Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Plumbing permit Date: January 8, 2016 Permit status: Completed | Permit id: 662531 | |||||
New construction permit Date: March 21, 2014 Permit status: Active | Permit id: 506526 | |||||
Zoning/use permit Date: December 6, 2012 Permit status: Completed | Permit id: 435874 | |||||
Electrical permit Date: December 10, 2015 Permit status: Completed | Permit id: 657329 | |||||
Mechanical permit Date: December 15, 2015 Permit status: Completed | Permit id: 658443 | |||||
Zoning use permit Date: December 6, 2012 Permit status: Completed | Permit id: 435874 | |||||
SCORE 100 For the erection of a new (3) story sfd with crawl space, rear decks at ground and second floor, pilot house and roof deck. Date: March 21, 2014 Contractor: Green Construction Concepts Ll Permit type: New construction permit | Permit status: Completed | Completion date: May 8, 2017 | Permit id: 506526 | |||||
SCORE 96 Install 2 amp service outlets, 15 switches, 25 light fixtures 7-120v interconnected smoke detectors per 2008 nec (sfd)north district Date: December 10, 2015 Contractor: Sfb Wiring Systems Llc Permit type: Electrical permit | Permit status: Completed | Completion date: June 23, 2016 | Permit id: 657329 | |||||
For the erection of (12) attached, three story, sfds with pilot house and roof decks and interior parking stalls. Date: December 6, 2012 Permit type: Zoning/use permit | Permit status: Completed | Completion date: December 6, 2012 | Permit id: 435874 | |||||
SCORE 100 Install (2) hvac systems with ductwork (sfd) Date: December 15, 2015 Contractor: Talgar Inc Permit type: Mechanical permit | Permit status: Completed | Completion date: November 1, 2016 | Permit id: 658443 | |||||
SCORE 100 1" water service,ct,5" lateral,3 wc,3 vanity,3 bath tubs,1 ktichen sink and washer box pa20160080723(sfd)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" Date: January 8, 2016 Contractor: Tommys Plumbing Permit type: Plumbing permit | Permit status: Completed | Completion date: January 16, 2017 | Permit id: 662531 | |||||
SCORE 100 Repairing 5" sewer lateral pa20161931079 (sfd)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" Date: July 11, 2016 Contractor: Tommys Plumbing Permit type: Plumbing permit | Permit status: Completed | Completion date: January 16, 2017 | Permit id: 706252 | |||||
Administrative permit Date: April 22, 2016 Permit status: Active | Permit id: 676297 | |||||
Suppression permit Date: April 29, 2016 Permit status: Active | Permit id: 659822 | |||||
Suppression permit Date: April 29, 2016 Client: Leingang Andrew Davis Jory | Permit status: Completed | Permit id: 659822 | |||||
Administrative permit Date: April 22, 2016 Client: Leingang Andrew Davis Jory | Permit status: Completed | Permit id: 676297 | |||||
Amending bldg permit #506526 to reflect revised partition location for basement at 2nd floor. Revised roof framing and rear decks. Date: April 22, 2016 Client: Leingang Andrew Davis Jory | Permit type: Administrative permit | Permit status: Completed | Completion date: December 8, 2016 | Permit id: 676297 | |||||
SCORE 86 To resolve l+i case# 526706 to install an automatic sprinkler system w. One (1) inch combined fire & domestic service line to serve previously approved three (3) story above grade plane, rooftop structure & crawlspace, residential building (townhouse). Automatic sprinkler system installation in accordance with nfpa 13d. Date: April 29, 2016 Contractor: Dc Inferno Client: Leingang Andrew Davis Jory | Permit type: Suppression permit | Permit status: Completed | Completion date: December 8, 2016 | Permit id: 659822 |