Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Zoning use permit Date: March 23, 2016 Client: University City Science Center | Client Company: Attn: Curt Hess | Permit status: Completed | Permit id: 674790 | |||||
Electrical permit Date: January 4, 2017 Client: University City Science Center | Client Company: Attn: Curt Hess | Permit status: Active | Permit id: 746312 | |||||
Plumbing permit Date: December 14, 2016 Client: University City Science Center | Client Company: Attn: Curt Hess | Permit status: Active | Permit id: 737527 | |||||
New construction permit Date: August 8, 2016 Client: University City Science Center | Client Company: Attn: Curt Hess | Permit status: Active | Permit id: 680231 | |||||
On 04 27 2016, the department of licenses and inspections issued a notice of refusal for application #663786. Date: May 10, 2016 Client: University City Science Center | Client Company: Attn: Curt Hess | Applicant: Neil Sklaroff, Esquire | Permit type: Appeal | Permit status: Approved | Completion date: July 25, 2016 | Permit id: 27806 | |||||
SCORE 100 New construction: exterior plumbing for a (14) story high rise business, professional offices, & research building with future retail restaurant on the ground floor. The installation includes a 12"storm sewer lateral with cistern, 6" domestic water distribution service, a 15" sanitary sewer lateral and a 10" sanitary sewer lateral to the street mains. An additional permit is required for the 6" backflow prevention containment assembly on the main domestic water supply. Date: December 14, 2016 Contractor: Harry Stuhl Iii Permit type: Plumbing permit | Permit status: Active | Completion date: November 22, 2017 | Permit id: 737527 | |||||
SCORE 100 New construction:interior plumbing;fourteen (14) story structure with penthouse -the installation shall comply with the philadelphia plumbing code, 2004 Date: April 17, 2017 Contractor: E J Raith Mechanical Inc Permit type: Plumbing permit | Permit status: Expired | Completion date: May 15, 2017 | Permit id: 767751 | |||||
SCORE 96 Amend building permit ap#742034, to include a certificate of occupancy for the 1st floor level lobby and service area. Certificate of occupancy not to include commercial retail spaces. Date: March 28, 2017 Contractor: Intech Construction Llc Permit type: Administrative permit | Permit status: Active | Completion date: October 27, 2017 | Permit id: 770007 | |||||
Amend permit #742034 for the erection of foundation, operation, and dis-assembly of tower crane. Street closure permits required prior to erection of crane. The erection, use and inspection of the tower crane shall be in conformance with the approved plans and title 9 chapter 9-33 of the philadelphia code. All work shall be done in accordance with streets dept. Approval. Date: May 26, 2017 Permit type: Administrative permit | Permit status: Expired | Completion date: June 1, 2017 | Permit id: 780811 | |||||
For the erection of an attached structure with a roof deck at the 3rd floor level. Size and location as shown on plans application. For use as three (3) vacant retail spaces (use registration permit required prior to occupancy), business and professional office and research and development with four (4) off-street loading spaces and thirty-seven (37) class 1 bicycle parking spaces. No signs on this application. See a p no 645180. Date: March 23, 2016 Permit type: Zoning/use permit | Permit status: Completed | Completion date: August 15, 2017 | Permit id: 674790 | |||||
SCORE 56 For the erection of drilled shafts foundation system bearing on weather rock foundation system as per approved geotechnical report and foundation plans. All work shall be in accordance with drilled shaft recommendations. Foundation system for a future high rise structure. Amended building permit required for statement of special inspection schedule, duties and responsibilities agreement form, qualified special inspectors Date: August 8, 2016 Contractor: Intech Perryman Joint Venture Permit type: New construction permit | Permit status: Expired | Completion date: June 1, 2017 | Permit id: 680231 | |||||
SCORE 96 For the erection of a fourteen (14) story structure with penthouse with mezzanine as per approved plans. This permit is for core and shell. Separate permit required for fitout permits. Fire command center approval per fire department creation of new streets per philadelphia streets dept. Approval see bbs case variance 27806 for sprinkler requirement. Separate permit required for any mep and fire suppression work. Date: February 24, 2017 Contractor: Intech Construction Llc Permit type: New construction permit | Permit status: Active | Completion date: August 31, 2017 | Permit id: 742034 | |||||
Prelim as per plans Date: March 17, 2017 Permit type: Administrative permit | Permit status: Completed | Completion date: March 17, 2017 | Permit id: 663786 | |||||
SCORE 100 Temporary service installation per attached prints at construction of building. Date: January 4, 2017 Contractor: Charles H Macdonald Electric I Permit type: Electrical permit | Permit status: Active | Completion date: July 24, 2017 | Permit id: 746312 | |||||
SCORE 100 For the installation of a new hvac mechanical system at core spaces to include hydronic piping, boilers, electric water-cooled chillers, cooling tower installation, unit heaters, air handlers, grilles registers diffusers, exhaust subducts, associated ductwork, and associated fire smoke dampers. Separate permits required for mechanical fit-out of tenant spaces at upper levels, smoke control system installation, fuel tank installation and associated fuel gas piping. Date: March 31, 2017 Contractor: Tracey Mechanical Inc Permit type: Mechanical permit | Permit status: Active | Completion date: November 30, 2017 | Permit id: 748044 |