Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Electrical permit Date: August 31, 2012 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Expired | Permit id: 418656 | |||||
Alteration permit Date: August 11, 2015 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Active | Permit id: 619972 | |||||
Use permit Date: June 25, 2013 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Completed | Permit id: 479749 | |||||
Suppression permit Date: July 22, 2016 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Active | Permit id: 693002 | |||||
Electrical permit Date: August 19, 2015 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Expired | Permit id: 623834 | |||||
Demolition permit Date: July 13, 2012 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Completed | Permit id: 416217 | |||||
Plumbing permit Date: October 3, 2012 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Completed | Permit id: 430776 | |||||
Demolition permit Date: July 13, 2012 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Completed | Permit id: 416217 | |||||
Alteration permit Date: August 11, 2015 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Active | Permit id: 619972 | |||||
Plumbing permit Date: October 3, 2012 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Completed | Permit id: 430776 | |||||
Use permit Date: June 25, 2013 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Completed | Permit id: 479749 | |||||
Electrical permit Date: July 13, 2012 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Expired | Permit id: 416195 | |||||
Suppression permit Date: July 22, 2016 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Active | Permit id: 693002 | |||||
Electrical permit Date: August 19, 2015 Client: Chandar Ramdeo Roopnarine Krisendat | Permit status: Expired | Permit id: 623834 | |||||
SCORE 93 For the installation of a 13r fire supression system for a three family dwelling serviced by a 1 inch fire service line with a back flow preventer assembly. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Fire suppression system to be installed in accordance with nfpa 13r. Date: July 22, 2016 Contractor: Harring Fire Protection Llc Client: Chandar Ramdeo Roopnarine Krisendat | Permit type: Suppression permit | Permit status: Expired | Completion date: March 15, 2017 | Permit id: 693002 | |||||
SCORE 100 Install 200amp service with meter sockets & main dist panel & sub panels,& install branch circuits throughout as per nec 2008 & install fire alarm system throughout as per nfpa 72 north district Date: August 19, 2015 Contractor: Gerald Kaewell Client: Chandar Ramdeo Roopnarine Krisendat | Permit type: Electrical permit | Permit status: Expired | Completion date: August 29, 2015 | Permit id: 623834 | |||||
Use as 3 family dwelling Date: June 25, 2013 Client: Chandar Ramdeo Roopnarine Krisendat | Permit type: Use permit | Permit status: Completed | Completion date: June 25, 2013 | Permit id: 479749 | |||||
SCORE 100 Interior alterations (plumbing) - rerough the house drain, soil stack, fixture wastes and water supply piping - set fixtures (3)water closets, (3)bathtubs, (3)kitchen sinks, (3)lavatories and (3)domestic hot water heaters Date: October 3, 2012 Contractor: Norman Cole Sr, Client: Chandar Ramdeo Roopnarine Krisendat | Permit type: Plumbing permit | Permit status: Completed | Completion date: March 13, 2015 | Permit id: 430776 | |||||
SCORE 100 Interior alterations including new interior wall partitions, fire-rated shaft enclosures, and interior wall ceiling floor finishing.. Replaceing all sheetrock walls. (iebc 2009, compliance path: change in occupancy classification, higher hazard category) separate permits to be required for electrical, mechanical, plumbing, and fire suppression system installations. Date: August 11, 2015 Contractor: Superior Build Maintenance Client: Chandar Ramdeo Roopnarine Krisendat | Permit type: Alteration permit | Permit status: Expired | Completion date: March 15, 2017 | Permit id: 619972 | |||||
SCORE 98 2 amp service & equipment 4 meters with complete rewiring throughout per 2008 nec. Install new fa system as per nfpa-72(3fd)(north dist) Date: August 31, 2012 Contractor: David Bell Client: Chandar Ramdeo Roopnarine Krisendat | Permit type: Electrical permit | Permit status: Expired | Completion date: August 31, 2012 | Permit id: 418656 | |||||
SCORE 100 25 square feet, interior demolition of non load bearing walls and ceilings only. No other work allowed under this permit. Separate permits required for interior renovation. Date: July 13, 2012 Contractor: David Bell General Contrac Client: Chandar Ramdeo Roopnarine Krisendat | Permit type: Demolition permit | Permit status: Completed | Completion date: May 12, 2014 | Permit id: 416217 | |||||
SCORE 98 2 amp service & equipment 4 meters per 2008 nec Date: July 13, 2012 Contractor: David Bell Client: Chandar Ramdeo Roopnarine Krisendat | Permit type: Electrical permit | Permit status: Expired | Completion date: July 13, 2012 | Permit id: 416195 |