Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
For the erection of an attached, four (4) story structure with a roof deck. For use as vacant commercial on the 1st floor (separate certificate of occupancy reqd) and twelve (12) dwelling units on the 1st through 4th floors and a roof deck for use by the residential units. Separate permits required for plumbing, mechanical, electrical and fire suppression. Per bbs variance (case no 26678): the structure must be sprinklered throughout per nfpa 13, the stair enclosure must have a fire resistance rating of 2 hours, all floor ceiling assemblies must have a fire resistance rating of 2 hours, the fire alarm system shall include an exterior horn and strobe at the roof deck above the 4th story. ![]() Client: Msp Philly I Lp | Permit type: New construction permit | Permit status: Completed | Completion date: August 29, 2017 | Permit id: 683609 | |||||
SCORE 99 Install (14) heat pumps with ductwork. (mixed use) ![]() ![]() Client: Msp Philly I Lp | Permit type: Mechanical permit | Permit status: Completed | Completion date: August 26, 2017 | Permit id: 760437 | |||||
SCORE 100 For the complete demolition of a one-story masonry building damaged by fire. Size and location as shown in plans. For use as a vacant lot. ![]() ![]() Client: Msp Philly I Lp | Permit type: Zoning/use permit | Permit status: Completed | Completion date: May 19, 2014 | Permit id: 536275 | |||||
SCORE 100 For the complete demolition of a one-story structure damaged by fire in accordance with code bulletin b-1302. Mechanical equipment permitted in accordance with site safety plan (to remain on site during demolition). 21-day notice of demolition waived as part of imminently dangerous case. ![]() ![]() Client: Msp Philly I Lp | Permit type: Demolition permit | Permit status: Completed | Completion date: June 25, 2014 | Permit id: 536280 | |||||
To amend a p no 693738 to clarify permit language. Permit to read: for the creation of bicycle parking spaces, a minimum of four (4) class 1a parking spaces located on an accessible route. Any additional bicycle parking spaces do not require a zoning permit. ![]() Client: Msp Philly I Lp | Permit type: Zoning admin review | Permit status: Completed | Completion date: October 24, 2017 | Permit id: 698376 | |||||
SCORE 100 Install new fire suppression system complying with nfpa 13 throughout the building to include 4" main feed, 4" ames 2000ss backflow prevention assembly, fire pump installation complying with nfpa and one (1) standpipe riser complying with nfpa 14 as per approved plans. All work shall be performed by a fire suppression contractor licensed by the city of philadelphia. ![]() ![]() Client: Msp Philly I Lp | Permit type: Suppression permit | Permit status: Completed | Completion date: August 26, 2017 | Permit id: 719559 | |||||
SCORE 100 5" lateral= 5"trap, 5"main drain into building. 1 1 2" water service pa1# 2016-62701899 "self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" ![]() ![]() Client: Msp Philly I Lp | Permit type: Plumbing permit | Permit status: Completed | Completion date: November 2, 2016 | Permit id: 725911 | |||||
SCORE 100 Interior plumbing construction to a point 5-0" outside only for a new attached (4)story structure with a roof deck - for use as vacant commercial space on the 1st floor (separate certificate of occupancy reqd) and (12)dwelling units on the 1st through 4th floors and a roof deck for use by the residential units - separate permit(s) required for exterior, 5"sewer 1-1 2"water connections to the city mains and the installation of the 1-1 2" backflow prevention containment assembly at the water meter - yoke vents must comply with section p-1107. 1. 1, branch vents at the lowest level must comply with section p-1110. 3 and vent terminals at the roof deck must comply with section p-1103. 4. 1 of the philadelphia plumbing code 2004 - all interior below ground piping must be bell & spigot cast iron a-74 standard with lead and oakum joints ![]() ![]() Client: Msp Philly I Lp | Permit type: Plumbing permit | Permit status: Completed | Completion date: August 26, 2017 | Permit id: 733324 | |||||
SCORE 100 Installation of 200a temporary service for construction site... In accordance with 2008 ![]() ![]() Client: Msp Philly I Lp | Permit type: Electrical permit | Permit status: Expired | Completion date: October 14, 2016 | Permit id: 724564 | |||||
Anticipated rrfusuals for accessibility and single means of egress. We are attempting to file the appeal for the 12 17 board of building standards hearing bbs variance received ![]() Client: Msp Philly I Lp | Permit type: Administrative permit | Permit status: Completed | Completion date: March 14, 2016 | Permit id: 651934 | |||||
For the erection of an attached structure ( 522") with cellar ; stair aceess to roof deck only; bay windows from 2nd floor through forth floors for a multi-family household living ( twelve(12) dwelling units) from second floor through forth floors . Size and location as shown in the application. ![]() Client: Msp Philly I Lp | Permit type: Zoning/use permit | Permit status: Completed | Completion date: May 20, 2016 | Permit id: 632933 | |||||
SCORE 100 Install wiring for light, power, communications. Includes main 800amp electrical service and metering as per nec 2008 cc district and fire alarm for new apt as per nfpa 72 ![]() ![]() Client: Msp Philly I Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: August 23, 2017 | Permit id: 723436 | |||||
For the creation of twelve(12) bycycle spaces at basement ( should be in an accessible route) with a multi-family household living ( twelve(12) dwelling units) from second floor through forth floors as previously approved. ![]() Client: Msp Philly I Lp | Permit type: Use permit | Permit status: Completed | Completion date: May 20, 2016 | Permit id: 693738 | |||||
SCORE 100 Seal lateral (sfd) pa20141752518 self-cerifications are no longer permitted - all excavations & plumbing trenches in excess of 5 in depth must have approved shoring in place at the time of inspection ![]() ![]() Client: Msp Philly I Lp | Permit type: Plumbing permit | Permit status: Completed | Completion date: August 1, 2014 | Permit id: 546717 | |||||
To amend building permit no 683609 for the addition of 2-hr fire resistance rated shaft enclosure (u529) to serve potential future restaurant use on 1st floor. Separate permit required for use registration and certificate of occupancy of the 1st floor space. All work per phc approved plans. ![]() Client: Msp Philly I Lp | Permit type: Administrative permit | Permit status: Completed | Completion date: August 26, 2017 | Permit id: 757506 |