Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Zoning/use permit ![]() Client: Phila Housing Authority | Client Company: Michael Johns | Permit status: Completed | Permit id: 716121 | |||||
Zoning use permit ![]() Client: Phila Housing Authority | Client Company: Michael Johns | Permit status: Completed | Permit id: 716121 | |||||
For the erection of a three (3) story structure, for use as a single family dwelling. Structure is frame construction and equipped with an automatic sprinkler system (nfpa 13d (minimum)). The proposed foundation is composed of a floor slab that is structurally supported by drilled-in helical piers. Separate permits will be required for the engineered truss drawings, plumbing, mechanical, electrical and fire suppression. A covered walkway or sidewalk closure shall be required within 8 feet of building facade in accordance with section 3306 of the ibc. Separate building and or streets department permits are required. ![]() Client: Philadelphia Housing Auth | Permit type: New construction permit | Permit status: Active | Completion date: October 18, 2017 | Permit id: 749143 | |||||
For the erection of an attached structure. Size and location as shown on plans application. For use as single family household living. ![]() Client: Philadelphia Housing Auth | Permit type: Zoning/use permit | Permit status: Completed | Completion date: August 18, 2016 | Permit id: 716121 | |||||
SCORE 100 Install new fire suppression system and 2" combined service in accordance with nfpa 13d throughout the entire building. All work shall comply with the approved plans. All work shall be performed by a fire suppression contractor licensed by the city of philadelphia. ![]() ![]() Client: Philadelphia Housing Auth | Permit type: Suppression permit | Permit status: Active | Completion date: September 20, 2017 | Permit id: 797147 | |||||
For the erection of an attached structure. Size and location as shown on plans application. For use as single family household living. ![]() Client: Philadelphia Housing Auth | Permit type: Zoning/use permit | Permit status: Completed | Completion date: March 1, 2017 | Permit id: 761851 | |||||
SCORE 100 Install 200amp service, complete grounding all new wiring with switches, lights, receptacles, 110v smoke detectors, co2 detectors, catv and tele wiring throughout the house as per 2008 (east district) ![]() ![]() Client: Philadelphia Housing Auth | Permit type: Electrical permit | Permit status: Active | Completion date: October 6, 2017 | Permit id: 822201 |