Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 100 Service change ![]() ![]() Client: Robert Knollenberg | Applicant: Crystal Electric Inc | Permit type: Electrical | Permit status: Cmp | Completion date: August 31, 2000 | Current use: Research & deve | |||||
SCORE 100 Hook-up existing transformer and panel. ![]() ![]() Client: Robert Knollenberg | Applicant: Crystal Electric Inc | Permit type: Electrical | Permit status: Cmp | Completion date: September 20, 2000 | Current use: Research & deve | |||||
SCORE 82 Replace existing roof top mechanical unit with same type and size unit. ![]() ![]() Client: Robert Knollenberg | Applicant: Robinson Mechanical Company | Permit type: Mechanical | Permit status: Cmp | Completion date: August 31, 2000 | Current use: Research & deve | |||||
SCORE 100 A c hookup ![]() ![]() Client: Robert Knollenberg | Applicant: Crystal Electric Inc | Permit type: Electrical | Permit status: Cmp | Completion date: September 9, 2000 | Current use: Service industr | |||||
SCORE 82 Replacing condensing unit ![]() ![]() Client: Robert Knollenberg | Applicant: Robinson Mechanical Company | Permit type: Mechanical | Permit status: Cmp | Completion date: August 30, 2000 | Current use: Office - admini | |||||
SCORE 95 Roofing permit for total tear off and overlay of 156 squares of dimensional shingles at a 1:12 slope. ![]() ![]() Client: South 1855.0 | Applicant: Black Roofing Inc | Permit type: Roofing | Permit status: Cmp | Completion date: December 3, 2008 | Current use: Manufacturing, | |||||
SCORE 100 @ central ave. & 55th- 1 2 trench and 2 access man holes - place 1 48" round man hole ![]() ![]() Client: South 1855.0 | Applicant: Qwest Comm/centurylink | Permit type: Right-of-way | Permit status: Iss | |||||
SCORE 95 Demo clean room and add new chiling coil unts etc. New doors ceilings etc. 5014 sf. No change in coverage or roof elevation. Client: South 1855.0 | Applicant: Howell Construction | Permit type: Building, electrical | Permit status: Cmp | Completion date: September 4, 2008 | Current use: Research & deve | |||||
SCORE 100 Replacement exhaust fan (20 cfm) and feet of replacement duct. (incresed cross section) ![]() ![]() Client: South 1855.0 | Applicant: Murphy Company Mech Cont & Eng | Permit type: Mechanical | Permit status: Cmp | Completion date: October 13, 2008 | Current use: Manufacturing, | |||||
SCORE 94 Mechanical permit - for comfort cooling - 3 ton mini-split. Outdoor unit to be placed under open stairs at southwest corner of building. ![]() ![]() Client: South 1855.0 | Applicant: Ultimate Heating & Cooling Llc | Permit type: Mechanical | Permit status: Cmp | Completion date: April 30, 2012 | Current use: Manufacturing, | |||||
SCORE 94 Installation of new mini-split rooftop heating and cooling unit. 33,1 btu heating adn 9,9 to 34,1 btu cooling, 14 seer rating. ![]() ![]() Client: South 1855.0 | Applicant: Ultimate Heating & Cooling, Llc | Permit type: Mechanical | Permit status: Cmp | Completion date: June 3, 2011 | Current use: Manufacturing, | |||||
SCORE 95 Fa - laboratory new system. Building owner wants fire alarm system to protect building. New adt. ![]() ![]() Client: South 1855.0 | Applicant: Tyco Integrated Security Llc | Permit type: Fire | Permit status: Cmp | Completion date: October 22, 2013 | Current use: Office - profes | |||||
SCORE 100 New underground from easement ![]() ![]() Client: South 1855.0 | Applicant: Comcast | Permit type: Right-of-way | Permit status: Iss | |||||
SCORE 95 Fa - addition ![]() ![]() Client: South 1855.0 | Applicant: Tyco Integrated Security Llc | Permit type: Fire | Permit status: Iss | Current use: Office - admini | |||||
SCORE 62 Electrical permit for installation of autoclave in existing lab. This is a inchsteris v116inch autoclave. Manufacturerfoots installation instructions to be available onsite during inspection. ![]() ![]() Client: South 1855.0 | Applicant: Prospect Electric Services Llc | Permit type: Electrical | Permit status: Cmp | Completion date: August 6, 2014 | Current use: Research & deve | |||||
SCORE 100 Fa - realm of caring ![]() ![]() Client: South 1855.0 | Applicant: Trident Security Systems | Permit type: Fire | Permit status: Cmp | Completion date: October 13, 2014 | Current use: Manufacturing, | |||||
SCORE 94 Mechanical permit - for comfort cooling - 3 ton mini-split. Outdoor unit to be placed under open stairs at southwest corner of building. Client: South | Permit type: Mechanical | Permit status: Cmp | Completion date: April 30, 2012 | Current use: Manufacturing, existing | Permit id: Pmt2009-02109 | |||||
SCORE 65 Installation of new mini-split rooftop heating and cooling unit. 33,1 btu heating adn 9,9 to 34,1 btu cooling, 14 seer rating. Client: South | Permit type: Mechanical | Permit status: Cmp | Completion date: June 3, 2011 | Current use: Manufacturing, existing | Permit id: Pmt2009-05155 | |||||
SCORE 95 Fa - addition Client: South | Permit type: Fire | Permit status: Iss | Current use: Office - administrative, existing | Permit id: Pmt2013-00784 | |||||
SCORE 100 A c hookup Client: Robert Knollenberg | Permit type: Electrical | Permit status: Cmp | Completion date: September 9, 2000 | Current use: Service industrial, existing | Permit id: Pmt2000-03218 | |||||
SCORE 62 Electrical permit for installation of autoclave in existing lab. This is a inchsteris v116inch autoclave. Manufacturerfoots installation instructions to be available onsite during inspection. Client: South | Permit type: Electrical | Permit status: Cmp | Completion date: August 6, 2014 | Current use: Research & development, existing | Permit id: Pmt2014-03242 | |||||
SCORE 100 Fa - realm of caring Client: South | Permit type: Fire | Permit status: Cmp | Completion date: October 13, 2014 | Current use: Manufacturing, existing | Permit id: Pmt2014-04381 | |||||
SCORE 95 Fa - laboratory new system. Building owner wants fire alarm system to protect building. New adt. Client: South | Permit type: Fire | Permit status: Cmp | Completion date: October 22, 2013 | Current use: Office - professional, existing | Permit id: Pmt2012-05036 | |||||
New underground from easement ![]() Client: South | Permit type: Right-of-way | Permit status: Iss | Permit id: Pmt2012-05988 | |||||
@ central ave. & 55th- 1 2 trench and 2 access man holes - place 1 48" round man hole ![]() Client: South | Permit type: Right-of-way | Permit status: Iss | Permit id: Pmt2007-04594 | |||||
SCORE 95 Tenant interior finish of a technical office suite. Scope includes new walls for private and open office spaces and breakroom, with new sink. Client: Bluff | Permit type: Building, electrical, mechanical, plumbing | Permit status: Iss | Current use: Office - technical, tenant remodel | Permit id: Pmt2017-01621 | |||||
SCORE 95 Demolition of entry and interior finish demolition of of existing office and lab space. Addition of new entry with ramp and elevator. Renovation of bathroom core and return of remainder of interior to gray shell for future tenant finish. Scope of work include site and landscape improvements. 01 19 2017 scope updated - maintaining existing lobby footprint. Removing existing entry and replacing with exterior upgrades. Mepfoots updated. Client: Bluff | Permit type: Building, electrical, mechanical, plumbing, flood fence flood permit, sitework | Permit status: Iss | Current use: Office - technical, addition and remodel | Permit id: Pmt2016-04159 | |||||
SCORE 100 Service change Client: Robert Knollenberg | Permit type: Electrical | Permit status: Cmp | Completion date: August 31, 2000 | Current use: Research & development, existing | Permit id: Pmt2000-02843 | |||||
SCORE 82 Replacing condensing unit Client: Robert Knollenberg | Permit type: Mechanical | Permit status: Cmp | Completion date: August 30, 2000 | Current use: Office - administrative, existing | Permit id: Pmt2000-03149 | |||||
SCORE 82 Replace existing roof top mechanical unit with same type and size unit. Client: Robert Knollenberg | Permit type: Mechanical | Permit status: Cmp | Completion date: August 31, 2000 | Current use: Research & development, existing | Permit id: Pmt2000-03296 | |||||
SCORE 100 Hook-up existing transformer and panel. Client: Robert Knollenberg | Permit type: Electrical | Permit status: Cmp | Completion date: September 20, 2000 | Current use: Research & development, existing | Permit id: Pmt2000-03323 | |||||
SCORE 95 Roofing permit for total tear off and overlay of 156 squares of dimensional shingles at a 1:12 slope. Client: South | Permit type: Roofing | Permit status: Cmp | Completion date: December 3, 2008 | Current use: Manufacturing, existing | Permit id: Pmt2007-04246 | |||||
@ central ave. & 55th- 1 2 trench and 2 access man holes - place 1 48inch round man hole ![]() Client: South | Permit type: Right-of-way | Permit status: Iss | Permit id: Pmt2007-04594 | |||||
SCORE 95 Demo clean room and add new chiling coil unts etc. New doors ceilings etc. 5014 sf. No change in coverage or roof elevation. Client: South | Permit type: Building, electrical, mechanical | Permit status: Cmp | Completion date: September 4, 2008 | Current use: Research & development, tenant remodel | Permit id: Pmt2008-01072 | |||||
SCORE 100 Replacement exhaust fan (20 cfm) and feet of replacement duct. (incresed cross section) Client: South | Permit type: Mechanical | Permit status: Cmp | Completion date: October 13, 2008 | Current use: Manufacturing, existing | Permit id: Pmt2008-03784 | |||||
SCORE 76 Fa - addition Client: South | Permit type: Fire | Permit status: Iss | Current use: Office - administrative, existing | Permit id: Pmt2013-00784 | |||||
SCORE 100 Structural repair-installation of (3) helical piers under existing columns that support an existing mezzanine. ![]() ![]() Client: Bluff | Permit type: Building | Permit status: Iss | Current use: Office - technical, repair | Permit id: Pmt2017-03255 | |||||
SCORE 95 Sign - alterations to an existing free-standing sign for inchflat iron parkinch directory. Aluminum and acrylic, non-electric, on an existing concrete base. ![]() ![]() Client: Bluff | Permit type: Flood fence flood permit, sign | Permit status: Den | Current use: Commercial/retail, existing | Permit id: Pmt2017-03579 | |||||
SCORE 95 Interior tenant remodel of an existing second floor office tenant space to reconfigure walls for separate offices, conference areas, and breakroom. Scope to also include addition of four new windows, one skylight, and a new corridor across adjoining future tenant spaces to a newly rated stair enclosure to the main level lobby. Client: Bluff | Permit type: Building, electrical, mechanical, plumbing | Permit status: Iss | Current use: Office - technical, tenant remodel | Permit id: Pmt2017-03634 | |||||
SCORE 95 Installation of eight new window openings on the southern wall of the structure ![]() ![]() Client: Bluff | Permit type: Building | Permit status: Iss | Current use: Office - technical, alteration | Permit id: Pmt2017-04175 | |||||
SCORE 95 Interior, non-structural tenant remodel of 397 sf. Constructing (4) new offices, (1) conference room and a kitchenette in the existing open space. Associated mepfoots covered within the scope of this permit. ![]() ![]() Client: Bluff | Permit type: Building, electrical, mechanical, plumbing | Permit status: Iss | Current use: Office - professional, tenant remodel | Permit id: Pmt2017-04293 |