To amend permit number b1213798, to include havc equipment. ![]() Client: Potomac Electric Power Company | Applicant: Douglas Foster | Permit type: Addition alteration | Permit status: Completed | Permit id: B1300497 | |||||
Alteration and repair of existing 15,9 sf of office space at 2nd floor. Including new drywall partitions, doors, carpet, paint, ceilings, light fixtures, and electrical, plumbing and mechanical upgrades. ![]() Client: Genet Ketsela Pepco Holdings, Inc. | Applicant: Genet Ketsela Pepco Holdings, Inc.; Barbara Laurie Devrouax + Purnell Architects | Permit type: Alteration and repai | Permit status: Completed | Permit id: B1213798 | |||||
Aecom , enviromental consultant for pepco, will be hand augering to a depth no greater than 4ft , below grade surface. Soil samples will be collected to precharacterize site conditions prior to deconstruction activites. The type of well being installed will be a soil boring. The diameter of the boring will be 6 inches and the total number of borings is26. Soil cutting will be containerized in a labeled non-hazardfous 55 gallon drum. Borings will be filled with with a hydrated bentonite chips to grade surface. ![]() Client: Potomac Electric Power Company | Applicant: Daniel Hulbert | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1200111 | |||||
After hour permit for rte 295 ? Suitland pkwy to work in the roadway to install a freeze pit and freezing device in conjuction with public space permit pa73859 ![]() Client: Pepco | Applicant: Robert Thompson | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300192 | |||||
After hours permit for rte 295 ? Suitland parkway to work in the roadway for the purpose to install a freeze pit ? Freezing device conjuction with public space permit pa73859 ![]() Client: Pepco Pepco | Applicant: Robert Thompson | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300072 | |||||
Demolition of 9 above ground water tanks asts: 4 - distilled water -demineralizer 3 - regeneration waste -water treatment 2- ash settlement ![]() Client: Pepco Energy Services | Applicant: Michael Williams | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1300020 | |||||
Remove one 20,0 gallon un-leaded gasoline ust and two gasoline dispensers, as per site plans. ![]() Applicant: Potomac Electrical Power Company; Rapid Permit Service, Inc. | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1200086 | |||||
Repair to existing stack vitilizing scaffolding ![]() Client: Potomac Electric Power Company | Applicant: Michael Williams | Permit type: Alteration and repai | Permit status: Permit issued | Permit id: B1203366 | |||||
Installation of concrete foundations for new transformer, one lv station service transformer, utility shed, and foundation with containment for our ystem spare transformer and associated work. ![]() Client: Potomac Electric Power Company | Applicant: Adrienne W. Sheffield | Permit type: Alteration and repai | Permit status: Permit issued | Permit id: B1110625 | |||||
Removal of fire pump from plant and installation of same fire pump in fire pump house. ![]() Client: Potomac Electric Power Company | Applicant: Michael Williams | Permit type: Alteration and repai | Permit status: Permit issued | Permit id: B1301788 | |||||
Electrical ![]() Client: Potomac Electric Power Company | Applicant: Stephen J. Adams | Permit status: Completed | Permit id: E1203190 | |||||
This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeildswyu%2f5xbcdxkhxhelegx5 ![]() Client: Pepco Holdings, Inc. | Applicant: Laurie Weisman; Pepco Holdings, Inc.; Paul Thieberger | Permit type: Plumbing and gas | Permit status: Completed | Permit id: P53865063 | |||||
Inerior renovation ![]() Client: Potomac Electric Power Company | Applicant: Edwin L Hancock | Permit type: Mechanical | Permit status: Completed | Permit id: M1200912 | |||||
Removal and replace wheelchair lift ![]() Client: Pepco | Applicant: Stevens | Permit type: Addition alteration | Permit status: Permit issued | Permit id: B1402345 | |||||
Replacing 5 existing generator with new, install 5 new automatic transfer switches, upgrade electrical service to new generators in buildings 54, 56, 59, 75 ? 88 ![]() Client: Pepco | Applicant: Sherri R Permit Service, Llc | Permit type: Alteration and repai | Permit status: Permit issued | Permit id: B1311365 | |||||
Erosion and sediment control permit for existing demoliton permit ![]() Client: Pepco Pepco | Applicant: John Wortmann Amt Llc | Permit type: Demolition | Permit status: Permit issued | Permit id: D1400046 | |||||
Renewal of demolition permit #d1100362 which expired 7/01/2012 - demolish cooling towers in power plant - owners are de-commissioning the plant ![]() Client: Pepco Energy Services | Applicant: A2z Environmental Group | Permit type: Demolition | Permit status: Permit issued | Permit id: D1300361 | |||||
Demolition of 4 above ground storage tanks ast. 3- 4 oil tanks 1- 2 oil tank ![]() Client: Pepco Energy Services | Applicant: A2z Environmental Group | Permit type: Demolition | Permit status: Permit issued | Permit id: D1300197 | |||||
Demolition of two installed foam supression systems. ![]() Client: Pepco Energy Services | Applicant: A2z Environmental Group, Llc. | Permit type: Demolition | Permit status: Permit issued | Permit id: D1300229 | |||||
Work includes accessing manholes 3 to 13 located in benning rd ne, h street ne, 3rd street ne and florida ave. Ne to certify the existing manholes and pull cables. ![]() Client: Pepco | Applicant: Mousa Hejazi | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300432 | |||||
Excavating a 5x freezing pit over an existing transmission line located behind the curb on suitland pkw aproximately 4 ft east of firth sterling ave to install a freezing device and freeze the existing conduit to install a night cap in adjacent manhole #3 per pa73859-r2 ![]() Client: Pepco | Applicant: Robert Thompson | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300330 | |||||
Install 11 lf of 4 way conduitfor a 69 kv transmission line along benning rd. Between pepco mh #3a located at the intersection of benning rd. And anacostia ave ne per pa 72217-r2 ![]() Client: Pepco | Applicant: Robert Thompson | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300334 | |||||
Digging new pitts as needed to access the existing electric pipe on the pepco transmission line and repair damaged portions of the pipe which are located on the southbound side of suitland pkw beginning on the ramp to i 295 southbound per pa78829 ![]() Client: Pepco | Applicant: Robert Thompson | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300332 | |||||
Work includes accessing existing mh #2 located on 10th sst. Nw between v st and w st., mh #3 located on 9th st nw between westminster st and t st., mh #4 located on 9th st. Nw between o st. And p st., mh #5 located on o st. Nw between 5th st. And new jersey ave., mh #6 located on new jersey ave. Nw between l st. And pierce st. And #7 located on new jersey ave. Nw between f st. And g st. On existing pepco transmission line ![]() Client: Pepco | Applicant: Mousa Hejazi | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300403 | |||||
Excavating a 5 x freeze pit over existing transmission lines located behind the curb on suitland pkwy approximately 4 east of firth sterling ave to inatall a freezing devise and freeze existing conduit to install a night cap in adjacent mh 3 per pa 73859 ? Pa10074023 ![]() Client: Pepco | Applicant: Robert Thompson | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300255 | |||||
Proposed work includes accessing mh 1a located in s street sw between half st. And 1st street and also accessing mh located in v street sw between 1st street and half street in order to remove existing cables and re certifing the conduits pull new cables and splice them permit pa 73452 ? Pa 10081408. No work will be done on 1/21/2013 under thie permit ![]() Client: Pepco | Applicant: Robert Thompson | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300256 | |||||
Pepco permit pa72217-r2 to install approximatley 11 lf of 4 way conduit along benning rd. Ne between pepco mh 3a at the intersection of benning rd. And anacostia ave to mh 4a located on the inbound lane of benning rd. Ne. No work will be done on 1/21/2013 under this permit ![]() Client: Pepco | Applicant: Robert Thompson | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300257 | |||||
Work includes excavating an approximately ft x 5 ft pit in benning road ne inbound about 32 ft west of its intersection with oklahoma ave. Ne in order to repair the damaged portion of a transmission line conduit ![]() Client: Pepco | Applicant: Stantec | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300873 | |||||
The work consist on drilling geoprobe soil borings 2. 25 inches diameter by 25 feet deep and 6 geotechnical sampling 9 inches by 1 feet deep. 25 surface soil samples will also be collected using a hand auger/hand shovel. Drilling methods for the geoprobe it will be direct push and for the geotechnical it will be hollow stem augers. As per site plans, work plan report, dc well construction form and dc well schematic form for pepco. ![]() Client: Pepco - Pepco Energy Services. | Applicant: Luis Garcia-Rapid Permit Service, Inc. | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300069 | |||||
Removal of two 40 gallon oily water diesel fuel underground storage tanks ![]() Client: Pepco Energy Services | Applicant: Pepco Energy Services; A2z Environmental Group, Llc | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1300028 | |||||
Aecom, environmental consultant for pes, will be hand augering to a depth no greater than 24 inchest below grade surface. Soil samples will be collected to precharacterize site conditions prior to deconstruction activities. The diameter of the boring will be 6 inches and the total number of borings is 12. Soil cuttings will be containerized in a labeled non-hazardous 55-gallon drum. Borings will be filled with a hydrated bentonite chips to grade surface ![]() Client: Pepco Energy Services - Michael Williams | Applicant: Aecom - Kevin Yue | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300284 | |||||
Pepco energy service- pump houses and two clarifer ![]() Client: Potomac Electric Power Company | Permit type: Raze | Permit status: Permit issued | Permit id: R1300073 | |||||
Plumbing and gas ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1400236 | |||||
Type of elevator : one (1) vertical wheel chair lift/steel ![]() Client: Potomac Electric Power Company | Applicant: Bedco Mobility Inc | Permit type: Elevator - new | Permit status: Permit issued | Permit id: En1400553 | |||||
This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeildtifpbizd321q%2bu6ct9ymv ![]() Client: Potomac Electric Power Company | Applicant: Amanda Guevara; Potomac Electri Power Company; Mark Brew | Permit type: Plumbing and gas | Permit status: Completed | Permit id: P50094275 | |||||
This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeileejjbwt8kjdf8lj2bm9w3r ![]() Client: Barbara Laurie | Applicant: Troy Tipton; Barbara Laurie; George Hockaday-Bey | Permit type: Electrical | Permit status: Completed | Permit id: E66288547 | |||||
Demolition work for interior renovation. ![]() Client: Potomac Electric Power Company | Applicant: Spurge Eismeier/permits By Pinecrest | Permit type: Demolition | Permit status: Permit issued | Permit id: D1400649 | |||||
14 pairs of nested groundwater monitoring wells will be installed: 28 wells total at 14 locations. The wells will be installed by the sonic drilling method. The wells will be constructed of 2-inch diameter pvc, and the maximum well depth will be feet below grade. ![]() Client: Pepco | Applicant: Aecom | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400431 | |||||
Due to a breach of the wmata tunnel beneath the pepco property at 34 benning road ne, washington, dc, a cement grouting program is required to stabilize the subsurface soils in the area of the breach. Between 9 and 33 soil borings no deeper than 55 ft and no wider than 6 inches in diameter will be installed within a 50x1 ft area to pump grout below the tunnel to fill any void space and densify the surrounding soils. Borings will be immediately abandoned with cement grout. Work is being done under the direction of wmata. ![]() Client: Pepco | Applicant: Aecom / Hb Permit | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400347 | |||||
Two temporary construction trailers, trailer 1: 64 x 36, trailer 2: 66 x 48, 1 floor, trailers to be used during construction of adjacent building ![]() Client: Potomac Electric Power Company | Applicant: The Whiting-Turner Contracting Comp | Permit type: New building | Permit status: Permit issued | Permit id: B1407596 | |||||
To raze a power plant building. ![]() Client: Potomac Electric Power Company | Permit type: Raze | Permit status: Permit issued | Permit id: R1400089 | |||||
Electrical ![]() Client: Potomac Electric Power Company | Applicant: Paul M. Kolb | Permit status: Completed | Permit id: E1500272 | |||||
This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeilf5fuagk4tvgm2llvkt185v ![]() Client: Pepco Pepco | Applicant: Daryl Stevens; Pepco Pepco; Daryl Stevens | Permit type: Electrical | Permit status: Permit issued | Permit id: E29460317 | |||||
This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeilfgpd3evduxppy7o%2fqyqoqy ![]() Client: Pepco Pepco | Applicant: Daryl Stevens; Pepco Pepco; Daryl Stevens | Permit type: Electrical | Permit status: Permit issued | Permit id: E51138595 | |||||
This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeileoho4t6mhfhnzmrtx5y%2f%2bi ![]() Client: Pepco Holding, Inc. | Applicant: Alexander Kim; Pepco Holding, Inc.; Uwe Neumann | Permit type: Mechanical | Permit status: Completed | Permit id: Ar51860611 | |||||
This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeilez4nmv%2b8uhio6raubazljd ![]() Client: Pepco Pepco | Applicant: Adolphus Simmons; Pepco Pepco; Adolphus Simmons | Permit type: Plumbing and gas | Permit status: Completed | Permit id: P91973121 | |||||
Interior renovation work to an existing office space. ![]() Client: Potomac Electric Power Company | Applicant: Spurge Eismeier/permits By Pinecrest | Permit type: Alteration and repai | Permit status: Completed | Permit id: B1409780 | |||||
Remove & replace the existing diesel fire pump with a new electric fire pump. ![]() Client: Pepco Holdings | Applicant: David Dupree Strickland Fire Protection, Inc. | Permit type: Alteration and repai | Permit status: Permit issued | Permit id: B1501204 | |||||
SCORE 56 Alteration and repair of existing 15,9 sf of office space at 2nd floor. Including new drywall partitions, doors, carpet, paint, ceilings, light fixtures, and electrical, plumbing and mechanical upgrades. ![]() Client: Genet Ketsela Pepco Holdings, Inc. | Permit type: Alteration and repair | Permit status: Completed | Permit id: B1213798 | |||||
SCORE 56 Remove one 20,0 gallon un-leaded gasoline ust and two gasoline dispensers, as per site plans. ![]() Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1200086 | |||||
SCORE 82 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: E1203190 | |||||
SCORE 81 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: E1203230 | |||||
SCORE 86 Mechanical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: M1300170 | |||||
Plumbing and gas ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: P1202754 | |||||
SCORE 92 Plumbing and gas ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1301621 | |||||
SCORE 90 Plumbing and gas ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1300873 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeildswyu%2f5xbcdxkhxhelegx5 ![]() Client: Pepco Holdings, Inc. | Permit type: Plumbing and gas | Permit status: Completed | Permit id: P53865063 | |||||
Pepco energy service- pump houses and two clarifer ![]() Client: Potomac Electric Power Company | Permit type: Raze | Permit status: Permit issued | Permit id: R1300073 | |||||
SCORE 86 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: E1308751 | |||||
Plumbing and gas ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1400236 | |||||
To raze a power plant building. ![]() Client: Potomac Electric Power Company | Permit type: Raze | Permit status: Permit issued | Permit id: R1400089 | |||||
SCORE 96 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: E1500272 | |||||
SCORE 96 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: E1501239 | |||||
Electrical ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: E1501393 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeileoho4t6mhfhnzmrtx5y%2f%2bi ![]() ![]() Client: Pepco Holding, Inc. | Permit type: Mechanical | Permit status: Completed | Permit id: Ar51860611 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeilez4nmv%2b8uhio6raubazljd ![]() ![]() Client: Pepco Pepco | Permit type: Plumbing and gas | Permit status: Completed | Permit id: P91973121 | |||||
SCORE 86 Demolition work for interior renovation. ![]() ![]() Client: Potomac Electric Power Company | Permit type: Demolition | Permit status: Permit issued | Permit id: D1400649 | |||||
SCORE 86 Interior renovation work to an existing office space. ![]() ![]() Client: Potomac Electric Power Company | Permit type: Alteration and repair | Permit status: Completed | Permit id: B1409780 | |||||
SCORE 59 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeilfgpd3evduxppy7o%2fqyqoqy ![]() ![]() Client: Pepco Pepco | Permit type: Electrical | Permit status: Permit issued | Permit id: E51138595 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeildtifpbizd321q%2bu6ct9ymv ![]() Client: Potomac Electric Power Company | Permit type: Plumbing and gas | Permit status: Completed | Permit id: P50094275 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeileoho4t6mhfhnzmrtx5y%2f%2bi ![]() ![]() Client: Pepco Holding, Inc. | Permit type: Mechanical | Permit status: Completed | Permit id: Ar51860611 | |||||
SCORE 86 Replacing 5 existing generator with new, install 5 new automatic transfer switches, upgrade electrical service to new generators in buildings 54, 56, 59, 75 ? 88 ![]() ![]() Client: Pepco | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1311365 | |||||
SCORE 59 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeilf5fuagk4tvgm2llvkt185v ![]() ![]() Client: Pepco Pepco | Permit type: Electrical | Permit status: Permit issued | Permit id: E29460317 | |||||
SCORE 82 The work consist on drilling geoprobe soil borings 2. 25 inches diameter by 25 feet deep and 6 geotechnical sampling 9 inches by 1 feet deep. 25 surface soil samples will also be collected using a hand auger/hand shovel. Drilling methods for the geoprobe it will be direct push and for the geotechnical it will be hollow stem augers. As per site plans, work plan report, dc well construction form and dc well schematic form for pepco. ![]() ![]() Client: Pepco - Pepco Energy Services. | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300069 | |||||
SCORE 82 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: E1203190 | |||||
SCORE 56 Removal of two 40 gallon oily water diesel fuel underground storage tanks ![]() Client: Pepco Energy Services | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1300028 | |||||
SCORE 82 Demolition of two installed foam supression systems. ![]() ![]() Client: Pepco Energy Services | Permit type: Demolition | Permit status: Permit issued | Permit id: D1300229 | |||||
SCORE 56 Remove one 20,0 gallon un-leaded gasoline ust and two gasoline dispensers, as per site plans. ![]() Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1200086 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeileejjbwt8kjdf8lj2bm9w3r ![]() ![]() Client: Barbara Laurie | Permit type: Electrical | Permit status: Completed | Permit id: E66288547 | |||||
SCORE 86 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: E1308751 | |||||
Plumbing and gas ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1400236 | |||||
Pepco energy service- pump houses and two clarifer ![]() Client: Potomac Electric Power Company | Permit type: Raze | Permit status: Permit issued | Permit id: R1300073 | |||||
SCORE 56 Removal of two 40 gallon oily water diesel fuel underground storage tanks ![]() Client: Pepco Energy Services | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1300028 | |||||
SCORE 96 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: E1501239 | |||||
Electrical ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: E1501393 | |||||
SCORE 96 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: E1500272 | |||||
SCORE 56 Alteration and repair of existing 15,9 sf of office space at 2nd floor. Including new drywall partitions, doors, carpet, paint, ceilings, light fixtures, and electrical, plumbing and mechanical upgrades. ![]() Client: Genet Ketsela Pepco Holdings, Inc. | Permit type: Alteration and repair | Permit status: Completed | Permit id: B1213798 | |||||
To raze a power plant building. ![]() Client: Potomac Electric Power Company | Permit type: Raze | Permit status: Permit issued | Permit id: R1400089 | |||||
SCORE 92 Plumbing and gas ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1301621 | |||||
SCORE 90 Plumbing and gas ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1300873 | |||||
Plumbing and gas ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: P1202754 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeildswyu%2f5xbcdxkhxhelegx5 ![]() Client: Pepco Holdings, Inc. | Permit type: Plumbing and gas | Permit status: Completed | Permit id: P53865063 | |||||
SCORE 86 Mechanical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: M1300170 | |||||
SCORE 81 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: E1203230 | |||||
To raze a power plant building. ![]() Client: Potomac Electric Power Company | Permit type: Raze | Permit status: Permit issued | Permit id: R1400089 | |||||
Plumbing and gas ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1701196 | |||||
SCORE 96 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: E1702395 | |||||
SCORE 91 Removal and replace wheelchair lift ![]() ![]() Client: Pepco | Permit type: Addition alteration repair | Permit status: Permit issued | Permit id: B1402345 | |||||
SCORE 56 Erosion and sediment control permit for existing demoliton permit ![]() ![]() Client: Pepco Pepco | Permit type: Demolition | Permit status: Permit issued | Permit id: D1400046 | |||||
SCORE 79 Demolition of 4 above ground storage tanks ast. 3- 4 oil tanks 1- 2 oil tank ![]() ![]() Client: Pepco Energy Services | Permit type: Demolition | Permit status: Permit issued | Permit id: D1300197 | |||||
SCORE 100 Excavating a 5x freezing pit over an existing transmission line located behind the curb on suitland pkw aproximately 4 ft east of firth sterling ave to install a freezing device and freeze the existing conduit to install a night cap in adjacent manhole #3 per pa73859-r2 ![]() ![]() Client: Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300330 | |||||
SCORE 70 Work includes accessing manholes 3 to 13 located in benning rd ne, h street ne, 3rd street ne and florida ave. Ne to certify the existing manholes and pull cables. ![]() ![]() Client: Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300432 | |||||
SCORE 100 Digging new pitts as needed to access the existing electric pipe on the pepco transmission line and repair damaged portions of the pipe which are located on the southbound side of suitland pkw beginning on the ramp to i 295 southbound per pa78829 ![]() ![]() Client: Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300332 | |||||
SCORE 100 Install 11 lf of 4 way conduitfor a 69 kv transmission line along benning rd. Between pepco mh #3a located at the intersection of benning rd. And anacostia ave ne per pa 72217-r2 ![]() ![]() Client: Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300334 | |||||
SCORE 70 Work includes accessing existing mh #2 located on 10th sst. Nw between v st and w st., mh #3 located on 9th st nw between westminster st and t st., mh #4 located on 9th st. Nw between o st. And p st., mh #5 located on o st. Nw between 5th st. And new jersey ave., mh #6 located on new jersey ave. Nw between l st. And pierce st. And #7 located on new jersey ave. Nw between f st. And g st. On existing pepco transmission line ![]() ![]() Client: Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300403 | |||||
SCORE 100 Excavating a 5 x freeze pit over existing transmission lines located behind the curb on suitland pkwy approximately 4 east of firth sterling ave to inatall a freezing devise and freeze existing conduit to install a night cap in adjacent mh 3 per pa 73859 ? Pa10074023 ![]() ![]() Client: Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300255 | |||||
SCORE 89 Work includes excavating an approximately ft x 5 ft pit in benning road ne inbound about 32 ft west of its intersection with oklahoma ave. Ne in order to repair the damaged portion of a transmission line conduit ![]() ![]() Client: Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300873 | |||||
SCORE 56 Aecom, environmental consultant for pes, will be hand augering to a depth no greater than 24 inchest below grade surface. Soil samples will be collected to precharacterize site conditions prior to deconstruction activities. The diameter of the boring will be 6 inches and the total number of borings is 12. Soil cuttings will be containerized in a labeled non-hazardous 55-gallon drum. Borings will be filled with a hydrated bentonite chips to grade surface ![]() ![]() Client: Pepco Energy Services - Michael Williams | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300284 | |||||
SCORE 84 14 pairs of nested groundwater monitoring wells will be installed: 28 wells total at 14 locations. The wells will be installed by the sonic drilling method. The wells will be constructed of 2-inch diameter pvc, and the maximum well depth will be feet below grade. ![]() ![]() Client: Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400431 | |||||
SCORE 56 Due to a breach of the wmata tunnel beneath the pepco property at 34 benning road ne, washington, dc, a cement grouting program is required to stabilize the subsurface soils in the area of the breach. Between 9 and 33 soil borings no deeper than 55 ft and no wider than 6 inches in diameter will be installed within a 50x1 ft area to pump grout below the tunnel to fill any void space and densify the surrounding soils. Borings will be immediately abandoned with cement grout. Work is being done under the direction of wmata. ![]() ![]() Client: Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400347 | |||||
SCORE 62 Two temporary construction trailers, trailer 1: 64 x 36, trailer 2: 66 x 48, 1 floor, trailers to be used during construction of adjacent building ![]() ![]() Client: Potomac Electric Power Company | Permit type: New building | Permit status: Permit issued | Permit id: B1407596 | |||||
SCORE 99 Removal of fire pump from plant and installation of same fire pump in fire pump house. ![]() ![]() Client: Potomac Electric Power Company | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1301788 | |||||
SCORE 99 Repair to existing stack vitilizing scaffolding ![]() ![]() Client: Potomac Electric Power Company | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1203366 | |||||
SCORE 56 Installation of concrete foundations for new transformer, one lv station service transformer, utility shed, and foundation with containment for our ystem spare transformer and associated work. ![]() ![]() Client: Potomac Electric Power Company | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1110625 | |||||
SCORE 99 To amend permit number b1213798, to include havc equipment. ![]() ![]() Client: Potomac Electric Power Company | Permit type: Addition alteration repair | Permit status: Completed | Permit id: B1300497 | |||||
SCORE 56 Alteration and repair of existing 15,9 sf of office space at 2nd floor. Including new drywall partitions, doors, carpet, paint, ceilings, light fixtures, and electrical, plumbing and mechanical upgrades. ![]() Client: Genet Ketsela Pepco Holdings, Inc. | Permit type: Alteration and repair | Permit status: Completed | Permit id: B1213798 | |||||
SCORE 100 After hour permit for rte 295 ? Suitland pkwy to work in the roadway to install a freeze pit and freezing device in conjuction with public space permit pa73859 ![]() ![]() Client: Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300192 | |||||
SCORE 81 Aecom , enviromental consultant for pepco, will be hand augering to a depth no greater than 4ft , below grade surface. Soil samples will be collected to precharacterize site conditions prior to deconstruction activites. The type of well being installed will be a soil boring. The diameter of the boring will be 6 inches and the total number of borings is26. Soil cutting will be containerized in a labeled non-hazardfous 55 gallon drum. Borings will be filled with with a hydrated bentonite chips to grade surface. ![]() ![]() Client: Potomac Electric Power Company | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1200111 | |||||
SCORE 100 After hours permit for rte 295 ? Suitland parkway to work in the roadway for the purpose to install a freeze pit ? Freezing device conjuction with public space permit pa73859 ![]() ![]() Client: Pepco Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300072 | |||||
SCORE 99 Demolition of 9 above ground water tanks asts: 4 - distilled water -demineralizer 3 - regeneration waste -water treatment 2- ash settlement ![]() ![]() Client: Pepco Energy Services | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1300020 | |||||
SCORE 56 Remove one 20,0 gallon un-leaded gasoline ust and two gasoline dispensers, as per site plans. ![]() Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1200086 | |||||
SCORE 81 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: E1203230 | |||||
SCORE 82 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: E1203190 | |||||
SCORE 90 Plumbing and gas ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1300873 | |||||
SCORE 92 Plumbing and gas ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1301621 | |||||
Plumbing and gas ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: P1202754 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https: ospi. Dcra. Dc. Gov ospi printpermit. Aspx? Param=zi8iggjeildswyu%2f5xbcdxkhxhelegx5 ![]() Client: Pepco Holdings, Inc. | Permit type: Plumbing and gas | Permit status: Completed | Permit id: P53865063 | |||||
SCORE 86 Mechanical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: M1300170 | |||||
SCORE 79 Inerior renovation ![]() ![]() Client: Potomac Electric Power Company | Permit type: Mechanical | Permit status: Completed | Permit id: M1200912 | |||||
SCORE 84 Demolition of two installed foam supression systems. ![]() ![]() Client: Pepco Energy Services | Permit type: Demolition | Permit status: Permit issued | Permit id: D1300229 | |||||
SCORE 82 Replacing 5 existing generator with new, install 5 new automatic transfer switches, upgrade electrical service to new generators in buildings 54, 56, 59, 75 ? 88 ![]() ![]() Client: Pepco | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1311365 | |||||
SCORE 82 The work consist on drilling geoprobe soil borings 2. 25 inches diameter by 25 feet deep and 6 geotechnical sampling 9 inches by 1 feet deep. 25 surface soil samples will also be collected using a hand auger hand shovel. Drilling methods for the geoprobe it will be direct push and for the geotechnical it will be hollow stem augers. As per site plans, work plan report, dc well construction form and dc well schematic form for pepco. ![]() ![]() Client: Pepco - Pepco Energy Services. | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300069 | |||||
SCORE 56 Removal of two 40 gallon oily water diesel fuel underground storage tanks ![]() Client: Pepco Energy Services | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ut1300028 | |||||
SCORE 86 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: E1308751 | |||||
Plumbing and gas ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1400236 | |||||
SCORE 86 Demolition work for interior renovation. ![]() ![]() Client: Potomac Electric Power Company | Permit type: Demolition | Permit status: Permit issued | Permit id: D1400649 | |||||
SCORE 86 Interior renovation work to an existing office space. ![]() ![]() Client: Potomac Electric Power Company | Permit type: Alteration and repair | Permit status: Completed | Permit id: B1409780 | |||||
Electrical ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: E1501393 | |||||
SCORE 96 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: E1501239 | |||||
SCORE 96 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Completed | Permit id: E1500272 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https: ospi. Dcra. Dc. Gov ospi printpermit. Aspx? Param=zi8iggjeileoho4t6mhfhnzmrtx5y%2f%2bi ![]() ![]() Client: Pepco Holding, Inc. | Permit type: Mechanical | Permit status: Completed | Permit id: Ar51860611 | |||||
SCORE 83 Provide a storage shed for pepco. See plans for further details. ![]() ![]() Client: Potomac Electric Power Company | Permit type: New building | Permit status: Permit issued | Permit id: B1611590 | |||||
SCORE 82 To occupy one travel lane of benning road ne between anacostia ave ne and oklahoma ave ne from 9pm to 5am. Contractor will close sidewalks for pedestrian safety. In conjunction with approved permit #pa10355326 ![]() ![]() Client: C3m Power Systems | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1700245 | |||||
SCORE 56 Aecom, environmental consultant for pepco, plans to install 291 soil borings at the subject property. Up to 2 samples will be shallow (1 ft deep), installed by hand auger. The remaining borings will be a maximum of feet deep and installed by geoprobe drill rig. Soil boring diameters will be between three to four inches. Boreholes will be abandoned by tremie grouting with bentonite slurry, 2lb of bentonite powder to 1 gallon water, to approximately 1 ft deep and restored to existing surface cover. ![]() ![]() Client: Potomac Electric Power Company | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1700024 | |||||
SCORE 59 Need after hours in conjunction with approved permit pa10229554-r2. To occupy travel lanes of benning road to work on overhead rail tracks ![]() ![]() Client: C3m Power System | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1600914 | |||||
SCORE 82 Need after hours in conjunction with approved permit pa10229554-r3. To occupy travel lane of benning road to work on overhead rail tracks ![]() ![]() Client: C3m Power Systems | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1601008 | |||||
SCORE 82 To temp close the sidewalk and one travel lane to install scaffolding tower and leave tower up for 3 motnhs during construction. In conjunction with permit pa10275256 ![]() ![]() Client: C3m Power Systems | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1600729 | |||||
SCORE 82 Need after hours in conjunction with approved permit #pa10229554-r1. To occupy travel lanes of benning road to work on overhead rail tracks. ![]() ![]() Client: C3m Power Systems | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1600798 | |||||
SCORE 59 Need after hours in conjunction with permit #pa10299732. To temp close the sidewalk and one travel lane to install scaffolding towers ![]() ![]() Client: C3m Power System | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1600799 | |||||
Electrical ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: E1702211 | |||||
SCORE 96 Electrical ![]() ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: E1702395 | |||||
Plumbing and gas ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1701257 | |||||
Plumbing and gas ![]() Client: Potomac Electric Power Company | Permit status: Permit issued | Permit id: P1701196 | |||||
SCORE 59 As per pepcos sip, self implementing remediation plan, agreement with epa and dooe, miller environmental group, inc. Will excavate low level pcb contaminated soils. Pepco will contract for disposal at a certified tsdf. Miller environmental group, inc. Will backfill as per the plans to be submitted. ![]() ![]() Client: Na Miller Environmental Group, Inc. | Permit type: Excavation only | Permit status: Permit issued | Permit id: Ex1600034 | |||||
SCORE 59 Demolition of concrete cooling tower basins @ pepcos benning road facility ![]() ![]() Client: Na Miller Environmental Group, Inc. | Permit type: Demolition | Permit status: Permit issued | Permit id: D1600373 | |||||
SCORE 56 We propose to advance a total of three test borings (b-1 to b-3) at the site. Borings b-1 to b-3 will be advanced to a maximum depth of feet below existing grade. The locations of the proposed borings are shown on the attached figure 1. A proposed well application schematic form is provided and attached to this work plan. Borings b-1to b-3 will be advanced utilizing a truck or track-mounted drill rig. Hollow stem augers (hsa) approximately 2-1 4" td diameter will be advanced maximum depth of feet below existing grade. It is anticipated that boreholes approximately 7 inches in diameter will result from the augering operations ![]() ![]() Client: Potomac Electric Company | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1700146 | |||||
SCORE 82 To occupy one travel lane of benning road ne between anacostia ave and oklahoma ave from 9pm to 5am. ![]() ![]() Client: C3m Power Systems | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1700403 | |||||
SCORE 79 Renewal of demolition permit #d1100362 which expired 7/01/2012 - demolish cooling towers in power plant - owners are de-commissioning the plant ![]() ![]() Client: Pepco Energy Services | Permit type: Demolition | Permit status: Permit issued | Permit id: D1300361 | |||||
SCORE 100 Proposed work includes accessing mh 1a located in s street sw between half st. And 1st street and also accessing mh located in v street sw between 1st street and half street in order to remove existing cables and re certifing the conduits pull new cables and splice them permit pa 73452 ? Pa 10081408. No work will be done on 1/21/2013 under thie permit ![]() ![]() Client: Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300256 | |||||
SCORE 100 Pepco permit pa72217-r2 to install approximatley 11 lf of 4 way conduit along benning rd. Ne between pepco mh 3a at the intersection of benning rd. And anacostia ave to mh 4a located on the inbound lane of benning rd. Ne. No work will be done on 1/21/2013 under this permit ![]() ![]() Client: Pepco | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1300257 | |||||
SCORE 93 Type of elevator : one (1) vertical wheel chair lift/steel ![]() ![]() Client: Potomac Electric Power Company | Permit type: Elevator - new | Permit status: Permit issued | Permit id: En1400553 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeileejjbwt8kjdf8lj2bm9w3r ![]() ![]() Client: Barbara Laurie | Permit type: Electrical | Permit status: Completed | Permit id: E66288547 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeildtifpbizd321q%2bu6ct9ymv ![]() Client: Potomac Electric Power Company | Permit type: Plumbing and gas | Permit status: Completed | Permit id: P50094275 | |||||
SCORE 59 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeilf5fuagk4tvgm2llvkt185v ![]() ![]() Client: Pepco Pepco | Permit type: Electrical | Permit status: Permit issued | Permit id: E29460317 | |||||
SCORE 59 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeilfgpd3evduxppy7o%2fqyqoqy ![]() ![]() Client: Pepco Pepco | Permit type: Electrical | Permit status: Permit issued | Permit id: E51138595 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeilez4nmv%2b8uhio6raubazljd ![]() ![]() Client: Pepco Pepco | Permit type: Plumbing and gas | Permit status: Completed | Permit id: P91973121 | |||||
SCORE 56 Install 67 soil borings to ft deep, 4 inches in diameter, for collection of soil and groundwater samples. Borings will be installed by hand auger and geoprobe drill rig. Borings will be abandoned within 24-hrs by tremie grouting (2 lbs bentonite:1 gal water mix) to 1-ft deep, then restored to existing surface cover. ![]() ![]() Client: Potomac Electric Power Company | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1700388 | |||||
SCORE 62 Remove & replace the existing diesel fire pump with a new electric fire pump. ![]() ![]() Client: Pepco Holdings | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1501204 | |||||
SCORE 62 Remove & replace the existing diesel fire pump with a new electric fire pump. ![]() ![]() Client: Pepco Holdings | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1501204 |