Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Mechanical permit Date: November 24, 2008 Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit status: Completed | Permit id: 189711 | |||||
Plumbing permit Date: July 9, 2008 Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit status: Completed | Permit id: 163520 | |||||
Addition permit Date: May 8, 2007 Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit status: Expired | Permit id: 28503 | |||||
Electrical permit Date: July 28, 2015 Client: Kaufmann Todd C Kaufmann Carolyn | Permit status: Completed | Permit id: 627805 | |||||
Alteration permit Date: December 10, 2012 Client: Anselmo Robert Stevens Jonathan | Permit status: Completed | Permit id: 442095 | |||||
Zoning permit Date: July 3, 2012 Client: Kaufmann Todd C Kaufmann Carolyn | Permit status: Completed | Permit id: 412452 | |||||
Addition permit Date: June 10, 2015 Client: Kaufmann Todd C Kaufmann Carolyn | Permit status: Completed | Permit id: 600511 | |||||
Administrative permit Date: October 21, 2008 Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit status: Completed | Permit id: 183726 | |||||
Zoning permit Date: March 31, 2015 Client: Kaufmann Todd C Kaufmann Carolyn | Permit status: Completed | Permit id: 594013 | |||||
Alteration permit Date: July 11, 2008 Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit status: Completed | Permit id: 163855 | |||||
Addition permit Date: July 3, 2012 Client: Kaufmann Todd C Kaufmann Carolyn | Permit status: Completed | Permit id: 412453 | |||||
Mechanical permit Date: August 12, 2015 Client: Kaufmann Todd C Kaufmann Carolyn | Permit status: Completed | Permit id: 631531 | |||||
Electrical permit Date: December 23, 2010 Client: Webb Herbert L Webb Cheryl A | Permit status: Expired | Permit id: 318095 | |||||
Plumbing permit Date: May 19, 2011 Client: Webb Herbert L Webb Cheryl A | Permit status: Completed | Permit id: 341994 | |||||
Addition permit Date: October 9, 2008 Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit status: Completed | Permit id: 163326 | |||||
Plumbing permit Date: December 3, 2012 Client: Anselmo Robert Stevens Jonathan | Permit status: Completed | Permit id: 441156 | |||||
Electrical permit Date: November 19, 2008 Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit status: Expired | Permit id: 189085 | |||||
Electrical permit Date: December 4, 2012 Client: Anselmo Robert Stevens Jonathan | Permit status: Completed | Permit id: 440815 | |||||
Permit for the erection of a 2nd floor addition above a 1 story detached garage 15x15 . Addition to be used as a dwelling unit. Garage and dwelling unit are on a lot with a 2 and 3 story attached townhouse. Date: September 30, 2010 Client: Webb Herbert L Webb Cheryl A | Applicant: Herbert Webb | Permit type: Appeal | Permit status: Denied | Permit id: 13469 | |||||
SCORE 100 Rerough bathroom,2 lav,1 sh,1 tub,1 wc (sfd) Date: December 3, 2012 Contractor: In A Flash Plumbing And Heating Client: Anselmo Robert Stevens Jonathan | Permit type: Plumbing permit | Permit status: Completed | Completion date: November 19, 2013 | Permit id: 441156 | |||||
SCORE 99 Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated february, 2007. Deviations from this standard will result in the revocation of this permit and imposition of further penalties." separate permits required for plumbing, electrical and mechanical work Date: December 10, 2012 Contractor: Victor Brubaker Client: Anselmo Robert Stevens Jonathan | Permit type: Alteration permit | Permit status: Completed | Completion date: November 19, 2013 | Permit id: 442095 | |||||
SCORE 100 Wiring of renovated bathroom on third floor- (4)switches, (10)recessed lights and (2)receptacles.... In accordance with 2008 nec for a one family building Date: December 4, 2012 Contractor: John Marcelis Jr Client: Anselmo Robert Stevens Jonathan | Permit type: Electrical permit | Permit status: Completed | Completion date: July 20, 2013 | Permit id: 440815 | |||||
Three story rear addition and interior alterations as per plans Date: October 9, 2008 Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit type: Addition permit | Permit status: Completed | Completion date: November 9, 2009 | Permit id: 163326 | |||||
For the erection of a third story addition at the rear of an existing three (3) story townhouse as per approved plans. For issuance of certificate of occupancy. Separate permits required for any m. E. P. Work. Date: June 10, 2015 Client: Kaufmann Todd C Kaufmann Carolyn | Permit type: Addition permit | Permit status: Completed | Completion date: February 23, 2016 | Permit id: 600511 | |||||
SCORE 99 Install 6-fixtures, 8-recepts, 3-switches, 1-230v a c line as per nec 2008 south district Date: July 28, 2015 Contractor: Gateway Electrical Contractors Client: Kaufmann Todd C Kaufmann Carolyn | Permit type: Electrical permit | Permit status: Completed | Completion date: November 19, 2015 | Permit id: 627805 | |||||
SCORE 100 Install (1) ductless mini split system (sfd) Date: August 12, 2015 Contractor: Francis Savarese Client: Kaufmann Todd C Kaufmann Carolyn | Permit type: Mechanical permit | Permit status: Completed | Completion date: February 23, 2016 | Permit id: 631531 | |||||
SCORE 100 Install new 2 amp service, install new lighting circuits, install new receptacle circuits, smoke detectors, phone and cable outlets, as per 2005 nec (south dist) Date: November 19, 2008 Contractor: Connextz Electrical Serv Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit type: Electrical permit | Permit status: Expired | Completion date: November 19, 2008 | Permit id: 189085 | |||||
SCORE 100 Install 2 gas hvac units and 1 heat pump Date: November 24, 2008 Contractor: Talgar Inc Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit type: Mechanical permit | Permit status: Completed | Completion date: November 9, 2009 | Permit id: 189711 | |||||
New roof deck, stairs and pilot house Date: July 3, 2012 Client: Kaufmann Todd C Kaufmann Carolyn | Permit type: Zoning permit | Permit status: Completed | Completion date: July 3, 2012 | Permit id: 412452 | |||||
For the erection of a 3rd floor rear addition above an existing two story portion of an attached structure. Size and location as shown in application. For use as an existing single family household living with one (1) existing open air parking space. Date: March 31, 2015 Client: Kaufmann Todd C Kaufmann Carolyn | Permit type: Zoning permit | Permit status: Completed | Completion date: March 31, 2015 | Permit id: 594013 | |||||
SCORE 93 Replace plumbing system Date: July 9, 2008 Contractor: Savemor Plumbing Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit type: Plumbing permit | Permit status: Completed | Completion date: December 22, 2008 | Permit id: 163520 | |||||
Building repairs to comply dangerous condition. See a p 163325 foe sealed plans Date: July 11, 2008 Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit type: Alteration permit | Permit status: Completed | Completion date: January 13, 2015 | Permit id: 163855 | |||||
Amend a p-163326 to reflect correct use ( two family dwelling) Date: October 21, 2008 Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit type: Administrative permit | Permit status: Completed | Completion date: November 9, 2009 | Permit id: 183726 | |||||
Two story rear addition Date: May 8, 2007 Client: Equitable Properties Inc | Client Company: Glen Rosenwald | Permit type: Addition permit | Permit status: Expired | Completion date: July 13, 2010 | Permit id: 28503 | |||||
SCORE 100 1 washine machine 1 kitchen sink,2 stack from basement up to roof replace part of main drain Date: May 19, 2011 Contractor: Richards Barrymore Client: Webb Herbert L Webb Cheryl A | Permit type: Plumbing permit | Permit status: Completed | Completion date: December 18, 2012 | Permit id: 341994 | |||||
SCORE 65 Replace 100amp 12 circuit panel with new 1 amp circuit panel, replace existing sws,outlets lights,install hard wire smoke detectors throughout property,upgrade circuit breakers with arc faults and gfis where required by code, as per 2008 nec (south dist) Date: December 23, 2010 Contractor: Derrick Rousseau Client: Webb Herbert L Webb Cheryl A | Permit type: Electrical permit | Permit status: Expired | Completion date: December 23, 2010 | Permit id: 318095 |