Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Plumbing permit ![]() Permit status: Completed | Permit id: 730881 | |||||
Suppression permit ![]() Permit status: Completed | Permit id: 691282 | |||||
Mechanical permit ![]() Permit status: Completed | Permit id: 732484 | |||||
New construction permit ![]() Permit status: Active | Permit id: 678258 | |||||
Zoning use permit ![]() Permit status: Completed | Permit id: 653673 | |||||
Mechanical permit ![]() Permit status: Active | Permit id: 752227 | |||||
Electrical permit ![]() Permit status: Completed | Permit id: 700646 | |||||
Plumbing permit ![]() Permit status: Active | Permit id: 753720 | |||||
Use permit ![]() Permit status: Completed | Permit id: 226813 | |||||
Plumbing permit ![]() Permit status: Completed | Permit id: 652092 | |||||
Administrative permit ![]() Permit status: Completed | Permit id: 216877 | |||||
Demolition permit ![]() Permit status: Completed | Permit id: 648871 | |||||
Permit for the erection of three (3) attached structures on lot; pilot house access to roof deck; balcony at 2nd floor rear on unit # 2,3,4,5,7,8,9,10,11,14,15,16 and 17; for the modification of unit# 14 to be a "carriage house" unit with drive aisle on first floor level ( entrance drive) for a multi-family household living ( seventeen ( 17) dwelling units with seven(7) accessory garage parking spaces and seven accessory surface parking spaces size and locstion as shown in the application. . ![]() Applicant: Brett Feldman, Esq. | Permit type: Appeal | Permit status: Granted/prov | Completion date: December 7, 2015 | Permit id: 25757 | |||||
SCORE 82 Plumbing construction for a new single family dwelling. 6wc 7lavs 5showers 1ks 1wb pex and pvc. New 3 4" ds 5" lat 4" main drain and 5x4 curb trap and 6" lat ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: May 18, 2017 | Permit id: 753720 | |||||
SCORE 93 Install (2) hvac systems with ductwork. (sfd) ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: May 18, 2017 | Permit id: 775023 | |||||
SCORE 96 Curb trap, fai, main drain & 4" domestic water service pa10162082445 self certification no longer accepted all trenches in excess of 5 ft must have approved shoring at the time of inspection. ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: February 10, 2017 | Permit id: 712208 | |||||
SCORE 96 Storm & sanitary sewer 1" domestic water service, 4" main drain pa201620824453 self certification no longer accepted all trenches in excess of 5 ft must have approved shoring at the time of inspection. 3 wc, 3 lavs, 2-sh, 1 ks, 1 washer box, pex and pvc throughout ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: October 3, 2017 | Permit id: 710509 | |||||
SCORE 96 Storm & sanitary sewer 1" domestic water service, 4" main drain pa201620824453 self certification no longer accepted all trenches in excess of 5 ft must have approved shoring at the time of inspection. 3 wc, 3 lavs, 2 sh, 1 ks, 1 washer box, pex and pvc throughout ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: December 25, 2016 | Permit id: 710514 | |||||
SCORE 96 New 200amp service complete with meter, panel, disconnect & grounding install outlets. Switches, recessed lights,interconned hardwired smokes & co2 detectors, tv ac lines, 4 bath fans & 5 exterior lights as per 2008 nec (north district) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: August 29, 2016 | Permit id: 696574 | |||||
SCORE 100 For the installation of a 1-1 4 inch fire service line for an automatic fire suppression sprinkler system with a backflow prevention assembly in accordance with nfpa 13r ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: December 8, 2016 | Permit id: 720060 | |||||
SCORE 97 For the erection of a four story building for use as a single family dwelling with a roof deck accessed by a roof deck access structure. Building to be fully sprinklered. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Amended permit required for special inspections. Separate permits required for mechanical, electrical, plumbing and fire suppression work. Please see ap#669775 for approved plans and documentation. ![]() ![]() Permit type: New construction permit | Permit status: Completed | Completion date: October 3, 2017 | Permit id: 678251 | |||||
SCORE 100 Underslab only no connection house drain (sfd) ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: January 16, 2017 | Permit id: 693779 | |||||
SCORE 100 For the installation of an automatic fire suppression system throughout a single-family dwelling (unit 8) in accordance with nfpa 13r standards. System to be serviced via a 1-1 2" fire service main line, and is equipped with a backflow prevention assembly. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: August 29, 2016 | Permit id: 694034 | |||||
SCORE 96 Site work: exterior plumbing only; sanitary main with a 5 inch latereal, storm(18inch), and four inch private water main with one - one inch domestic water service to a single family dweeling - the installation will compy with the philadelphia plumbing code 2004. ![]() ![]() Permit type: Plumbing permit | Permit status: Active | Completion date: August 16, 2017 | Permit id: 693834 | |||||
SCORE 96 3 toilets,3 lavs,2 showers,1 kitchen sink,1 washer box pex and pvc curb trap and fai pa20162082445 (sfd)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: August 24, 2017 | Permit id: 722210 | |||||
SCORE 100 Install 200amp service with circuit main breaker panel, recessed fixtures,interconnected smoke alarms and co2 detectors,3 phone and 3 cable as per 2008 nec (north district) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: September 5, 2017 | Permit id: 787628 | |||||
SCORE 93 Install (1) hvac system with ductwork. (sfd) ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: November 1, 2016 | Permit id: 714782 | |||||
SCORE 96 200amp overhead service with grounding, meter and panel. 40-recessed 7- smoke 4-c o 45-switches 70-outlets 6-tv lines doorbell 15-surface lights 4-bath fans as per nec 2008 north district ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: May 18, 2017 | Permit id: 733420 | |||||
SCORE 100 For the installation of an automatic fire suppression system throughout a single-family dwelling (unit 11) in accordance with nfpa 13r standards. System to be serviced via a 1-1 2" fire service main line, and is equipped with a backflow prevention assembly. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: December 6, 2016 | Permit id: 694037 | |||||
SCORE 93 Install (1) hvac system with ductwork. (sfd) ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: June 30, 2017 | Permit id: 775492 | |||||
SCORE 100 Underslab only no connections house drain - the installation will comply with the philadephia plubming code 2004 ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: January 16, 2017 | Permit id: 693499 | |||||
SCORE 100 House drain - under only no connections ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: January 16, 2017 | Permit id: 693134 | |||||
SCORE 100 Install 3 toilets, 3 lavs, 2 shower, 1 kitchen sink and 1 laundry. The installation will comply with the philadephia plubming code 2004 ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: December 25, 2016 | Permit id: 692634 | |||||
For the complete demolition of an existing semi-detached one (1) story commercial building by hand methods. All permitted demolition activity to be in accordance with approved site safety demolition plan & such plan to be maintained on site at all times in accordance with code bulletin b-1302. Partial sidewalk closure required as reflected on approved site plan and in accordance with section 3306 of the ibc. Separate street closure permit required prior to start of work. Any deviation will require an amended building permit. 21 day posting waived due to zba case 25757 on permit 621056 ![]() Permit type: Demolition permit | Permit status: Completed | Completion date: February 19, 2016 | Permit id: 648871 | |||||
Use to adult training and sheltered workshop for adults with intellectual disabilities ![]() Permit type: Use permit | Permit status: Completed | Completion date: July 16, 2009 | Permit id: 226813 | |||||
Documentation for existing adult day training and sheltered workshop. Prior records and folder, existing co not available. No signs this application. ![]() Permit type: Administrative permit | Permit status: Completed | Completion date: August 17, 2009 | Permit id: 216877 | |||||
For the erection of three (3) attached structures on lot; pilot house access to roof deck; balcony at 2nd floor rear for a multi-family household living ( seventeen ( 17) dwelling units with two(2) car garage parking spaces from unit # 2 thru unit # 11 and from unit# 15 thru 17; one(1) car parking garage on unit # 12 thru unit# 14 and no garage p ![]() Permit type: Zoning/use permit | Permit status: Completed | Completion date: December 15, 2015 | Permit id: 644587 | |||||
SCORE 100 Sprinkler system install w. One & one-half (1 1 2") inch fire service & backflor prevention (bfp) assembly for a four (4) story above grade plane, w. Rooftop structure, single-family dwelling. Sprinkler system install per nfpa 13r. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: September 12, 2017 | Permit id: 720031 | |||||
SCORE 96 Install recessed lights,4 c o,5 smokes, outlets,5 bath fans,3 outside lights,2 outside outlets,6 tv lines,dedicated dishwasher line,garbage disposal,heater and a c lines and 200amp service per 2008 nec (sfd)north district ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: December 7, 2016 | Permit id: 700649 | |||||
SCORE 96 Combo water serv, lat, md, ct & fai pa1# 2016-1542373self certification no longer accepted all trenches in excess of 5 ft must have approved shoring at the time of inspection. 3wcs 3lavs 2 shs and 1 kit sink 1 gd, dw 1 washer the installation will comply with the philadelphia plumbing code 2004 ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: January 16, 2017 | Permit id: 705474 | |||||
SCORE 82 Plumbing construction for a new single family dwelling. 3 toilets, 3 lavs, 2 showeres, 1 washer box, 1 kitchen, sink, pex and pvc throughout. 3 4" domestic water service. 5" lateral,4" main drain and 5x4 curb trap3 toilets, 3 lavs, 2 showeres, 1 washer box, 1 kitchen, sink, pex and pvc throughout. ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: April 6, 2017 | Permit id: 730915 | |||||
SCORE 82 Plumbing construction for a new single family dwelling. 3 toilets, 3 lavs, 2 showeres, 1 washer box, 1 kitchen, sink, pex and pvc throughout. 3 4" domestic water service. 5" lateral,4" main drain and 5x4 curb trap ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: February 5, 2017 | Permit id: 730914 | |||||
SCORE 100 200amp service with 40-ckts main breaker panel, 40-recessed fixtures, interconnected smoke & co detectors, 3-phone & cable jacks & all wiring as per nec 2008 (sfd) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: July 25, 2017 | Permit id: 780048 | |||||
SCORE 93 For the installation of pvc drain lines pex water lines, 3 water closet, 3 lavs, 2 tub shower, 1 kitchen sink, 1 laundry, 1 dishwasher and water heater. The installation will comply with the philadephia plubming code 2004 ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: June 29, 2017 | Permit id: 782182 | |||||
SCORE 100 For the installation of an automatic fire suppression system throughout a single-family dwelling (unit 10) in accordance with nfpa 13r standards. System to be serviced via a 1-1 2" fire service main line, and is equipped with a backflow prevention assembly. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: October 3, 2017 | Permit id: 694036 | |||||
SCORE 100 For the installation of a 13r fire supression system for a single family dwelling serviced by a 1-1 2 inch fire service line with a back flow preventer assembly. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Fire suppression system to be installed in accordance with nfpa 13r. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: April 6, 2017 | Permit id: 724786 | |||||
SCORE 96 Install recessed lights,4 c o,5 smokes, outlets,5 bath fans,3 outside lights,2 outside outlets,6 tv lines,dedicated dishwasher line,garbage disposal,heater and a c lines and 200amp service w meter and grounding per 2008 nec (sfd)north district ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: August 17, 2017 | Permit id: 700645 | |||||
SCORE 100 For the installation of a 13r fire supression system for a three family dwelling serviced by a 1-1 2 inch fire service line with a back flow preventer assembly. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Fire suppression system to be installed in accordance with nfpa 13r. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: June 30, 2017 | Permit id: 718653 | |||||
SCORE 97 For the erection of a four story building for use as a single family dwelling with a roof deck accessed by a roof deck access structure. Building to be fully sprinklered. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Amended permit required for special inspections. Separate permits required for mechanical, electrical, plumbing and fire suppression work. Please see ap#665938 for approved foundation plans and documentation. ![]() ![]() Permit type: New construction permit | Permit status: Completed | Completion date: May 18, 2017 | Permit id: 669775 | |||||
SCORE 97 For the installation of a foundation system for 17 townhomes, all work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Separate permit required for new construction of structure and separate permits required for mechanical, electrical, plumbing and fire suppression work. ![]() ![]() Permit type: New construction permit | Permit status: Completed | Completion date: July 31, 2017 | Permit id: 665938 | |||||
For the complete demolition of an existing structure. Size and location as shown in application. For use to vacant lot. ![]() Permit type: Zoning/use permit | Permit status: Completed | Completion date: November 25, 2015 | Permit id: 653673 | |||||
SCORE 93 Sealing lateral pa20153170929 "self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: January 16, 2017 | Permit id: 652092 | |||||
SCORE 100 For the installation of an automatic sprinkler system with a one and a quarter (1-1 4) inch backflow prevention assembly with one and a half (1-1 2) inch fire service main to serve a four (4) story above grade plane structure, with a garage and roof deck. Structure for use as a single-family dwelling. Automatic sprinkler system installation in accordance with nfpa 13r. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: August 28, 2017 | Permit id: 691283 | |||||
SCORE 100 For the installation of an automatic fire suppression system throughout a single-family dwelling (unit 7) in accordance with nfpa 13r standards. System to be serviced via a 1-1 2" fire service main line, and is equipped with a backflow prevention assembly. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: August 29, 2016 | Permit id: 691282 | |||||
SCORE 100 For the installation of an automatic fire suppression system throughout a single-family dwelling (unit 9) in accordance with nfpa 13r standards. System to be serviced via a 1-1 2" fire service main line, and is equipped with a backflow prevention assembly. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: August 29, 2016 | Permit id: 694035 | |||||
SCORE 82 5 toilets, 5 lavs, 4 showers, 1 kitchen sink, 1 washer box, pex and pvc throughout. 3 4 " domestic water service, 5" lateral, 4" main drain 5x4 curb trap (sfd)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: February 26, 2017 | Permit id: 739704 |