Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Mechanical permit Date: January 29, 2015 Client: Acnma Llc | Permit status: Completed | Permit id: 581131 | |||||
Suppression permit Date: July 27, 2007 Client: Acnma Llc | Permit status: Completed | Permit id: 88306 | |||||
Plumbing permit Date: October 3, 2014 Client: Acnma Llc | Permit status: Completed | Permit id: 565829 | |||||
Suppression permit Date: January 29, 2015 Client: Acnma Llc | Permit status: Completed | Permit id: 581256 | |||||
Alteration permit Date: October 1, 2014 Client: Acnma Llc | Permit status: Completed | Permit id: 562208 | |||||
Use permit Date: August 28, 2012 Client: Acnma Llc | Permit status: Completed | Permit id: 420318 | |||||
Zoning permit Date: August 24, 2012 Client: Acnma Llc | Permit status: Completed | Permit id: 416550 | |||||
Electrical permit Date: June 25, 2012 Client: Acnma Llc | Permit status: Completed | Permit id: 411284 | |||||
Suppression permit Date: August 26, 2014 Client: Acnma Llc | Permit status: Completed | Permit id: 557957 | |||||
Electrical permit Date: February 9, 2015 Client: Acnma Llc | Permit status: Completed | Permit id: 566581 | |||||
Administrative permit Date: December 19, 2014 Client: Acnma Llc | Permit status: Completed | Permit id: 570679 | |||||
Mechanical permit Date: March 13, 2015 Client: Acnma Llc | Permit status: Completed | Permit id: 578544 | |||||
Electrical permit Date: April 9, 2015 Client: Acnma Llc | Permit status: Completed | Permit id: 590239 | |||||
Alteration permit Date: October 1, 2014 Client: Acnma Llc | Permit status: Completed | Permit id: 562208 | |||||
Use permit Date: August 28, 2012 Client: Acnma Llc | Permit status: Completed | Permit id: 420318 | |||||
Suppression permit Date: July 27, 2007 Client: Acnma Llc | Permit status: Completed | Permit id: 88306 | |||||
Suppression permit Date: January 29, 2015 Client: Acnma Llc | Permit status: Completed | Permit id: 581256 | |||||
Plumbing permit Date: November 13, 2014 Client: Acnma Llc | Permit status: Completed | Permit id: 571152 | |||||
Zoning permit Date: August 24, 2012 Client: Acnma Llc | Permit status: Completed | Permit id: 416550 | |||||
Electrical permit Date: June 25, 2012 Client: Acnma Llc | Permit status: Completed | Permit id: 411284 | |||||
Administrative permit Date: December 19, 2014 Client: Acnma Llc | Permit status: Completed | Permit id: 570679 | |||||
Suppression permit Date: August 26, 2014 Client: Acnma Llc | Permit status: Completed | Permit id: 557957 | |||||
SCORE 96 Installation of one (1) 13-6" commercial kitchen exhaust hood, three (3) rooftop exhaust fans, one (1)make up air fan with all associated supply exhaust duct work for kitchen. All work shall be done per approved plans and manufacturers specifications. Please reference ap#581256 for fire supression work. Date: January 29, 2015 Contractor: Dales Fire Extinguisher Client: Acnma Llc | Permit type: Mechanical permit | Permit status: Completed | Completion date: April 28, 2015 | Permit id: 581131 | |||||
SCORE 93 Point of sales w basic tele serv, addition of 1-200amp panel for kitchen equipment along w kitchen on 1st & bsmt levels, all new lights & recepts at basement & 1st floor only as per nec 2008 (cc district) Date: April 9, 2015 Contractor: Shelby Mechanical Inc Client: Acnma Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: May 4, 2015 | Permit id: 590239 | |||||
SCORE 96 For the installation of (1) ul 3 listed wet chemical extinguishing system with fourteen (14) flow points in accordance with nfpa 17a. Fire supression system to serve one commercial kitchen exhaust hood system (13-6") in an existing structure. Please see ap#581131 for approved kitchen hood ventilation system. Date: January 29, 2015 Contractor: Dales Fire Extinguisher Client: Acnma Llc | Permit type: Suppression permit | Permit status: Completed | Completion date: April 28, 2015 | Permit id: 581256 | |||||
SCORE 100 Install kitchen fire suppression system Date: July 27, 2007 Contractor: Atlantic Fire Equipment Co Inc Client: Acnma Llc | Permit type: Suppression permit | Permit status: Completed | Completion date: November 12, 2010 | Permit id: 88306 | |||||
SCORE 100 Install temp electric serv to feed bldg during renovation the exist serv is located in footprint of new bldg and must be removed prior to start of construction 13. 2 kv feeder from peco, peco transformer and 4 serv into bldg per 2008 nec Date: June 25, 2012 Contractor: H B Frazer Co Penna Client: Acnma Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: December 4, 2015 | Permit id: 411284 | |||||
For use as a private club rest Date: August 28, 2012 Client: Acnma Llc | Permit type: Use permit | Permit status: Completed | Completion date: August 28, 2012 | Permit id: 420318 | |||||
Relocation of lot lines to create 2 lots from 2 lots for use as a private club rest Date: August 24, 2012 Client: Acnma Llc | Permit type: Zoning permit | Permit status: Completed | Completion date: May 5, 2017 | Permit id: 416550 | |||||
SCORE 93 Relocate 155 sprinkler heads for new renovations Date: August 26, 2014 Contractor: Mk Fire Protection And Supply Client: Acnma Llc | Permit type: Suppression permit | Permit status: Completed | Completion date: September 14, 2015 | Permit id: 557957 | |||||
For level ii alterations to assembly space, alterations to include new interior finishes, provide furnishing and replace existing plumbing fixtures. No change in height or area of existing structure. No structural work associated with this application. Separate permits required for mechanical, electrical, and plumbing work. Date: October 1, 2014 Client: Acnma Llc | Permit type: Alteration permit | Permit status: Completed | Completion date: April 28, 2015 | Permit id: 562208 | |||||
SCORE 93 Relocate 2-hand sinks & 2-kitchen sinks in existing kitchen (bar restaurant) Date: October 3, 2014 Contractor: M E B Plumbing Client: Acnma Llc | Permit type: Plumbing permit | Permit status: Completed | Completion date: November 25, 2014 | Permit id: 565829 | |||||
SCORE 89 Install new customer provided light throughout & supply & install new receptacles & power for new customer appliance as per nec 2008 cc dist Date: February 9, 2015 Contractor: Rj Bear Electric Inc Client: Acnma Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: February 13, 2015 | Permit id: 566581 | |||||
For the amendment of permit #562208 to provide new interior finishes and changes to floor layout on the basement and first floor level as shown per plans. Original application approved for level ii alterations to assembly space, alterations to include new interior finishes, provide furnishing and replace existing plumbing fixtures. No change in height or area of existing structure. No structural work associated with this application. Separate permits required for mechanical, electrical, and plumbing work. Date: December 19, 2014 Client: Acnma Llc | Permit type: Administrative permit | Permit status: Completed | Completion date: April 28, 2015 | Permit id: 570679 | |||||
SCORE 93 Sanitary vent piping for (20)fixtures + (5)future fixture outlets - the installation will comply with the philadelphia plumbing code 2004 - note: approval is for sanitary venting only - revised plans will be submitted at a later date to include the water supply piping Date: November 13, 2014 Contractor: M E B Plumbing Client: Acnma Llc | Permit type: Plumbing permit | Permit status: Completed | Completion date: April 28, 2015 | Permit id: 571152 | |||||
SCORE 93 Remove one (1) rooftop unit, install three (3) rooftop units along with associated hvac throught space and install one (1) heatpump as per plans. Date: March 13, 2015 Contractor: Air Tech Heating And Cooling Client: Acnma Llc | Permit type: Mechanical permit | Permit status: Completed | Completion date: September 23, 2015 | Permit id: 578544 |