Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 97 Fico detached demo of 364 sf unpermitted habitable space, addition of 208 sf to existing barn, relocating laundry room (misc elec, pluming, mechanical) for exst sfd. Non-fico: 11 sf re-roof, electrical and plumbing repair re-wiring and panel upgrade for sfd, pool house and garage. 8 26 14--plan change-add reroof-see coa-lv 8 13 14--add on panel upgrade--lv existing roofing material: asphalt shingles proposed roofing material: asphalt shingles esr# 1372 manufacturer: owens cornings brand and model: oakridge color (if cool roof required): n a built-up roofing assembly system number per attached listing report (if applicable): specific exemption from cool roof requirements (if applicable): no ducts in attic required building inspector field verification (if applicable): no ducts in attic รก note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building insp Permit type: Building : 3281 - re | Permit status: Permit finaled | Completion date: October 17, 2014 | Permit id: Pds2014-Resacc- | |||||
SCORE 69 Fico detached demo of 364 sf unpermitted habitable space, addition of 208 sf to existing barn, relocating laundry room (misc elec, pluming, mechanical) for exst sfd. Non-fico 11 sf re-roof, electrical and plumbing repair/re-wiring and panel upgrade for sfd, pool house and garage. 8/26/14--plan change-add reroof-see coa-lv 8/13/14--add on panel upgrade--lv existing roofing material asphalt shingles proposed roofing material asphalt shingles esr# 1372 manufacturer owens cornings brand and model oakridge color (if cool roof required) n/a built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) no ducts in attic required building inspector field verification (if applicable) no ducts in attic note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspec Permit type: New residential acc structure | Permit status: Completed | Completion date: October 17, 2014 | Permit id: Pds2014-Resacc- | |||||
SCORE 100 Hvac change out - package system - - including misc. Elec. This project must comply with the current building energy efficiency standards. Registered title 24 forms must be provided to the inspector in the field. 06-10-2016 scope change to add misc. Elec. And mech. Maz Date: June 7, 2016 Contractor: A S I Hastings Inc Permit type: Residential alteration-addn | Permit status: Issued | Permit id: Pds2016-Resalt- | |||||
SCORE 100 Roof mount residential solar pv for existing sfd (no meter upgrade). Persection 46 (i) of the zoning ordinance, roof mounted photovoltaic systems shall not extend more than 5 ft. Above the highest point of the existing roof. Date: June 13, 2016 Contractor: N B Baker Electric Inc Permit type: Residential alteration-addn | Permit status: Completed | Completion date: June 28, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 69 Fico detached demo of 364 sf unpermitted habitable space, addition of 208 sf to existing barn, relocating laundry room (misc elec, pluming, mechanical) for exst sfd. Non-fico 11 sf re-roof, electrical and plumbing repair re-wiring and panel upgrade for sfd, pool house and garage. 8 26 14--plan change-add reroof-see coa-lv 8 13 14--add on panel upgrade--lv existing roofing material asphalt shingles proposed roofing material asphalt shingles esr# 1372 manufacturer owens cornings brand and model oakridge color (if cool roof required) n a built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) no ducts in attic required building inspector field verification (if applicable) no ducts in attic note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspec Permit type: New residential acc structure | Permit status: Completed | Completion date: October 17, 2014 | Permit id: Pds2014-Resacc- | |||||
SCORE 96 722 sq ft attached patio cover for (e) sfd. Permit type: Addn | Permit status: Completed | Completion date: October 11, 2017 | Permit id: Pds2017-Resalt- | |||||
Final Date: June 24, 2016 Permit status: Pass | Permit id: Pds2016-Resalt- | |||||
Final Date: October 16, 2014 Permit status: Pass | Permit id: Pds2014-Resacc- |