Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
New construction permit ![]() Client: Marcon Holdings Ii Llc | Permit status: Active | Permit id: 620460 | |||||
Electrical permit ![]() Client: Marcon Holdings Ii Llc | Permit status: Active | Permit id: 694631 | |||||
Plumbing permit ![]() Client: Marcon Holdings Ii Llc | Permit status: Active | Permit id: 680696 | |||||
Suppression permit ![]() Client: Marcon Holdings Ii Llc | Permit status: Expired | Permit id: 631749 | |||||
Mechanical permit ![]() Client: Marcon Holdings Ii Llc | Permit status: Active | Permit id: 704380 | |||||
Zoning/use permit ![]() Client: Marcon Holdings Ii Llc | Permit status: Completed | Permit id: 606961 | |||||
Zoning use permit ![]() Client: Marcon Holdings Ii Llc | Permit status: Completed | Permit id: 606961 | |||||
SCORE 96 New construction: install 200a service, 60- outlets, 35- switches, 30- light fixtures, 7- 120v interconnected smoke detectors... In accordance with 2008 nec for a one family building ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: December 28, 2016 | Permit id: 694631 | |||||
SCORE 100 Install (1) heat system with ductwork. (sfd) ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: January 9, 2017 | Permit id: 704380 | |||||
SCORE 93 Installation of nfpa 13r sprinkler system for single family residence. 2" fire supply. Code design prof: philip sconyo, pe ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: January 9, 2017 | Permit id: 631749 | |||||
For the erection of a four story structure, one accessory off street parking space, and a roof deck, accessed by a pilot house as per approved plans. See app# 615464 for approved plans. ![]() Permit type: New construction permit | Permit status: Completed | Completion date: January 9, 2017 | Permit id: 620460 | |||||
SCORE 93 Install 5" lateral,curb trap and 1 water service pa20161342257 (sfd)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: December 7, 2016 | Permit id: 693942 | |||||
For the erection of an attached structure ( nte 38 high), bay windows at 2nd and 3rd floors; roof deck and pilot house ( for stairs and landing only) for a single family household living with one(1) car parking garage ( accessed from rear common drive aisle ) ![]() Permit type: Zoning/use permit | Permit status: Completed | Completion date: May 6, 2015 | Permit id: 606961 | |||||
SCORE 93 Interior plumbing construction throughout for a new (4)story single-family dwelling - a separate permit is required for the exterior & 5"sewer 1"water connections to the city mains - work is typical of plans filed with plumbing permit #656247 - note: the water distribution is not a combination 13d system (rfss) and the fire suppression piping is a separate 2" 13r service - the vent terminals at the deck must comply with the philadelphia plumbing code 2004 section p-1103. 4. 1 - a backflow prevention containment device is not required in this occupancy type per section p-806. 2 of the philadelphia plumbing code 2004 ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: January 9, 2017 | Permit id: 680696 |