Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Suppression permit Date: March 29, 2011 Client: Vijapurapu Anantharao Vijapurapu Sudha | Permit status: Completed | Permit id: 327185 | |||||
Plumbing permit Date: September 9, 2011 Client: Joseph Galster | Permit status: Completed | Permit id: 362209 | |||||
Mechanical permit Date: March 9, 2011 Client: Vijapurapu Anantharao Vijapurapu Sudha | Permit status: Completed | Permit id: 328726 | |||||
New construction permit Date: August 2, 2011 Client: Joseph Galster | Permit status: Completed | Permit id: 351492 | |||||
Zoning use permit Date: December 8, 2010 Client: Vijapurapu Anantharao Vijapurapu Sudha | Permit status: Completed | Permit id: 315116 | |||||
Electrical permit Date: September 19, 2011 Client: Joseph Galster | Permit status: Completed | Permit id: 363506 | |||||
Zoning use permit Date: April 12, 2012 Client: John Manley Katherine Manley | Permit status: Completed | Permit id: 395455 | |||||
Zoning use permit Date: June 30, 2011 Client: Joseph Galster | Permit status: Completed | Permit id: 348704 | |||||
New construction permit Date: May 7, 2012 Client: John Manley Katherine Manley | Permit status: Expired | Permit id: 402382 | |||||
SCORE 96 For the construction of a three story structure to be a sfd. Date: December 8, 2010 Contractor: Obermayer Rebmann Maxwell Client: Japurapu Anantharao Vijapurapu Sudha | Permit type: Zoning/use permit | Permit status: Completed | Completion date: December 8, 2010 | Permit id: 315116 | |||||
New construction of 3 story wood frame single family dwelling with full cellar & flat roof as per plans. For the plan review approval, please see permit #321766 Date: February 2, 2011 Client: Japurapu Anantharao Vijapurapu Sudha | Permit type: New construction permit | Permit status: Completed | Completion date: August 29, 2011 | Permit id: 321888 | |||||
New construction of a new 3 story attached wood framed sfd. Date: April 12, 2012 Client: John Manley Katherine Manley | Permit type: Zoning/use permit | Permit status: Completed | Completion date: April 12, 2012 | Permit id: 395455 | |||||
Construction of a fully sprinkled 13d three story woodframed single family dwelling with flat roof and full cellar per submitted plan. Separate permits required for electric; plumbing; mechanical and sprinkler. Date: May 7, 2012 Client: John Manley Katherine Manley | Permit type: New construction permit | Permit status: Expired | Completion date: September 13, 2014 | Permit id: 402382 | |||||
SCORE 100 Install 1 hvac unit with associated ductwork (sfd) Date: March 9, 2011 Contractor: Talgar Inc Client: Japurapu Anantharao Vijapurapu Sudha | Permit type: Mechanical permit | Permit status: Completed | Completion date: August 29, 2011 | Permit id: 328726 | |||||
SCORE 100 Lateral Date: March 8, 2011 Contractor: Klein And Co Plumbing Inc Client: Japurapu Anantharao Vijapurapu Sudha | Permit type: Plumbing permit | Permit status: Completed | Completion date: August 29, 2011 | Permit id: 328598 | |||||
SCORE 100 Install 200amp service,install 25 circuit total,install 45 outlets,install switches,install 15 lights,install 8 120volt smoke detectors,install 2 phone cable jack as per 2008 nec Date: March 17, 2011 Contractor: Sean Kearns Client: Japurapu Anantharao Vijapurapu Sudha | Permit type: Electrical permit | Permit status: Completed | Completion date: September 6, 2011 | Permit id: 330391 | |||||
SCORE 100 Installation of a fire suppression system for sfd per plan & hyd. Cals. Date: March 29, 2011 Contractor: Fire Protection Services Inc Client: Japurapu Anantharao Vijapurapu Sudha | Permit type: Suppression permit | Permit status: Completed | Completion date: August 29, 2011 | Permit id: 327185 | |||||
SCORE 100 To install house drain waste line for 2 toilet,2 lav sinks,2 tubs,1 laudry box,1 kitchen sink,1 shower water supply and branch lines for all fixtures listed,set all fixture listed Date: March 3, 2011 Contractor: Garry Dabney Client: Japurapu Anantharao Vijapurapu Sudha | Permit type: Plumbing permit | Permit status: Completed | Completion date: August 29, 2011 | Permit id: 327865 | |||||
SCORE 100 Installation of nfpa 13r sprinkler system with 2" feed main Date: November 22, 2011 Contractor: Fire Protection Services Inc Permit type: Suppression permit | Permit status: Completed | Completion date: February 1, 2012 | Permit id: 365546 | |||||
SCORE 100 Install 200a svc,install 25 circuits,45 outlets, switches,15 lights,8-120v smokes,2 phone cables Date: September 19, 2011 Contractor: Sean Kearns Permit type: Electrical permit | Permit status: Completed | Completion date: February 17, 2012 | Permit id: 363506 | |||||
SCORE 100 Install house drain wast lines for 2 water closets, 2 lavys, 2 tubs, 1 laundry box, 1 kitchen sink, 1 shower - water supply and dranch lines for all fixtures listed and set all fixtures listed Date: September 9, 2011 Contractor: Garry Dabney Permit type: Plumbing permit | Permit status: Completed | Completion date: February 1, 2012 | Permit id: 362209 | |||||
SCORE 100 Install 1 hvac unit (sfd) Date: August 26, 2011 Contractor: Talgar Inc Permit type: Mechanical permit | Permit status: Completed | Completion date: February 1, 2012 | Permit id: 360044 | |||||
SCORE 99 Sewer lateral and water service outside only Date: September 6, 2011 Contractor: Keith Klein Permit type: Plumbing permit | Permit status: Completed | Completion date: February 1, 2012 | Permit id: 361589 | |||||
SCORE 96 For the construction of (5) sfds with cellar on each lot. Date: June 30, 2011 Contractor: Obermayer Rebmann Maxwell Permit type: Zoning/use permit | Permit status: Completed | Completion date: June 30, 2011 | Permit id: 348704 | |||||
SCORE 96 For the new construction of a 3 story wood framed single family dwelling with flat roof and full cellar per submitted plan. See a p # 351488 for plan review. Date: August 2, 2011 Contractor: Obermayer Rebmann Maxwell Permit type: New construction permit | Permit status: Completed | Completion date: January 27, 2012 | Permit id: 351492 |