Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 100 New construction:interior plumbing; five story building;assembly space first floor;office space second floor;twelve family dwelling third through fifth floor;12 water heaters, 12 full baths, 12 kitchen sinks, 12 washing machines, 12 dish washers, 1 sump pump - the installation will comply with the philadelphia plumbing code 2004 ![]() ![]() Permit type: Plumbing permit | Permit status: Active | Completion date: August 24, 2017 | Permit id: 804073 | |||||
Relocation of lot lines to create (1) lot. Demolition of existing 4th story. Proposed two story addition over existing (3) story building to create (5) stories. ![]() Permit type: Zoning permit | Permit status: Completed | Completion date: February 11, 2013 | Permit id: 426727 | |||||
SCORE 100 Install 6" lateral,curb trap,fai and 2" water line pa2017382341(multi family) ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: February 25, 2017 | Permit id: 758832 | |||||
SCORE 100 Install 1-fire panel, 10-smoke detectors, 40-horns, 9-pull stations, 18-horn strobes as per nfpa 72 (south district) ![]() ![]() Permit type: Electrical permit | Permit status: Expired | Completion date: April 21, 2017 | Permit id: 767366 | |||||
SCORE 100 Install new 600amp service complete with 16 meter stacks w 125amp tenet breakers,1 600amp 3phase service with a house panel and panel for commercial space with recepts, switches, lights, gfci rec, cable, intercom, smokes co detectors as per 2008 nec (south district) ![]() ![]() Permit type: Electrical permit | Permit status: Active | Completion date: October 18, 2017 | Permit id: 794852 | |||||
SCORE 96 Interior demo of non-load bearing walls, no structural work on this permit. ![]() ![]() Permit type: Demolition permit | Permit status: Completed | Completion date: May 1, 2015 | Permit id: 455928 | |||||
SCORE 100 For the complete demolition of structure. All permitted demolition activities to be in accordance with code bulletin no b-1302 and per approved site safty plan. Approved site safety plan shall be maintained on site at all times. Asbestos abatement to be completed prior to commencement of work. ![]() ![]() Permit type: Demolition permit | Permit status: Completed | Completion date: June 10, 2015 | Permit id: 572963 | |||||
SCORE 86 For the erection of a five story building with a assembly space on the first floor, an office space on the second floor level, and a twelve family dwelling from the third through fifth floor level. Building consists of two construction types: type ia for the basement through first floor and type va construction from the second through fifth floor. Please reference bbs case no. 25596 for provisos. Separate certificate of occupancy required for assembly and commercial space. Building to be fully sprinklered. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Separate permits required for mechanical, electrical, plumbing and fire suppression work. ![]() ![]() Permit type: New construction permit | Permit status: Active | Completion date: September 15, 2017 | Permit id: 608642 | |||||
SCORE 100 For the installation of a new fire suppression system design per nfpa 13 and new standpipes design per nfpa 14. For a new 4 inch fire service line as per plans. ![]() ![]() Permit type: Suppression permit | Permit status: Active | Completion date: August 24, 2017 | Permit id: 744637 |