Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Temp banner Date: August 7, 2006 Permit status: Closed | Permit id: 06-03705 | |||||
Reface existing non-conforming free standing sign Date: October 2, 2006 Permit status: Closed | Permit id: 06-01970 | |||||
Ihop restaurant Date: January 3, 2007 Permit status: Closed | Permit id: 06-00172 | |||||
Exxon Date: December 2, 2005 Permit type: Accessory structure | Permit status: Closed | Permit id: 05-06008 | |||||
Fuel station Date: November 22, 2005 Permit status: Closed | Permit id: 05-05744 | |||||
Date: August 1, 2002 Permit status: Closed | Permit id: 02-01787 | |||||
Mechanical Date: February 17, 2000 Permit status: Closed | Permit id: 00-00741 | |||||
SCORE 95 Comment date: tue apr 00:00: edt 2002 - remodel & change of use; comment date: wed may 01 00:00: edt 2002 - p&z#02-1047; comment date: wed jul 17 00:00: edt 2002 - recd amendment to relocate counter & Client: Exxon Asheville Mall | Permit type: Com: remodel | Permit status: Closed | Current use: Commercial | Permit id: 02-01787 | Parcel: 18162 | |||||
SCORE 95 Comment date: thu feb 17 00:00: est 20 - gas furnace changeout. Call alec arthur, redacted phone number. Client: Exxon | Permit type: Com: mechanical | Permit status: Closed | Current use: Commercial | Permit id: 00-00741 | Parcel: 18162 | |||||
SCORE 100 Conforming free standing sign Date: October 2, 2006 Contractor: Hilton Displays Client: Ihop | Permit type: Stand alone sign | Permit status: Closed | Current use: Sign | Permit id: 06-01970 | Parcel: 18162 | |||||
SCORE 98 Ihop restaurant Client: Ihop Restaurant | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 06-00172 | Parcel: 18162 | |||||
SCORE 65 Ihop restaurant Client: Ihop Restaurant | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 06-00172 | Parcel: 18162 | |||||
SCORE 56 Ihop restaurant Client: Ihop Restaurant | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 06-00172 | Parcel: 18162 | |||||
SCORE 56 Ihop restaurant Client: Ihop Restaurant | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 06-00172 | Parcel: 18162 | |||||
SCORE 100 Ihop restaurant Client: Ihop Restaurant | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 06-00172 | Parcel: 18162 | |||||
SCORE 100 Temp banner Date: August 7, 2006 Contractor: Lamb Sign Company Client: Ihop | Permit type: Stand alone sign | Permit status: Closed | Current use: Sign | Permit id: 06-03705 | Parcel: 18162 | |||||
Zoning enforcement Client: I-Hop Restaurant | Permit status: In compliance | Current use: Complaint-enforcement | Permit id: 06-01784s | Parcel: 18162 | |||||
Zoning enforcement Client: Exxon Corporation | Permit status: In compliance | Current use: Complaint-enforcement | Permit id: 07-02128s | Parcel: 18162 | |||||
Zoning enforcement Client: Ihop Restaurant | Permit status: In compliance | Current use: Complaint-enforcement | Permit id: 07-02771s | Parcel: 18162 | |||||
Exxon remodel Client: Sea Bp#02-1787 | Permit type: Scv level i | Permit status: Approved | Current use: Site compliance verification | Permit id: 02-10000047pz | |||||
Ihop restaurant Client: Mdw Bp#06-172 | Permit type: Scv level i | Permit status: Approved with conditions | Current use: Site compliance verification | Permit id: 05-10000144pz | |||||
Asheville savings drive thru Client: Bp #06-4068 | Permit type: Scv level i | Permit status: Under review | Current use: Site compliance verification | Permit id: 06-10000102pz | |||||
245 tunnel rd Permit type: Research zoning letters | Permit status: Closed | Current use: Research | Permit id: 15-12360pz | Parcel: 18162 | |||||
Remodel & change of use; p&z#02-1047; recd amendment to relocate counter & handicap bathroom;cah; amended 8/1/02 to replace a condensor coil/refrigeration work.; mr. Patel called and said he is the owner of om oil llc:; faxed comments to designer. 5/21/02. Ree.; planning comments: permit is issued with the following conditons: fire - parking cannot obstruct exits. Propane tanks 125 to 5 gallons shall not be within feet of the building or feet of the property line. Contact the fire department (wayne hamilton redacted phone number)if the tank exceeds 5 gallons. The existing tank must be relocated for approval. Engineering - parking stall sizes are 9 x 18. Handicapped parking is required to be 8 x 18 with an 8 side stall for vans or a 5 side stall for regular vehicles. Regional water authority comments: the regional water authoritys policy requires that backflow prevention be provided on all commerical/institutional facilities and multi-family dwellings. As a condition of your proposed ch Permit type: Com: remodel | Permit status: Closed | Permit id: 02-01787 | Parcel: 18162 | |||||
Zoning, grading, stormwater, driveways submitted. Pmd ihop restaurant; january 10, 2006 11:05:12 am ccox submitting building plans at this time.; amendment rec. Response to review;scc; recd revised siteplans. Pmd; september 19, 2006 4:16:45 pm sbrank received application for temp utilitie and stocking and training; charged 1 fee for both, 200. Paid ck 5294.; january 3, 2007 2:37: pm sbrank new commercial, i-hop restaurant.; building plans recieved. Clc; date: 1-18-06 to: lee mehler reference: new construction of an ihop at 245 tunnel rd permit number: 06-172 please respond to all the following code requirements in writing. 1. Please provide a location of handicap seating inside of r estaurant. 2. The appendix b states that this building is a type ii-b c onstruction. There is a lot of wood walls and combustible m aterials in the construction of the building. Can you e xplain? 3 . Need to provide a site plan that shows the side walks, ac cessible parking etc.; holding for reply to building Permit type: Permits - historical | Permit status: Closed | Permit id: 06-00172 | Parcel: 18162 | |||||
Zoning enforcement Permit status: In compliance | Permit id: 07-02128s | Parcel: 18162 | |||||
Zoning enforcement Permit status: In compliance | Permit id: 07-02771s | Parcel: 18162 | |||||
Zoning enforcement Permit status: In compliance | Permit id: 06-01784s | Parcel: 18162 | |||||
Zoning enforcement Date: February 9, 2007 Client: I-Hop Restaurant | Permit status: In compliance | Current use: Complaint-enforcement | Permit id: 06-01784s | Parcel: 18162 | |||||
Exxon remodel Date: May 1, 2002 Client: Sea Bp#02-1787 | Permit type: Scv level i | Permit status: Approved | Current use: Site compliance verification | Permit id: 02-10000047pz | |||||
Ihop restaurant Date: December 27, 2005 Client: Mdw Bp#06-172 | Permit type: Scv level i | Permit status: Approved with conditions | Current use: Site compliance verification | Permit id: 05-10000144pz | |||||
Asheville savings drive thru Date: August 28, 2006 Client: Bp #06-4068 | Permit type: Scv level i | Permit status: Under review | Current use: Site compliance verification | Permit id: 06-10000102pz | |||||
245 tunnel rd Date: September 22, 2015 Permit type: Research zoning letters | Permit status: Closed | Current use: Research | Permit id: 15-12360pz | Parcel: 18162 | |||||
Ihop restaurant Date: January 3, 2007 Value: $750,000 Permit type: Historical | Permit status: Closed | Permit id: 06-00172 | |||||
Fuel station Date: November 22, 2005 Value: $45,000 Permit type: Commercial | Permit status: Closed | Permit id: 05-05744 | |||||
Commercial Date: August 1, 2002 Value: $38,000 Permit status: Closed | Permit id: 02-01787 | |||||
Commercial Date: February 17, 2000 Value: $2,124 Permit status: Closed | Permit id: 00-00741 | |||||
Remodel & change of use; p&z#02-1047; recd amendment to relocate counter & handicap bathroom;cah; amended 8 1 02 to replace a condensor coil refrigeration work.; mr. Patel called and said he is the owner of om oil llc:; faxed comments to designer. 5 21 02. Ree.; planning comments: permit is issued with the following conditons: fire - parking cannot obstruct exits. Propane tanks 125 to 5 gallons shall not be within feet of the building or feet of the property line. Contact the fire department (wayne hamilton redacted phone number)if the tank exceeds 5 gallons. The existing tank must be relocated for approval. Engineering - parking stall sizes are 9 x 18. Handicapped parking is required to be 8 x 18 with an 8 side stall for vans or a 5 side stall for regular vehicles. Regional water authority comments: the regional water authoritys policy requires that backflow prevention be provided on all commerical institutional facilities and multi-family dwellings. As a condition of your proposed ch Date: August 1, 2002 Permit type: Com: remodel | Permit status: Closed | Permit id: 02-01787 | Parcel: 18162 | |||||
Snipe signs of advertisement of internet company near ihop Date: October 14, 2016 Client: Snipe Signs | Permit type: Zoe: sign violation | Permit status: Closed | Current use: Complaint-enforcement | Permit id: 16-10458s | Parcel: 18162 | |||||
SCORE 99 Removal, cleaning, and cutting for scrap metal of following underground storage tanks.; fire prevention comments see the review comments sheet for additional information and requirements. Call lewis garrison for fire inspection at redacted phone number: Date: December 2, 2005 Contractor: Griffin Wrecking Company D.H Client: Exxon | Permit type: Com: accessory structure | Permit status: Closed | Current use: Commercial | Permit id: 05-06008 | Parcel: 18162 | |||||
SCORE 95 Gas furnace changeout. Call alec arthur, redacted phone number. Client: Exxon | Permit type: Com: mechanical | Permit status: Closed | Current use: Commercial | Permit id: 00-00741 | Parcel: 18162 | |||||
SCORE 98 Comment date: tue apr 00:00: edt 2002 - remodel & change of use; comment date: wed may 01 00:00: edt 2002 - p&z#02-1047; comment date: wed jul 17 00:00: edt 2002 - recd amendment to relocate counter & Client: Exxon Asheville Mall | Permit type: Com: remodel | Permit status: Closed | Current use: Commercial | Permit id: 02-01787 | Parcel: 18162 | |||||
SCORE 95 Remodel & change of use; comment date: wed may 01 00:00: edt 2002 - p&z#02-1047; comment date: wed jul 17 00:00: edt 2002 - recd amendment to relocate counter & Client: Exxon Asheville Mall | Permit type: Com: remodel | Permit status: Closed | Current use: Commercial | Permit id: 02-01787 | Parcel: 18162 | |||||
SCORE 99 Commercial demo of fuel station;scc; building safety review comments the approved plans with the attached review comments are required to be at the job site for use by the field inspector(s) at all times. The building permit is required to be posted at the jobsite at all times. Failure to post approved permits & plans at site is a fine, fine must be paid before next inspection is requested. For building inspections call gary stamey at redacted phone number. All subcontractors need to complete trade application for project. Subcontractors need to either visit the permit office or fax copy of application to (828)redacted phone number for activation of electrical, plumbing & mechancial permits.; fire prevention call for all fire inspections at 828 redacted phone number. 1. Removal of underground storage tanks shall require on s ite inspection by the fire inspector to confirm innertness b efore off site transportation. Preferably telephone the d ay before to schedule the Permit type: Com: demo | Permit status: Closed | Current use: Commercial | Permit id: 05-05744 | Parcel: 18162 | |||||
Zoning, grading, stormwater, driveways submitted. Pmd ihop restaurant; january 10, 2006 11:05:12 am ccox submitting building plans at this time.; amendment rec. Response to review;scc; recd revised siteplans. Pmd; september 19, 2006 4:16:45 pm sbrank received application for temp utilitie and stocking and training; charged 1 fee for both, 200. Paid ck 5294.; january 3, 2007 2:37: pm sbrank new commercial, i-hop restaurant.; building plans recieved. Clc; date: 1-18-06 to: lee mehler reference: new construction of an ihop at 245 tunnel rd permit number: 06-172 please respond to all the following code requirements in writing. 1. Please provide a location of handicap seating inside of r estaurant. 2. The appendix b states that this building is a type ii-b c onstruction. There is a lot of wood walls and combustible m aterials in the construction of the building. Can you e xplain? 3 . Need to provide a site plan that shows the side walks, ac cessible parking etc.; holding for reply to building Date: January 3, 2007 Permit type: Permits - historical | Permit status: Closed | Permit id: 06-00172 | Parcel: 18162 | |||||
Zoning enforcement Date: September 14, 2007 Permit status: In compliance | Permit id: 07-02128s | Parcel: 18162 | |||||
SCORE 99 July 27, 2009 1:36:22 pm heatherr. At&t equipment #3t white pine pole; wiring bell equipment @ 3t white pine behind ihop restaurant via walk in. Call larry davis @ redacted phone number for inspection. Client: At&t Equipment #3t White | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 09-03739 | Parcel: 573518 |