Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 100 Replace hot water heater and relocate plumbing fixtures. Date: January 30, 2001 Contractor: Mesa Plumbing And Mechanical Inc Client: South 1000.0 | Applicant: Mesa Plumbing & Mechanical Inc | Permit type: Mechanical, plumbing | Permit status: N&v | Current use: Office - admini | |||||
SCORE 100 2825 wilderness place radio alarm pannel Date: March 2, 2007 Contractor: Safe Systems Inc Client: South 1000.0 | Applicant: Safe Systems, Inc. | Permit type: Fire | Permit status: Cmp | Completion date: May 20, 2008 | Current use: Office - techni | |||||
SCORE 96 Installation of tanklesss water heater and associated gas piping for suite 400. 450,0 btu. Date: July 24, 2008 Contractor: Bernies Plumbing And Heating Client: South 1000.0 | Applicant: Bernies Plumbing And Heating | Permit type: Mechanical | Permit status: Cmp | Completion date: June 10, 2011 | Current use: Commercial/reta | |||||
SCORE 95 Tenant remodel - of 1,513 sf includes electrical and plumbing for bathroom only. Client: South 1000.0 | Applicant: Western Asset Construction | Permit type: Building, electrical | Permit status: Cmp | Completion date: January 6, 2010 | Current use: Wholesale, tena | |||||
SCORE 100 Scope of work letter garden sun Date: February 25, 2010 Contractor: Fire Defense Inc Client: South 1000.0 | Applicant: Fire Defense, Inc. | Permit type: Fire | Permit status: Cmp | Completion date: May 3, 2010 | Current use: Manufacturing, | |||||
SCORE 56 Installation of 5 outlets using existing circuits -- suite 1000 Date: March 17, 2010 Contractor: South 1000.0 Client: South 1000.0 | Applicant: South 1000.0 | Permit type: Electrical | Permit status: Cmp | Completion date: April 1, 2010 | Current use: Warehousing, ex | |||||
SCORE 99 Mechanical permit - for hvac. See pmt2009-05101 Date: June 22, 2010 Contractor: Bagi Mechanical Llc Client: South 1000.0 | Applicant: Bagi Mechanical, Llc | Permit type: Mechanical | Permit status: Cmp | Completion date: July 1, 2010 | Current use: Manufacturing, | |||||
SCORE 96 Electrical permit - for service change replacement to 2 amps for industrial building. Date: September 21, 2010 Contractor: Positive Energy Inc Client: South 1000.0 | Applicant: Positive Energy, Inc. | Permit type: Electrical | Permit status: Cmp | Completion date: October 5, 2010 | Current use: Manufacturing, | |||||
SCORE 90 Tenant remodel - for conversion of 1,7 sf of vacant space into commercial kitchen. Includes electrical, mechanical, and plumbing. Existing bathroom to remain. (type i hood by separate permit) Client: South 1000.0 | Applicant: Crossconcepts | Permit type: Building, electrical | Permit status: Cmp | Completion date: January 12, 2011 | Current use: Manufacturing, | |||||
SCORE 64 Mechanical permit - for type i hood for commercial kitchen. See pmt2010-05032 for tenant remodel. Date: November 18, 2010 Contractor: Air Flow Heating Company Client: South 1000.0 | Applicant: Air Flow Heating Company | Permit type: Mechanical | Permit status: Cmp | Completion date: January 12, 2011 | Current use: Manufacturing, | |||||
SCORE 95 New hood extinguishing system for papusafoots rest. Date: December 17, 2010 Contractor: Sentry Fire And Safety Client: South 1000.0 | Applicant: Sentry Fire And Safety | Permit type: Fire | Permit status: Cmp | Completion date: February 14, 2011 | Current use: Restaurant, exi | |||||
SCORE 90 Scope of work letter for suite 5 addition of 3 new heads and 1 new dry pendant Date: January 5, 2011 Contractor: Platinum Fire Protection Inc Client: South 1000.0 | Applicant: Platinum Fire Protection, Inc. | Permit type: Fire | Permit status: Cmp | Completion date: February 10, 2011 | Current use: Office - profes | |||||
SCORE 76 Installation of regulators on existing gas runs to reduce pressure -- excel will be bumping up the fed pressure to the building. Date: January 28, 2011 Contractor: Steves Plumbing Inc Client: South 1000.0 | Applicant: Steves Plumbing Inc | Permit type: Mechanical | Permit status: Cmp | Completion date: March 31, 2011 | Current use: Service industr | |||||
SCORE 100 Tenant modification to an existing tenant space -- suite 100. Revised proposal reflects removal of unpermitted mezzanine and stair. Client: South 1000.0 | Applicant: Arch 11 | Permit type: Building, electrical | Permit status: Cmp | Completion date: July 27, 2011 | Current use: Manufacturing, | |||||
SCORE 95 Demo permit - for removal of unpermitted stairs, demising walls, and railing of existing mezzanine area in industrial manufacturing space. (see pmt2011-00882 for tenant remodel) Date: June 16, 2011 Contractor: Narvaes Western Llc Client: South 1000.0 | Applicant: Narvaes Western Llc | Permit type: Demolition | Permit status: Cmp | Completion date: July 27, 2011 | Current use: Manufacturing, | |||||
SCORE 99 Mechanical permit - forre-routing of gas line to existing unit heaters to put on its own meter in commercial industrial building. Date: October 11, 2011 Contractor: Economy Plumbing Heat And Air Inc Client: South 1000.0 | Applicant: Economy Plumbing, Heat & Air, Inc | Permit type: Mechanical | Permit status: Cmp | Completion date: December 7, 2011 | Current use: Warehousing, ex | |||||
SCORE 99 Installation of new 1 amp service panel off existing service for suite 12 b. Date: October 20, 2011 Contractor: Breakers Electric Llc Client: South 1000.0 | Applicant: Breakers Electric, Llc | Permit type: Electrical | Permit status: Cmp | Completion date: November 2, 2011 | Current use: Existing | |||||
SCORE 67 Installation of dryvit color coat over primer on existing concrete walls and corugated galvanized metal siding over entry doors. Date: October 28, 2011 Contractor: Miller Construction Specialties Inc Client: South 1000.0 | Applicant: Miller Construction Specialties Inc | Permit type: Siding | Permit status: Cmp | Completion date: January 10, 2012 | Current use: Existing | |||||
SCORE 100 Suite 100, replacement, non-illuminated wall sign inchthere with careinch Date: April 26, 2012 Contractor: Colorado Signworks Inc Client: Bernard Naiman | Applicant: Colorado Signworks, Inc. | Permit type: Sign | Permit status: Cmp | Completion date: December 17, 2012 | Current use: Existing | |||||
SCORE 100 Suite 400, replacement, non-illuminated wall sign inchbundleinch Date: April 26, 2012 Contractor: Colorado Signworks Inc Client: Bernard Naiman | Applicant: Colorado Signworks, Inc. | Permit type: Sign | Permit status: Cmp | Completion date: December 17, 2012 | Current use: Existing | |||||
SCORE 100 Suite 600, replacement, non-illuminated wall sign inchpatty elliotfoots placeinch Date: April 26, 2012 Contractor: Colorado Signworks Inc Client: Bernard Naiman | Applicant: Colorado Signworks, Inc. | Permit type: Sign | Permit status: Cmp | Completion date: December 17, 2012 | Current use: Existing | |||||
SCORE 100 Suite 800, replacement, non-illuminated wall sign inchshamanefoots bake shoppeinch Date: April 26, 2012 Contractor: Colorado Signworks Inc Client: Bernard Naiman | Applicant: Colorado Signworks, Inc. | Permit type: Sign | Permit status: Cmp | Completion date: December 17, 2012 | Current use: Existing | |||||
SCORE 100 Suite 1200, replacement, non-illuminated wall sign inchcat eye americainch Date: April 26, 2012 Contractor: Colorado Signworks Inc Client: Bernard Naiman | Applicant: Colorado Signworks, Inc. | Permit type: Sign | Permit status: Cmp | Completion date: December 17, 2012 | Current use: Existing | |||||
SCORE 95 Tenant remodel - of 1,513 sf includes electrical and plumbing for bathroom only. Client: South | Permit type: Building, electrical, plumbing | Permit status: Cmp | Completion date: January 6, 2010 | Current use: Wholesale, tenant remodel | Permit id: Pmt2009-05101 | |||||
SCORE 100 Replace hot water heater and relocate plumbing fixtures. Client: South | Permit type: Mechanical, plumbing | Permit status: N&v | Current use: Office - administrative, existing | Permit id: Pmt2001-00321 | |||||
SCORE 95 Suite 100, replacement, non-illuminated wall sign inchthere with careinch Client: Bernard Naiman | Permit type: Sign | Permit status: Cmp | Completion date: December 17, 2012 | Current use: Existing | Permit id: Pmt2012-01771 | |||||
SCORE 95 Suite 400, replacement, non-illuminated wall sign inchbundleinch Client: Bernard Naiman | Permit type: Sign | Permit status: Cmp | Completion date: December 17, 2012 | Current use: Existing | Permit id: Pmt2012-01772 | |||||
SCORE 95 Suite 600, replacement, non-illuminated wall sign inchpatty elliotfoots placeinch Client: Bernard Naiman | Permit type: Sign | Permit status: Cmp | Completion date: December 17, 2012 | Current use: Existing | Permit id: Pmt2012-01773 | |||||
SCORE 95 Suite 800, replacement, non-illuminated wall sign inchshamanefoots bake shoppeinch Client: Bernard Naiman | Permit type: Sign | Permit status: Cmp | Completion date: December 17, 2012 | Current use: Existing | Permit id: Pmt2012-01774 | |||||
SCORE 95 Suite 1200, replacement, non-illuminated wall sign inchcat eye americainch Client: Bernard Naiman | Permit type: Sign | Permit status: Cmp | Completion date: December 17, 2012 | Current use: Existing | Permit id: Pmt2012-01775 | |||||
SCORE 95 Scope of work letter garden sun Client: South | Permit type: Fire | Permit status: Cmp | Completion date: May 3, 2010 | Current use: Manufacturing, existing | Permit id: Pmt2010-00634 | |||||
SCORE 95 Installation of 5 outlets using existing circuits -- suite 1000 Client: South | Permit type: Electrical | Permit status: Cmp | Completion date: April 1, 2010 | Current use: Warehousing, existing | Permit id: Pmt2010-00976 | |||||
SCORE 95 Mechanical permit - for hvac. See pmt2009-05101 Client: South | Permit type: Mechanical | Permit status: Cmp | Completion date: July 1, 2010 | Current use: Manufacturing, existing | Permit id: Pmt2010-02376 | |||||
SCORE 95 Electrical permit - for service change replacement to 2 amps for industrial building. Client: South | Permit type: Electrical | Permit status: Cmp | Completion date: October 5, 2010 | Current use: Manufacturing, existing | Permit id: Pmt2010-03901 | |||||
SCORE 90 Tenant remodel - for conversion of 1,7 sf of vacant space into commercial kitchen. Includes electrical, mechanical, and plumbing. Existing bathroom to remain. (type i hood by separate permit) Client: South | Permit type: Building, electrical, mechanical, plumbing | Permit status: Cmp | Completion date: January 12, 2011 | Current use: Manufacturing, tenant remodel | Permit id: Pmt2010-05032 | |||||
SCORE 64 Mechanical permit - for type i hood for commercial kitchen. See pmt2010-05032 for tenant remodel. Client: South | Permit type: Mechanical | Permit status: Cmp | Completion date: January 12, 2011 | Current use: Manufacturing, existing | Permit id: Pmt2010-05033 | |||||
SCORE 95 New hood extinguishing system for papusafoots rest. Client: South | Permit type: Fire | Permit status: Cmp | Completion date: February 14, 2011 | Current use: Restaurant, existing | Permit id: Pmt2010-05521 | |||||
SCORE 95 2825 wilderness place radio alarm pannel Client: South | Permit type: Fire | Permit status: Cmp | Completion date: May 20, 2008 | Current use: Office - technical, existing | Permit id: Pmt2007-00682 | |||||
SCORE 89 Scope of work letter for suite 5 addition of 3 new heads and 1 new dry pendant Client: South | Permit type: Fire | Permit status: Cmp | Completion date: February 10, 2011 | Current use: Office - professional, existing | Permit id: Pmt2011-00018 | |||||
SCORE 76 Installation of regulators on existing gas runs to reduce pressure -- excel will be bumping up the fed pressure to the building. Client: South | Permit type: Mechanical | Permit status: Cmp | Completion date: March 31, 2011 | Current use: Service industrial, existing | Permit id: Pmt2011-00436 | |||||
SCORE 95 Tenant modification to an existing tenant space -- suite 100. Revised proposal reflects removal of unpermitted mezzanine and stair. Client: South | Permit type: Building, electrical, plumbing | Permit status: Cmp | Completion date: July 27, 2011 | Current use: Manufacturing, alteration | Permit id: Pmt2011-00882 | |||||
SCORE 88 Mechanical permit - forre-routing of gas line to existing unit heaters to put on its own meter in commercial industrial building. Client: South | Permit type: Mechanical | Permit status: Cmp | Completion date: December 7, 2011 | Current use: Warehousing, existing | Permit id: Pmt2011-04362 | |||||
SCORE 95 Installation of new 1 amp service panel off existing service for suite 12 b. Client: South | Permit type: Electrical | Permit status: Cmp | Completion date: November 2, 2011 | Current use: Existing | Permit id: Pmt2011-04554 | |||||
SCORE 67 Installation of dryvit color coat over primer on existing concrete walls and corugated galvanized metal siding over entry doors. Client: South | Permit type: Siding | Permit status: Cmp | Completion date: January 10, 2012 | Current use: Existing | Permit id: Pmt2011-04727 | |||||
SCORE 96 Installation of tanklesss water heater and associated gas piping for suite 400. 450,0 btu. Client: South | Permit type: Mechanical | Permit status: Cmp | Completion date: June 10, 2011 | Current use: Commercial/retail, existing | Permit id: Pmt2008-03155 |