Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Dccr proposes to drill one geotechnical boring (rcagi-47) an alley located at the intersection of the alley and kennedy street at the listed address (22 kennedy st ne). The boring will be 12 inches diameter and feet bgs, drilled by vacuum excavation methods. A monitoring well will be installed in the boring. All drilling generated waste will be drummed (solids and liquids), tested and shipped offsite for disposal. In the event the well is not completed within 1 day, the well shall be covered protected from surface water drainage, and the vertical migration of contaminants and other materials through the well casing and well annulus. A locking well cap will be installed and the rig parked over the excavation to prohibit vandalism. If no monitoring well is installed, the boring will be abandoned following ddoe requirements. No drilling spoils or excavated soils will be used as backfill. The monitoring well or well abandonment will be completed the same day. See idw management plan and at Date: October 2, 2015 Client: Dc Water | Permit type: Excavation; monitoring well (single) | Permit status: Permit expired | Expiration date: March 31, 2016 | Permit id: Pa117043 | |||||
Installation of wrough iron fence on top of brick wall with brick columns. Installation of gate 42" wide. Date: May 18, 2016 Client: Will Gooding | Permit type: Fixture; fence to 42" (open w/brick piers) | Permit status: Issued | Expiration date: August 25, 2016 | Permit id: Pa157840 | |||||
SCORE 88 Installation of wrough iron fence on top of brick wall with brick columns. Installation of gate 42" wide. Date: May 18, 2016 Contractor: Ad And F Llc Client: Will Gooding | Permit type: Fixture; fence to 42" (open w/brick piers) | Permit status: Permit expired | Expiration date: August 25, 2016 | Permit id: Pa157840 | |||||
SCORE 100 Dccr proposes to drill one geotechnical boring (rcagi-47) an alley located at the intersection of the alley and kennedy street at the listed address (22 kennedy st ne). The boring will be 12 inches diameter and feet bgs, drilled by vacuum excavation methods. A monitoring well will be installed in the boring. All drilling generated waste will be drummed (solids and liquids), tested and shipped offsite for disposal. In the event the well is not completed within 1 day, the well shall be covered protected from surface water drainage, and the vertical migration of contaminants and other materials through the well casing and well annulus. A locking well cap will be installed and the rig parked over the excavation to prohibit vandalism. If no monitoring well is installed, the boring will be abandoned following ddoe requirements. No drilling spoils or excavated soils will be used as backfill. The monitoring well or well abandonment will be completed the same day. See idw management plan and at Date: October 2, 2015 Contractor: E2cr Inc Client: Dc Water | Permit type: Excavation; monitoring well (single) | Permit status: Permit expired | Expiration date: March 31, 2016 | Permit id: Pa117043 | |||||
SCORE 99 Construction staging area Date: October 30, 2015 Contractor: E2cr C O Siva Balu Permit status: Permit expired | Expiration date: December 5, 2015 | Permit id: Pa10215841 | |||||
SCORE 88 Construction staging area Date: July 18, 2016 Contractor: Ad And F Llc Permit status: Permit expired | Expiration date: August 25, 2016 | Permit id: Pa10312442 |