Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 100 Add 4 metal stud wall to 3804 and 3814 -4814 units floors 38 thru 48 21 units total Current use: Tourist hotel/m | Permit id: #200512090001 | |||||
SCORE 100 Replace existing halon sphere cylinder w new fm2 cylinder in computer room. Replace existing halon pipe w new piping for fm200. Final and test. Current use: Tourist hotel/m | Permit id: #200610124834 | |||||
SCORE 99 Fire alarm retrofit upgrade headend replace devices as needed replace devices on all floors repalcing headend on 1 f. Date: October 31, 2006 Contractor: Rose Statdner Current use: Tourist hotel/m | Permit id: #200610316471 | |||||
SCORE 56 Replace millwork panels and stone top. Cosmetic work to include re-facing cabinet doors with new hardware as per section 1134b. 2. 1 exception #4. Current use: Tourist hotel/m | Permit id: #200804180032 | |||||
Remove & replace canopy at front of building @ sansome st. Date: October 31, 2011 Current use: Food/beverage h | Permit id: #201110317941 | |||||
SCORE 100 Canopy installation; replace (e) canopy @ entry with (n) design. Current use: Tourist hotel/m | Permit id: #201109164791 | |||||
SCORE 100 Renovation of lobby front desk & grand area-expand restaurant & bar pantry of main lobby remove (e) bar clubroom & gift shop-2nd. Level-remove (e) restaurant & convert to meeting space. Current use: Food/beverage h | Permit id: #201111078433 | |||||
SCORE 100 Guestroom remodeling levels 38-48; mostly cosmetic. Extent of construction work is limited to relocation of some minor non-bearing walls upgrade 5% of total guestrooms to accessible units. Deletion relocation of electrical outlets. Current use: Tourist hotel/m | Permit id: #201111098562 | |||||
SCORE 100 Storefront only replacement doors & windows. In kind ref per 201111078433 for da checklist Current use: Tourist hotel/m | Permit id: #201111108688 | |||||
SCORE 100 Model room review; modify 2-guestrm. Unit 3803 & 3804 for ownership to evaluate 2-separate schemes. Mostly cosmetic construction work is limited to deletion & relocation of 2-partial non-bearing walls & deletion relocation of elect. Outlets. Current use: Tourist hotel/m | Permit id: #201107250956 | |||||
Canopy installation; replace (e) canopy @ entry with (n) design. Date: September 16, 2011 Current use: Tourist hotel/m | Permit id: #201109164791 | |||||
SCORE 100 1st floor - fire sprinkler only - relocate 38 heads add 9 heads delete 13 heads. For the mandarin oriental. Total 47 heads. Current use: Food/beverage h | Permit id: #201201112032 | |||||
SCORE 100 Add 1 new speaker strobe 1 new duct detector. 1 control relay 2 replacement speakers to speaker strobes 6 relocates speaker strobes Current use: Food/beverage h | Permit id: #201203125836 | |||||
SCORE 100 Relocate fitness & hotel offices from level 4 to level 3. Add spa area on level 3 - elevator lobbies women restroom & common hallway. Note: building fully sprinklered. M. E. P. Under separate permit. Current use: Tourist hotel/m | Permit id: #201203287008 | |||||
SCORE 100 Suite #4612 & 4702-add 2 strobes in ada rooms #4612 & 4702-add booster panel in 47th floor housekeeping closet & smoke detector above it Current use: Tourist hotel/m | Permit id: #201204047492 | |||||
SCORE 100 Perform all mechanical electrical & plumbing work associated with relocation of fitness & hotel offices form 4th to 3rd floor. Ref pa #2012. 03. 28. 7008. Current use: Tourist hotel/m | Permit id: #201204118088 | |||||
SCORE 100 Add fcps panels to florrs 38 39 41. Add strobes to ada rooms 3801 3809 3818 3908 3916 3918 4001 4005 4006 4105 4106 4207 4304 4316 4416 4517 2nd floor add 3 speakers 3 strobes sd-44 & increase strobe candela to 1 on speaker strobe add smoke detector above fcps on 44. Current use: Tourist hotel/m | Permit id: #201204118118 | |||||
SCORE 100 38 f 39 f 40 f 43 f -guestroom remodeling. Revision to appl#201111098562. Current use: Tourist hotel/m | Permit id: #201204178452 | |||||
SCORE 100 4th. Flr.: replace (e) chiller like for like change-out. Current use: Office | Permit id: #201205029670 | |||||
SCORE 100 3rd floor-fire sprinkler only-relocate 1 heads add 14 heads & remove 21 heads. 134 sprinklers Current use: Tourist hotel/m | Permit id: #201205180728 | |||||
SCORE 100 38th floor fire sprinkler only - suite - oriental : 11 heads all relo 4 deletes. Suite taipan: 14 heads 8 relocate 6 add 4 delete total 25 heads. Current use: Tourist hotel/m | Permit id: #201207054098 | |||||
Permit to operate boiler Date: March 16, 2009 Permit status: Issued | Expiration date: March 16, 2009 | Permit id: 44707 | |||||
Add 1 new speaker strobe 1 new duct detector. 1 control relay 2 replacement speakers to speaker/strobes 6 relocates speaker strobes Value: $8,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: March 12, 2012 | Expiration date: March 7, 2013 | Current use: Food/beverage hndlng | Permit id: 201203125836 | |||||
Permit to operate boiler Date: April 28, 2014 Permit status: Issued | Expiration date: April 28, 2014 | Permit id: 73329 | |||||
38th floor fire sprinkler only - suite - oriental : 11 heads all relo 4 deletes. Suite taipan: 14 heads 8 relocate 6 add 4 delete total 25 heads. Value: $10,500 Permit type: Otc alterations permit | Permit status: Issued | Completion date: July 5, 2012 | Expiration date: June 30, 2013 | Current use: Tourist hotel/motel | Permit id: 201207054098 | |||||
Permit to operate boiler Date: May 12, 2016 Permit status: Issued | Expiration date: May 12, 2016 | Permit id: 87411 | |||||
SCORE 88 Dining area on 1st floor: matot - dumbwaiter 1 of 2 at this location. Date: March 7, 2012 Contractor: Mckinley Equipment Corp Permit type: Electrical permit | Permit status: Issued | Permit id: E201203071297 | |||||
Permit to operate boiler Date: June 28, 2001 Permit status: Issued | Expiration date: June 28, 2001 | Permit id: 15466 | |||||
Install projecting illuminated double faced sign Value: $7,000 Permit type: Sign-errect | Permit status: Filed | Completion date: November 10, 2015 | Current use: Tourist hotel/motel | Permit id: 201511102200 | |||||
Permit to operate boiler Date: December 15, 2004 Permit status: Issued | Expiration date: December 15, 2004 | Permit id: 26679 | |||||
Permit to operate boiler Date: February 24, 2011 Permit status: Issued | Expiration date: February 24, 2011 | Permit id: 55174 | |||||
Mta parking only Permit type: Otc alterations permit | Permit status: Issued | Completion date: January 10, 2012 | Permit id: M295567 | |||||
Remove extg carpet/some sheetrock from walls furnishings Value: $15,900 Permit type: Otc alterations permit | Permit status: Complete | Completion date: December 29, 1999 | Current use: Food/beverage hndlng | Permit id: 9927218 | |||||
Permit to operate boiler Date: March 5, 2012 Permit status: Issued | Expiration date: March 5, 2012 | Permit id: 60983 | |||||
Selective demolition new construction installation elevato Value: $20,000 Permit type: Additions alterations or repairs | Permit status: Complete | Completion date: May 26, 1995 | Expiration date: January 25, 1996 | Current use: Office | Permit id: 9507917 | |||||
Permit to operate boiler Date: November 20, 2002 Permit status: Issued | Expiration date: November 20, 2002 | Permit id: 19062 | |||||
Permit to operate boiler Date: May 4, 2006 Permit status: Issued | Expiration date: May 4, 2006 | Permit id: 32257 | |||||
SCORE 100 Relocate fitness & hotel offices from level 4 to level 3. Add spa area on level 3 - elevator lobbies women restroom & common hallway. Note: building fully sprinklered. M. E. P. Under separate permit. Permit type: Building permit | Expiration date: March 30, 2014 | Current use: Tourist hotel/motel | Permit id: #201203287008 | |||||
Storefront only "replacement" doors & windows. In kind ref per 201111078433 for da checklist Value: $100,000 Permit type: Otc alterations permit | Permit status: Issued | Completion date: November 10, 2011 | Expiration date: November 11, 2012 | Current use: Tourist hotel/motel | Permit id: 201111108688 | |||||
Permit to operate boiler Date: March 29, 2013 Permit status: Issued | Expiration date: March 29, 2013 | Permit id: 66814 | |||||
SCORE 100 4th. Flr.: replace (e) chiller "like for like" change-out. Permit type: Building permit | Expiration date: May 4, 2014 | Current use: Office | Permit id: #201205029670 | |||||
Install one halon fire suppression system Value: $6,300 Permit type: Additions alterations or repairs | Permit status: Complete | Completion date: January 7, 1992 | Expiration date: July 31, 1992 | Current use: Office | Permit id: 9200182 | |||||
SCORE 100 Storefront only "replacement" doors & windows. In kind ref per 201111078433 for da checklist Permit type: Building permit | Expiration date: November 17, 2012 | Current use: Tourist hotel/motel | Permit id: #201111108688 | |||||
Permit to operate boiler Date: April 30, 2010 Permit status: Issued | Expiration date: April 30, 2010 | Permit id: 49839 | |||||
Remove & replace canopy at front of building @ sansome st. Date: October 31, 2011 Permit type: Building permit | Current use: Food/beverage hndlng | Permit id: #201110317941 | |||||
Permit to operate boiler Date: September 13, 2007 Permit status: Issued | Expiration date: September 13, 2007 | Permit id: 38490 | |||||
1st floor - fire sprinkler only - relocate 38 heads add 9 heads delete 13 heads. For the mandarin oriental. Total 47 heads. Value: $23,500 Permit type: Otc alterations permit | Permit status: Complete | Completion date: January 11, 2012 | Expiration date: January 5, 2013 | Current use: Food/beverage hndlng | Permit id: 201201112032 | |||||
Street space Permit type: Otc alterations permit | Permit status: Issued | Completion date: November 21, 2005 | Permit id: M35435 | |||||
38/f 39/f 40/f 43/f -guestroom remodeling. Revision to appl#201111098562. Value: $200,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: April 17, 2012 | Expiration date: April 11, 2015 | Current use: Tourist hotel/motel | Permit id: 201204178452 | |||||
Suite #4612 & 4702-add 2 strobes in ada rooms #4612 & 4702-add booster panel in 47th floor housekeeping closet & smoke detector above it Value: $5,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: April 4, 2012 | Expiration date: March 30, 2013 | Current use: Tourist hotel/motel | Permit id: 201204047492 | |||||
Cti-3 floor 4th sp Value: $1,000 Permit type: Additions alterations or repairs | Permit status: Complete | Completion date: May 24, 1996 | Expiration date: October 3, 1996 | Current use: Office | Permit id: 9609135 | |||||
Cut out restaurant dining rms/reconfigurate etc. Value: $440,000 Permit type: Additions alterations or repairs | Permit status: Complete | Completion date: December 10, 1999 | Expiration date: February 23, 2002 | Current use: Food/beverage hndlng | Permit id: 9926001 | |||||
Canopy installation; replace (e) canopy @ entry with (n) design. Value: $20,000 Permit type: Otc alterations permit | Permit status: Issued | Completion date: September 16, 2011 | Expiration date: November 17, 2012 | Current use: Tourist hotel/motel | Permit id: 201109164791 | |||||
Street space Permit type: Otc alterations permit | Permit status: Issued | Completion date: March 3, 2006 | Permit id: M36596 | |||||
Renovation of guest rooms to fully comply with access req. Value: $15,000 Permit type: Additions alterations or repairs | Permit status: Complete | Completion date: February 16, 1995 | Expiration date: September 22, 1995 | Current use: Tourist hotel/motel | Permit id: 9502269 | |||||
Replace existing halon sphere cylinder w/ new fm2 cylinder in computer room. Replace existing halon pipe w/ new piping for fm200. Final and test. Value: $9,660 Permit type: Additions alterations or repairs | Permit status: Issued | Completion date: October 12, 2006 | Expiration date: May 20, 2007 | Current use: Tourist hotel/motel | Permit id: 200610124834 | |||||
Remove & replace canopy at front of building @ sansome st. Value: $100,000 Permit type: Otc alterations permit | Permit status: Filed | Completion date: October 31, 2011 | Current use: Food/beverage hndlng | Permit id: 201110317941 | |||||
Renovation of lobby front desk & grand area-expand restaurant & bar pantry of main lobby remove (e) bar clubroom & gift shop-2nd. Level-remove (e) restaurant & convert to meeting space. Value: $3,037,673 Permit type: Otc alterations permit | Permit status: Issued | Completion date: November 7, 2011 | Expiration date: December 2, 2015 | Current use: Food/beverage hndlng | Permit id: 201111078433 | |||||
Add and relocate fire sprinklers Value: $4,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: January 21, 2000 | Expiration date: May 21, 2000 | Current use: Food/beverage hndlng | Permit id: 20000121685 | |||||
Relocate fitness & hotel offices from level 4 to level 3. Add spa area on level 3 - elevator lobbies women restroom & common hallway. Note: building fully sprinklered. M. E. P. Under separate permit. Value: $1,000,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: March 28, 2012 | Expiration date: March 15, 2015 | Current use: Tourist hotel/motel | Permit id: 201203287008 | |||||
Model room review; modify 2-guestrm. Unit 3803 & 3804 for ownership to evaluate 2-separate schemes. Mostly cosmetic construction work is limited to deletion & relocation of 2-partial non-bearing walls & deletion relocation of elect. Outlets. Value: $25,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: July 25, 2011 | Expiration date: July 20, 2012 | Current use: Tourist hotel/motel | Permit id: 201107250956 | |||||
4th. Flr.: replace (e) chiller "like for like" change-out. Value: $350,000 Permit type: Otc alterations permit | Permit status: Issued | Completion date: May 2, 2012 | Expiration date: April 19, 2015 | Current use: Office | Permit id: 201205029670 | |||||
New wall partition & door Value: $4,200 Permit type: Otc alterations permit | Permit status: Expired | Completion date: December 16, 1994 | Expiration date: April 16, 1995 | Current use: Food/beverage hndlng | Permit id: 9420725 | |||||
Perform all mechanical electrical & plumbing work associated with relocation of fitness & hotel offices form 4th to 3rd floor. Ref pa #2012. 03. 28. 7008. Value: $300,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: April 11, 2012 | Expiration date: April 30, 2015 | Current use: Tourist hotel/motel | Permit id: 201204118088 | |||||
Replace millwork panels and stone top. Cosmetic work to include re-facing cabinet doors with new hardware as per section 1134b. 2. 1 exception #4. Value: $50,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: April 18, 2008 | Expiration date: April 18, 2009 | Current use: Tourist hotel/motel | Permit id: 200804180032 | |||||
Cti-2 4th floor Value: $20,000 Permit type: Additions alterations or repairs | Permit status: Complete | Completion date: May 17, 1996 | Expiration date: November 24, 1996 | Current use: Office | Permit id: 9608626 | |||||
Interior renovation at restaurant and bar on level 1. N/a ordinance #155-13- new occupoant load- sffd permit required for assembly Value: $850,000 Permit type: Otc alterations permit | Permit status: Filed | Completion date: February 18, 2016 | Current use: Food/beverage hndlng | Permit id: 201602189863 | |||||
3rd floor-fire sprinkler only-relocate 1 heads add 14 heads & remove 21 heads. 134 sprinklers Value: $68,876 Permit type: Otc alterations permit | Permit status: Issued | Completion date: May 18, 2012 | Expiration date: May 13, 2013 | Current use: Tourist hotel/motel | Permit id: 201205180728 | |||||
Add fcps panels to florrs 38 39 41. Add strobes to ada rooms 3801 3809 3818 3908 3916 3918 4001 4005 4006 4105 4106 4207 4304 4316 4416 4517 2nd floor add 3 speakers 3 strobes sd-44 & increase strobe candela to 1 on speaker/strobe add smoke detector above fcps on 44. Value: $20,000 Permit type: Otc alterations permit | Permit status: Issued | Completion date: April 11, 2012 | Expiration date: April 6, 2013 | Current use: Tourist hotel/motel | Permit id: 201204118118 | |||||
Add 4 " metal stud wall to 3804 and 3814 -4814 units floors 38 thru 48 21 units total Value: $34,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: December 9, 2005 | Expiration date: December 9, 2006 | Current use: Tourist hotel/motel | Permit id: 200512090001 | |||||
Remodel work under app #9926001 Value: $12,000 Permit type: Additions alterations or repairs | Permit status: Expired | Completion date: February 24, 2000 | Expiration date: September 13, 2000 | Current use: Food/beverage hndlng | Permit id: 200002242744 | |||||
Street space permit Permit type: Otc alterations permit | Permit status: Issued | Completion date: November 21, 2011 | Permit id: M289907 | |||||
Guestroom remodeling levels 38-48; mostly cosmetic. Extent of construction work is limited to relocation of some minor non-bearing walls upgrade 5% of total guestrooms to accessible units. Deletion/relocation of electrical outlets. Value: $1,900,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: November 9, 2011 | Expiration date: November 1, 2014 | Current use: Tourist hotel/motel | Permit id: 201111098562 | |||||
Fire sprinkler elevator modernization remove heads in top of elevator hoistway and in machine room on roof (ab2. 01 add "d") no plan required. N/a ordinance #155-13 Value: $2,500 Permit type: Otc alterations permit | Permit status: Issued | Completion date: August 24, 2015 | Expiration date: December 24, 2015 | Current use: Tourist hotel/motel | Permit id: 201508245081 | |||||
Remove extg carpet some sheetrock from walls furnishings Date: December 29, 1999 Value: $15,900 Permit type: Otc alterations permit | Permit status: Complete | Expiration date: December 29, 1999 | Current use: Food/beverage hndlng | Permit id: 9927218 | |||||
Permit to operate boiler Date: March 25, 2015 Permit status: Issued | Expiration date: March 25, 2015 | Permit id: 79084 | |||||
Add 1 new speaker strobe 1 new duct detector. 1 control relay 2 replacement speakers to speaker strobes 6 relocates speaker strobes Date: March 12, 2012 Value: $8,000 Permit type: Otc alterations permit | Permit status: Complete | Expiration date: March 12, 2012 | Current use: Food/beverage hndlng | Permit id: 201203125836 | |||||
Permit to operate boiler Date: May 20, 2008 Permit status: Issued | Expiration date: May 20, 2008 | Permit id: 40621 | |||||
Permit to operate boiler Date: November 18, 2003 Permit status: Issued | Expiration date: November 18, 2003 | Permit id: 22793 | |||||
38 f 39 f 40 f 43 f -guestroom remodeling. Revision to appl#201111098562. Date: April 17, 2012 Value: $200,000 Permit type: Otc alterations permit | Permit status: Complete | Expiration date: April 17, 2012 | Current use: Tourist hotel/motel | Permit id: 201204178452 | |||||
Cut out restaurant dining rms reconfigurate etc. Date: December 10, 1999 Value: $440,000 Permit type: Additions alterations or repairs | Permit status: Complete | Expiration date: December 10, 1999 | Current use: Food/beverage hndlng | Permit id: 9926001 | |||||
Replace existing halon sphere cylinder w new fm2 cylinder in computer room. Replace existing halon pipe w new piping for fm200. Final and test. Date: October 12, 2006 Value: $9,660 Permit type: Additions alterations or repairs | Permit status: Issued | Expiration date: October 12, 2006 | Current use: Tourist hotel/motel | Permit id: 200610124834 | |||||
Interior renovation at restaurant and bar on level1 includes mep -sprinklers fire alarm sep. Permitm c new occupoant load-n c maher ordinance no133. 13 Date: February 18, 2016 Value: $850,000 Permit type: Otc alterations permit | Permit status: Issued | Expiration date: February 18, 2016 | Current use: Food/beverage hndlng | Permit id: 201602189863 | |||||
Add fcps panels to florrs 38 39 41. Add strobes to ada rooms 3801 3809 3818 3908 3916 3918 4001 4005 4006 4105 4106 4207 4304 4316 4416 4517 2nd floor add 3 speakers 3 strobes sd-44 & increase strobe candela to 1 on speaker strobe add smoke detector above fcps on 44. Date: April 11, 2012 Value: $20,000 Permit type: Otc alterations permit | Permit status: Issued | Expiration date: April 11, 2012 | Current use: Tourist hotel/motel | Permit id: 201204118118 | |||||
Guestroom remodeling levels 38-48; mostly cosmetic. Extent of construction work is limited to relocation of some minor non-bearing walls upgrade 5% of total guestrooms to accessible units. Deletion relocation of electrical outlets. Date: November 9, 2011 Value: $1,900,000 Permit type: Otc alterations permit | Permit status: Complete | Expiration date: November 9, 2011 | Current use: Tourist hotel/motel | Permit id: 201111098562 | |||||
Fire sprinkler elevator modernization remove heads in top of elevator hoistway and in machine room on roof (ab2. 01 add "d") no plan required. N a ordinance #155-13 Date: August 24, 2015 Value: $2,500 Permit type: Otc alterations permit | Permit status: Issued | Expiration date: August 24, 2015 | Current use: Tourist hotel/motel | Permit id: 201508245081 | |||||
Metro job #38228m - 38th floor relocate existing electrical outlets to new wall locations in rooms 3803 and 3804. Replace existing switches and outlets to remain. (1) lighted mirror Permit status: Complete | Permit id: Ew20110810261 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207567 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207580 | |||||
Refurbish suites mandarin hotel. Permit status: Complete | Permit id: E200402189230 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207570 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207576 | |||||
(6) lights; (4) switches; (4) receptacles; (2) circuits; #12 feeders; ground - lobby area; mandarin hotel; cei# 08-4121 [scope of work does not include residential electric space heater installation.] Permit status: Expired | Permit id: Ew20080411762 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207579 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207573 | |||||
Metro job #38293m - mandarin hotel lobby - (170) lights (20) switches (30) receptacles Permit status: Complete | Permit id: Ew20120127122 | |||||
3 lights; remove existing and install three new chandeliers; lobby entrance; cei job #07-4121 [scope of work does not include residential electric space heater installation.] Permit status: Complete | Permit id: Ew20070814461 | |||||
Elevator project Permit status: Filed | Permit id: Ew20141030821 | |||||
Install 44 data cables on the first floor lobby. Permit status: Complete | Permit id: E20120217869 | |||||
Dimming system [scope of work does not include residential electric space heater installation.] Permit status: Complete | Permit id: Ew20080717784 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207581 | |||||
Electrical remodel Permit status: Expired | Permit id: Ew20051207571 | |||||
2nd floor ballrooms and floors of suites; mandarin hotel; cei job #11-4345 pc Permit status: Complete | Permit id: Ew20120217261 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207575 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207578 | |||||
Dining area on 1st floor: matot - dumbwaiter 1 of 2 at this location. Permit status: Complete | Permit id: E201203071297 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207574 | |||||
Workcategory:6pa;installgoslyngrds Date: April 28, 2014 Permit status: Complete | Expiration date: April 28, 2014 | Permit id: Pw20140428717 | |||||
Workcategory:5p;firstfloor addingmensandwomensrestroom. Date: May 7, 2012 Permit status: Complete | Expiration date: May 7, 2012 | Permit id: Pw20120507905 | |||||
Workcategory:4pb;relocate38heads add9headsanddelete13heads #1144349 Date: January 12, 2012 Permit status: Complete | Expiration date: January 12, 2012 | Permit id: Pw20120112695 | |||||
Workcategory:5p;replacementofshowerpanforroom4005. Date: May 1, 2012 Permit status: Complete | Expiration date: May 1, 2012 | Permit id: Pw20120501795 | |||||
Workcategory:4pb;firesprinkler3rdfl #1244537 Date: June 25, 2012 Permit status: Complete | Expiration date: June 25, 2012 | Permit id: Pw20120625871 | |||||
Workcategory:5p;re-routeexistingplumbinglocationforonesink. Date: July 5, 2011 Permit status: Expired | Expiration date: July 5, 2011 | Permit id: Pw20110705360 | |||||
Workcategory:2pa;showerpaninspectionon38thfloor Date: August 7, 2012 Permit status: Complete | Expiration date: August 7, 2012 | Permit id: Pw20120807725 | |||||
Workcategory:5p;spa(includestoiletrooms treatmentsinks pedicurechairswithrps)onthe3rdfloorofthemandarinhotel. Date: June 8, 2012 Permit status: Complete | Expiration date: June 8, 2012 | Permit id: Pw20120608563 | |||||
Workcategory:5p;secondfloorpublicrestroomadarenovations. Date: March 19, 2012 Permit status: Expired | Expiration date: March 19, 2012 | Permit id: Pw20120319984 | |||||
Workcategory:5p;renovationofmodelroom. Date: August 5, 2011 Permit status: Complete | Expiration date: August 5, 2011 | Permit id: Pw20110805926 | |||||
Workcategory:2pa;showerpaninspection Date: July 18, 2012 Permit status: Complete | Expiration date: July 18, 2012 | Permit id: Pw20120718287 | |||||
Workcategory:4pb;firesprinklerelevatormodernization-removesprinklersandpipefromelevatorhoistwayandmachineroomonroof Date: August 24, 2015 Permit status: Complete | Expiration date: August 24, 2015 | Permit id: Pw20150824727 | |||||
Workcategory:5p;renovationofhotelroomsconvertingtoada. Date: February 29, 2012 Permit status: Complete | Expiration date: February 29, 2012 | Permit id: Pw20120229620 | |||||
Workcategory:4pb;suiteoriental-11heads allrelo 4delete Date: July 6, 2012 Permit status: A | Expiration date: July 6, 2012 | Permit id: Pw20120706047 | |||||
Workcategory:5p;rough-infornewlobbybarandrestaurant Date: January 27, 2012 Permit status: Complete | Expiration date: January 27, 2012 | Permit id: Pw20120127980 | |||||
Electrical remodel Permit status: Expired | Permit id: Ew20051207571 | |||||
Dimming system [scope of work does not include residential electric space heater installation.] Permit status: Complete | Permit id: Ew20080717784 | |||||
Elevator project Permit status: Filed | Permit id: Ew20141030821 | |||||
Metro job #38293m - mandarin hotel lobby - (170) lights (20) switches (30) receptacles Permit status: Complete | Permit id: Ew20120127122 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207579 | |||||
(6) lights; (4) switches; (4) receptacles; (2) circuits; #12 feeders; ground - lobby area; mandarin hotel; cei# 08-4121 [scope of work does not include residential electric space heater installation.] Permit status: Expired | Permit id: Ew20080411762 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207576 | |||||
3 lights; remove existing and install three new chandeliers; lobby entrance; cei job #07-4121 [scope of work does not include residential electric space heater installation.] Permit status: Complete | Permit id: Ew20070814461 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207570 | |||||
Refurbish suites mandarin hotel. Permit status: Complete | Permit id: E200402189230 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207567 | |||||
Metro job #38228m - 38th floor relocate existing electrical outlets to new wall locations in rooms 3803 and 3804. Replace existing switches and outlets to remain. (1) lighted mirror Permit status: Complete | Permit id: Ew20110810261 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207581 | |||||
Install 44 data cables on the first floor lobby. Permit status: Complete | Permit id: E20120217869 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207580 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207573 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207575 | |||||
2nd floor ballrooms and floors of suites; mandarin hotel; cei job #11-4345 pc Permit status: Complete | Permit id: Ew20120217261 | |||||
Dining area on 1st floor: matot - dumbwaiter 1 of 2 at this location. Permit status: Complete | Permit id: E201203071297 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207578 | |||||
Electrical remodel Permit status: Complete | Permit id: Ew20051207574 | |||||
Permit to operate boiler Date: May 2, 2017 Permit status: Issued | Expiration date: May 2, 2017 | Permit id: 94360 | |||||
Add 4 " metal stud wall to 3804 and 3814 -4814 units, floors 38 thru 48, 21 units total Date: December 9, 2005 Value: $34,000 Permit type: Otc alterations permit | Completion date: May 19, 2006 | Expiration date: December 9, 2005 | Current use: Tourist hotel/motel | Permit id: 200512090001 | |||||
2nd level - provide new lighting & title -24 @ ballroom areas. Maher 155-13 na Date: April 19, 2017 Value: $30,515 Permit type: Otc alterations permit | Expiration date: April 14, 2017 | Current use: Tourist hotel/motel | Permit id: 201704144033 | |||||
Selective demolition, new construction, installation elevato Date: July 25, 1995 Value: $20,000 Permit type: Additions alterations or repairs | Completion date: January 19, 1996 | Expiration date: May 26, 1995 | Current use: Office | Permit id: 9507917 | |||||
Cut out restaurant dining rms reconfigurate etc. Date: February 23, 2000 Value: $440,000 Permit type: Additions alterations or repairs | Completion date: April 24, 2000 | Expiration date: December 10, 1999 | Current use: Food/beverage hndlng | Permit id: 9926001 | |||||
Interior renovation @ hotel lobby, stair, elevator lobby. Includes m. E. P. Fire alarm separate permit. Maher: n a Date: November 7, 2017 Value: $624,825 Permit type: Additions alterations or repairs | Expiration date: March 9, 2017 | Current use: Tourist hotel/motel | Permit id: 201703091093 | |||||
Street space permit Date: December 8, 2017 Permit type: Otc alterations permit | Expiration date: December 8, 2017 | Permit id: M864547 | |||||
Model room review; modify 2-guestrm., unit 3803 & 3804 for ownership to evaluate 2-separate schemes. Mostly cosmetic construction work is limited to deletion & relocation of 2-partial non-bearing walls & deletion relocation of elect. Outlets. Date: July 26, 2011 Value: $25,000 Permit type: Otc alterations permit | Completion date: October 17, 2011 | Expiration date: July 25, 2011 | Current use: Tourist hotel/motel | Permit id: 201107250956 | |||||
Renovation of lobby, front desk & grand area-expand restaurant & bar, pantry of main lobby, remove (e) bar, clubroom & gift shop-2nd. Level-remove (e) restaurant & convert to meeting space. Date: December 23, 2011 Value: $3,037,673 Permit type: Otc alterations permit | Expiration date: November 7, 2011 | Current use: Food/beverage hndlng | Permit id: 201111078433 | |||||
Guestroom remodeling levels 38-48; mostly cosmetic. Extent of construction work is limited to relocation of some minor non-bearing walls, upgrade 5% of total guestrooms to accessible units. Deletion relocation of electrical outlets. Date: November 17, 2011 Value: $1,900,000 Permit type: Otc alterations permit | Completion date: January 25, 2013 | Expiration date: November 9, 2011 | Current use: Tourist hotel/motel | Permit id: 201111098562 | |||||
Storefront only "replacement" doors & windows. In kind, ref per 201111078433 for da checklist Date: November 17, 2011 Value: $100,000 Permit type: Otc alterations permit | Expiration date: November 10, 2011 | Current use: Tourist hotel/motel | Permit id: 201111108688 | |||||
1st floor - fire sprinkler only - relocate 38 heads, add 9 heads, delete 13 heads. For the mandarin oriental. Total 47 heads. Date: January 11, 2012 Value: $23,500 Permit type: Otc alterations permit | Completion date: May 16, 2012 | Expiration date: January 11, 2012 | Current use: Food/beverage hndlng | Permit id: 201201112032 | |||||
Add 1 new speaker strobe 1 new duct detector. 1 control relay, 2 replacement speakers to speaker strobes, 6 relocates speaker strobes Date: March 12, 2012 Value: $8,000 Permit type: Otc alterations permit | Completion date: September 10, 2012 | Expiration date: March 12, 2012 | Current use: Food/beverage hndlng | Permit id: 201203125836 | |||||
Relocate fitness & hotel offices from level 4 to level 3. Add spa area on level 3 - elevator lobbies, women restroom & common hallway. Note: building fully sprinklered. M. E. P. Under separate permit. Date: March 30, 2012 Value: $1,000,000 Permit type: Otc alterations permit | Completion date: January 28, 2013 | Expiration date: March 28, 2012 | Current use: Tourist hotel/motel | Permit id: 201203287008 | |||||
Perform all mechanical, electrical & plumbing work associated with relocation of fitness & hotel offices form 4th to 3rd floor. Ref pa #2012. 03. 28. 7008. Date: May 15, 2012 Value: $300,000 Permit type: Otc alterations permit | Completion date: January 28, 2013 | Expiration date: April 11, 2012 | Current use: Tourist hotel/motel | Permit id: 201204118088 | |||||
Add fcps panels to florrs 38, 39, 40, 41. Add strobes to ada rooms 3801,3809, 3818, 3908, 3916, 3918, 4001,4005,4006,4105, 4106, 4207, 4304,4316,4416,4517 2nd floor add 3 speakers, 3 strobes, sd-44 & increase strobe candela to 1 on speaker strobe, add smoke detector above fcps on 44. Date: April 11, 2012 Value: $20,000 Permit type: Otc alterations permit | Expiration date: April 11, 2012 | Current use: Tourist hotel/motel | Permit id: 201204118118 | |||||
38 f, 39 f, 40 f, 43 f -guestroom remodeling. Revision to appl#201111098562. Date: April 26, 2012 Value: $200,000 Permit type: Otc alterations permit | Completion date: January 25, 2013 | Expiration date: April 17, 2012 | Current use: Tourist hotel/motel | Permit id: 201204178452 | |||||
3rd floor-fire sprinkler only-relocate 1 heads, add 14 heads & remove 21 heads. 134 sprinklers Date: May 18, 2012 Value: $68,876 Permit type: Otc alterations permit | Expiration date: May 18, 2012 | Current use: Tourist hotel/motel | Permit id: 201205180728 | |||||
38th floor fire sprinkler only - suite - oriental : 11 heads, all relo, 4 deletes. Suite taipan: 14 heads , 8 relocate, 6 add, 4 delete, total 25 heads. Date: July 5, 2012 Value: $10,500 Permit type: Otc alterations permit | Expiration date: July 5, 2012 | Current use: Tourist hotel/motel | Permit id: 201207054098 | |||||
Fire sprinkler elevator modernization, remove heads in top of elevator hoistway and in machine room on roof (ab2. 01, add "d"), no plan required. N a ordinance #155-13 Date: August 24, 2015 Value: $2,500 Permit type: Otc alterations permit | Expiration date: August 24, 2015 | Current use: Tourist hotel/motel | Permit id: 201508245081 | |||||
Interior renovation at restaurant and bar on level1, includes mep -sprinklers fire alarm sep. Permitm c new occupoant load-n c maher ordinance no133. 13 Date: December 28, 2016 Value: $850,000 Permit type: Otc alterations permit | Expiration date: February 18, 2016 | Current use: Food/beverage hndlng | Permit id: 201602189863 | |||||
Electrical remodel Date: December 7, 2005 Permit status: Complete | Completion date: April 7, 2006 | Permit id: Ew20051207578 | |||||
Dining area on 1st floor: matot - dumbwaiter 1 of 2 at this location. Date: March 7, 2012 Permit status: Complete | Completion date: May 17, 2012 | Permit id: E201203071297 | |||||
Metro job #38228m - 38th floorrelocate existing electrical outlets to new wall locations in rooms 3803 and 3804. Replace existing switches and outlets to remain.(1) lighted mirror Date: August 10, 2011 Permit status: Complete | Completion date: May 15, 2012 | Permit id: Ew20110810261 | |||||
Install 44 data cables on the first floor lobby. Date: February 17, 2012 Permit status: Complete | Completion date: February 6, 2013 | Permit id: E20120217869 | |||||
Metro job #38293m - mandarin hotel, lobby - (170) lights, (20) switches, (30) receptacles Date: January 27, 2012 Permit status: Complete | Completion date: February 6, 2013 | Permit id: Ew20120127122 | |||||
3 lights; remove existing and install three new chandeliers; lobby entrance; cei job #07-4121 [scope of work does not include residential electric space heater installation.] Date: August 14, 2007 Permit status: Complete | Completion date: August 21, 2007 | Permit id: Ew20070814461 | |||||
Metro job #64756panel boards (2)switches (3)circuits (24) Date: September 18, 2017 Permit status: Complete | Completion date: September 22, 2017 | Permit id: Ew201709188044 | |||||
Refurbish suites, mandarin hotel. Date: February 18, 2004 Permit status: Complete | Completion date: April 19, 2004 | Permit id: E200402189230 | |||||
Dimming system [scope of work does not include residential electric space heater installation.] Date: July 17, 2008 Permit status: Complete | Completion date: December 8, 2008 | Permit id: Ew20080717784 | |||||
(6) lights; (4) switches; (4) receptacles; (2) circuits; #12 feeders; ground - lobby area; mandarin hotel; cei# 08-4121 [scope of work does not include residential electric space heater installation.] Date: April 11, 2008 Permit status: Expired | Permit id: Ew20080411762 | |||||
Elevator project Date: October 30, 2014 Permit status: Complete | Completion date: September 15, 2016 | Permit id: Ew20141030821 | |||||
2nd floor ballrooms and floors of suites; mandarin hotel; cei job #11-4345 pc Date: February 17, 2012 Permit status: Complete | Completion date: February 6, 2013 | Permit id: Ew20120217261 | |||||
Work category: 6pa; install goslyn grds Date: April 28, 2014 Permit status: Complete | Completion date: June 3, 2014 | Expiration date: April 28, 2014 | Permit id: Pw20140428717 | |||||
Work category: 4pb; fire sprinkler elevator modernization - remove sprinklers and pipe from elevator hoistway and machine room on roof Date: August 24, 2015 Permit status: Complete | Completion date: November 12, 2015 | Expiration date: August 24, 2015 | Permit id: Pw20150824727 | |||||
Work category: 2pa; shower pan inspection on 38th floor Date: August 7, 2012 Permit status: Complete | Completion date: September 17, 2012 | Expiration date: August 7, 2012 | Permit id: Pw20120807725 | |||||
Work category: 2pa; shower pan inspection Date: July 18, 2012 Permit status: Complete | Completion date: August 17, 2012 | Expiration date: July 18, 2012 | Permit id: Pw20120718287 | |||||
Work category: 5p; second floor public restroom ada renovations. Date: March 19, 2012 Permit status: Expired | Expiration date: March 19, 2012 | Permit id: Pw20120319984 | |||||
Work category: 5p; re-route existing plumbing location for one sink. Date: July 5, 2011 Permit status: Expired | Expiration date: July 5, 2011 | Permit id: Pw20110705360 | |||||
Work category: 4pb; relocate 38 heads, add 9 heads and delete 13 heads, #1144349 Date: January 12, 2012 Permit status: Complete | Completion date: April 4, 2012 | Expiration date: January 12, 2012 | Permit id: Pw20120112695 | |||||
Work category: 5p; spa (includes toilet rooms, treatment sinks, pedicure chairs with rps) on the 3rd floor of the mandarin hotel. Date: June 8, 2012 Permit status: Complete | Completion date: August 17, 2012 | Expiration date: June 8, 2012 | Permit id: Pw20120608563 | |||||
Work category: 5p; renovation of hotel rooms converting to ada. Date: February 29, 2012 Permit status: Complete | Completion date: September 17, 2012 | Expiration date: February 29, 2012 | Permit id: Pw20120229620 | |||||
Work category: 5p; replacement of shower pan for room 4005. Date: May 1, 2012 Permit status: Complete | Completion date: May 9, 2012 | Expiration date: May 1, 2012 | Permit id: Pw20120501795 | |||||
Work category: 4pb; suite oriental- 11 heads, all relo 4 deletesuite taipan - 14 heads 8 relo 6 add 4 delete , total 25 #1244616 Date: July 6, 2012 Permit status: Complete | Completion date: July 19, 2012 | Expiration date: July 6, 2012 | Permit id: Pw20120706047 | |||||
Work category: 5p; first floor, adding mens and womens restroom. Date: May 7, 2012 Permit status: Complete | Completion date: June 11, 2012 | Expiration date: May 7, 2012 | Permit id: Pw20120507905 | |||||
Work category: 5p; renovation of model room. Date: August 5, 2011 Permit status: Complete | Completion date: September 8, 2011 | Expiration date: August 5, 2011 | Permit id: Pw20110805926 | |||||
Work category: 5p; rough-in for new lobby bar and restaurant Date: January 27, 2012 Permit status: Complete | Completion date: April 27, 2012 | Expiration date: January 27, 2012 | Permit id: Pw20120127980 | |||||
Work category: 4pb; fire sprinkler 3rd fl, #1244537 Date: June 25, 2012 Permit status: Complete | Completion date: July 19, 2012 | Expiration date: June 25, 2012 | Permit id: Pw20120625871 | |||||
SCORE 100 Add fcps panels to florrs 38 39 41. Add strobes to ada rooms 3801 3809 3818 3908 3916 3918 4001 4005 4006 4105 4106 4207 4304 4316 4416 4517 2nd floor add 3 speakers 3 strobes sd-44 & increase strobe candela to 1 on speaker/strobe add smoke detector above fcps on 44. Permit type: Building permit | Expiration date: October 11, 2012 | Current use: Tourist hotel/motel | Permit id: #201204118118 | |||||
SCORE 82 1 f: fire sprinkler t. I.: relocate 17 pendents remove 3 pendents. Ref t. I. Pa#201602189863 Permit type: Building permit | Expiration date: July 31, 2018 | Current use: Food/beverage hndlng | Permit id: #201801309899 | |||||
SCORE 100 Add 1 new speaker strobe 1 new duct detector. 1 control relay 2 replacement speakers to speaker/strobes 6 relocates speaker strobes Permit type: Building permit | Expiration date: September 12, 2012 | Current use: Food/beverage hndlng | Permit id: #201203125836 | |||||
Interior renovation @ hotel lobby stair elevator lobby. Includes m. E. P. Fire alarm separate permit. Maher: n a Date: March 9, 2017 Permit type: Building permit | Current use: Tourist hotel/motel | Permit id: #201703091093 | |||||
SCORE 100 Renovation of lobby front desk & grand area-expand restaurant & bar pantry of main lobby remove (e) bar clubroom & gift shop-2nd. Level-remove (e) restaurant & convert to meeting space. Permit type: Building permit | Expiration date: June 23, 2014 | Current use: Food/beverage hndlng | Permit id: #201111078433 | |||||
SCORE 100 Guestroom remodeling levels 38-48; mostly cosmetic. Extent of construction work is limited to relocation of some minor non-bearing walls upgrade 5% of total guestrooms to accessible units. Deletion/relocation of electrical outlets. Permit type: Building permit | Expiration date: May 17, 2014 | Current use: Tourist hotel/motel | Permit id: #201111098562 | |||||
SCORE 100 Interior renovation @ hotel lobby stair elevator lobby. Includes m. E. P. Fire alarm separate permit. Maher: n a Permit type: Building permit | Expiration date: November 7, 2019 | Current use: Tourist hotel/motel | Permit id: #201703091093 | |||||
SCORE 96 2nd floor ballrooms and floors of suites; mandarin hotel; cei job #11-4345 pc Date: February 17, 2012 Contractor: Cupertino Electric Inc Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20120217261 | |||||
SCORE 95 Install 44 data cables on the first floor lobby. Date: February 17, 2012 Contractor: Idex Global Services Inc Permit type: Electrical permit | Permit status: Issued | Permit id: E20120217869 | |||||
SCORE 95 Metro job #38293m - mandarin hotel lobby - (170) lights (20) switches (30) receptacles Date: January 27, 2012 Contractor: Metropolitan Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20120127122 | |||||
SCORE 100 Install projecting illuminated double faced sign Date: November 10, 2015 Contractor: Allen Thomas Ray Paul Permit type: Building permit | Permit id: #201511102200 | |||||
SCORE 95 Elevator project Date: October 30, 2014 Contractor: Mcmillan Bros Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20141030821 | |||||
SCORE 100 Suite #4612 & 4702-add 2 strobes in ada rooms #4612 & 4702-add booster panel in 47th floor housekeeping closet & smoke detector above it Permit type: Building permit | Expiration date: August 4, 2012 | Current use: Tourist hotel/motel | Permit id: #201204047492 | |||||
SCORE 100 Work category: 2pa; shower pan inspection on 38th floor Date: August 7, 2012 Contractor: Tile West Inc Permit type: Plumbing permit | Permit status: Issued | Permit id: Pw20120807725 | |||||
SCORE 100 Perform all mechanical electrical & plumbing work associated with relocation of fitness & hotel offices form 4th to 3rd floor. Ref pa #2012. 03. 28. 7008. Permit type: Building permit | Expiration date: May 15, 2014 | Current use: Tourist hotel/motel | Permit id: #201204118088 | |||||
SCORE 96 Work category: 6pa; install goslyn grds Date: April 28, 2014 Contractor: All Point Solutions Plumbing Co Permit type: Plumbing permit | Permit status: Issued | Permit id: Pw20140428717 | |||||
SCORE 100 Work category: 5p; renovation of model room. Date: August 5, 2011 Contractor: Bellanti Plumbing Inc Permit type: Plumbing permit | Permit status: Complete | Permit id: Pw20110805926 | |||||
SCORE 100 Work category: 4pb; fire sprinkler elevator modernization - remove sprinklers and pipe from elevator hoistway and machine room on roof Date: August 24, 2015 Contractor: Rlh Fire Protection Cma Fire Protect Permit type: Plumbing permit | Permit status: Issued | Permit id: Pw20150824727 | |||||
Interior renovation at restaurant and bar on level 1. N/a ordinance #155-13- new occupoant load- sffd permit required for assembly Date: February 18, 2016 Value: $850,000 Permit type: Building permit | Current use: Food/beverage hndlng | Permit id: #201602189863 | |||||
SCORE 100 1st floor - fire sprinkler only - relocate 38 heads add 9 heads delete 13 heads. For the mandarin oriental. Total 47 heads. Permit type: Building permit | Expiration date: July 11, 2012 | Current use: Food/beverage hndlng | Permit id: #201201112032 | |||||
SCORE 100 Work category: 4pb; relocate 38 heads add 9 heads and delete 13 heads #1144349 Date: January 12, 2012 Contractor: Rlh Fire Protection Cma Fire Protect Permit type: Plumbing permit | Permit status: Issued | Permit id: Pw20120112695 | |||||
SCORE 100 Work category: 5p; rough-in for new lobby bar and restaurant Date: January 27, 2012 Contractor: Bellanti Plumbing Inc Permit type: Plumbing permit | Permit status: Issued | Permit id: Pw20120127980 | |||||
SCORE 100 Model room review; modify 2-guestrm. Unit 3803 & 3804 for ownership to evaluate 2-separate schemes. Mostly cosmetic construction work is limited to deletion & relocation of 2-partial non-bearing walls & deletion relocation of elect. Outlets. Permit type: Building permit | Expiration date: January 26, 2012 | Current use: Tourist hotel/motel | Permit id: #201107250956 | |||||
SCORE 100 Work category: 5p; re-route existing plumbing location for one sink. Date: July 5, 2011 Contractor: Bayline Mechanical Inc Permit type: Plumbing permit | Permit status: Issued | Permit id: Pw20110705360 | |||||
SCORE 100 Work category: 2pa; shower pan inspection Date: July 18, 2012 Contractor: Tile West Inc Permit type: Plumbing permit | Permit status: Complete | Permit id: Pw20120718287 | |||||
SCORE 100 38th floor fire sprinkler only - suite - oriental : 11 heads all relo 4 deletes. Suite taipan: 14 heads 8 relocate 6 add 4 delete total 25 heads. Permit type: Building permit | Expiration date: January 5, 2013 | Current use: Tourist hotel/motel | Permit id: #201207054098 | |||||
SCORE 100 Work category: 5p; spa (includes toilet rooms treatment sinks pedicure chairs with rps) on the 3rd floor of the mandarin hotel. Date: June 8, 2012 Contractor: D P W Inc Permit type: Plumbing permit | Permit status: Issued | Permit id: Pw20120608563 | |||||
SCORE 100 Work category: 4pb; fire sprinkler 3rd fl #1244537 Date: June 25, 2012 Contractor: Rlh Fire Protection Cma Fire Protect Permit type: Plumbing permit | Permit status: Issued | Permit id: Pw20120625871 | |||||
SCORE 100 Work category: 5p; second floor public restroom ada renovations. Date: March 19, 2012 Contractor: Bellanti Plumbing Inc Permit type: Plumbing permit | Permit status: Issued | Permit id: Pw20120319984 | |||||
SCORE 100 3rd floor-fire sprinkler only-relocate 1 heads add 14 heads & remove 21 heads. 134 sprinklers Permit type: Building permit | Expiration date: May 18, 2013 | Current use: Tourist hotel/motel | Permit id: #201205180728 | |||||
SCORE 100 Work category: 5p; replacement of shower pan for room 4005. Date: May 1, 2012 Contractor: Bellanti Plumbing Inc Permit type: Plumbing permit | Permit status: Complete | Permit id: Pw20120501795 | |||||
SCORE 100 Work category: 5p; first floor adding mens and womens restroom. Date: May 7, 2012 Contractor: Bellanti Plumbing Inc Permit type: Plumbing permit | Permit status: Complete | Permit id: Pw20120507905 | |||||
SCORE 100 Canopy installation; replace (e) canopy @ entry with (n) design. Permit type: Building permit | Expiration date: May 23, 2012 | Current use: Tourist hotel/motel | Permit id: #201109164791 | |||||
Canopy installation; replace (e) canopy @ entry with (n) design. Date: September 16, 2011 Permit type: Building permit | Current use: Tourist hotel/motel | Permit id: #201109164791 | |||||
Interior renovation at restaurant and bar on level 1. N a ordinance #155-13- new occupoant load- sffd permit required for assembly Date: February 18, 2016 Value: $850,000 Permit type: Building permit | Current use: Food/beverage hndlng | Permit id: #201602189863 | |||||
SCORE 100 38/f 39/f 40/f 43/f -guestroom remodeling. Revision to appl#201111098562. Permit type: Building permit | Expiration date: April 26, 2013 | Current use: Tourist hotel/motel | Permit id: #201204178452 | |||||
SCORE 100 2nd level - provide new lighting & title -24 @ ballroom areas. Maher 155-13 na Permit type: Building permit | Expiration date: April 19, 2018 | Current use: Tourist hotel/motel | Permit id: #201704144033 | |||||
SCORE 100 Fire sprinkler elevator modernization remove heads in top of elevator hoistway and in machine room on roof (ab2. 01 add "d") no plan required. N/a ordinance #155-13 Permit type: Building permit | Expiration date: December 24, 2015 | Current use: Tourist hotel/motel | Permit id: #201508245081 | |||||
SCORE 100 Interior renovation at restaurant and bar on level1 includes mep -sprinklers fire alarm sep. Permitm c new occupoant load-n c maher ordinance no133. 13 Permit type: Building permit | Expiration date: December 28, 2018 | Current use: Food/beverage hndlng | Permit id: #201602189863 | |||||
SCORE 95 Electrical - this is an existing hotel lobby remodel with new lighting and branch power - 18181-lobby (not for restaurant) Date: February 13, 2018 Contractor: Capitol Electric Const Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201802131024 | |||||
SCORE 95 Electrical work - equipment installation - 18181 - lobby Date: January 11, 2018 Contractor: Capitol Electric Const Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201801110312 | |||||
SCORE 100 Work category: 2pa; plumbing for renovated bar. Date: January 17, 2018 Contractor: Bellanti Plumbing Inc Permit type: Plumbing permit | Permit status: Issued | Permit id: Pw20180117734 | |||||
SCORE 100 Work category: 4pb; 17 relocated pendants and 3 deleted pendents Date: January 30, 2018 Contractor: Rlh Fire Protection Cma Fire Protect Permit type: Plumbing permit | Permit status: Complete | Permit id: Pw20180130117 | |||||
SCORE 100 Work category: 4pb; suite oriental- 11 heads all relo/4 deletesuite taipan - 14 heads 8 relo/6 add/ 4 delete total 25 #1244616 Date: July 6, 2012 Contractor: Rlh Fire Protection Cma Fire Protect Permit type: Plumbing permit | Permit status: Complete | Permit id: Pw20120706047 | |||||
SCORE 86 Metro job #64756 panel boards (2) switches (3) circuits (24) Date: September 22, 2017 Contractor: Metropolitan Electrical Construction Permit type: Electrical permit | Permit status: Complete | Permit id: Ew201709188044 |