichever occurs first. Using decontaminated drilling and sampling equipment, soil samples will be collected on a continuous basis and field screened with a photo-ionization detector (pid) for volatile organic compounds (vocs). In addition, groundwater samples will be collected from two borings, which encounter groundwater, with disposable pvc piping via disposable tubing with a peristaltic pump. Soil investigative derived waste (idw) will be placed in a drum to be left on site until receipt of the environmental laboratory analysis. Assuming laboratory results meet acceptance criteria testing requirements, a vendor will collect and dispose of the drum and contents at a permitted facility. After sample collection, each boring will be Date: July 12, 2017 Contractor: Vimal Jha Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1700342 |