Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 79 Repairs due to fire damage: 1 story freezer. Remove fire damaged wall panel east side. Replace with new. Permit type: Permit - easy permit | Permit id: 100222133 | |||||
SCORE 95 Install 400amp feed to panel, 2 - 200amp feeds to 2 compressors and 1 - 30amp feed for air dryer Permit type: Permit - electric wi | Permit id: 100326735 | |||||
SCORE 64 Removal and replacement same as existing hvac unit that serves the main office area. The new rtu is one york 12. 5 ton ,r410a, self contained, two compressors, located on the roof. Date: September 29, 2010 Contractor: Nestle Professional Vitality Permit type: Permit - easy permit | Permit id: 100365554 | |||||
SCORE 95 Extend 100a feed for roof top air conditioner replacing existing. Permit type: Permit - electric wi | Permit id: 100365598 | |||||
SCORE 65 Relocate the fireman's dump station. Date: October 4, 2010 Contractor: Nestle Vitality Permit type: Permit - easy permit | Permit id: 100366263 | |||||
SCORE 95 Tear-off and roof replacement using a sarnafil 60 mil f. A. Roofing system. There are four areas which include office and storage area. Permit type: Permit - easy permit | Permit id: 100370713 | |||||
SCORE 56 3124 sf tanker unloading building addition and electrical room addition as per plan Permit type: Permit - renovation/ | Permit id: 100393924 | |||||
SCORE 95 Updated power and control for glycol system. New amonia detection system. Value: $399,000 Contractor: The Best Guaranteed Elec. Cont Permit type: Permit - electric wi | Permit id: 100402860 | |||||
SCORE 100 Replace existing roof membrane (no structural work, no mep work)- all work same as existing; subject to field inspections Permit type: Permit - easy permit | Permit id: 100412723 | |||||
SCORE 95 New chilled water loop system to replace amonia. Amonia detection system to monitor remaining cooling equipment. Permit type: Permit - electric wi | Permit id: 100415135 | |||||
SCORE 95 Replace existing 2500a 120 240v 3p3w main service switchboard with new main breaker 2500amp switchboard. Disconnect and remove 2nd 3000amp service switchboard and refeed branch from new 2500amp service switchboard. Permit type: Permit - electric wi | Permit id: 100429393 | |||||
SCORE 65 Replacement of existing roof membrane with new insulated puc membrane. Same work as exixting. No structural work. Permit type: Permit - easy permit | Permit id: 100449569 | |||||
SCORE 95 Install one (1) 30a 240v circuit 3 phase for cip process skid. Install one (1) 20a 240v 3 phase circuit for return pump. Install one (1) 20a 120v circuit for sanitizing system. Install associated control wiring. Permit type: Permit - electric wi | Permit id: 100504890 | |||||
SCORE 56 Extend refrigerant relief line above catwalk. Replace three sight glasses. Replace 26 relief valves 16-hydrostatic, 10-atmospheric. Date: October 2, 2013 Contractor: Nestles Professional Beverage Permit type: Permit - easy permit | Permit id: 100511660 | |||||
SCORE 95 1. 0) furnish & install one (1) 20hp 240v feeder from existing 240v allen bradley mcc to new vfd location within mcc to facilitate field located tank seperation pump; installation shall include rigid steel conduit within mcc rrom, hardware, wiring, 50a 2100 series feeder bucket, install allenbradley power flex 70 vfd furnished by otehrs, & wiring terminations2. 0) mount one (1) customer provided control panel adjascent to mcc on unistrut floor stand rack within mcc room. Installation shall includ Permit type: Permit - electric wi | Permit id: 100514419 | |||||
SCORE 64 Tear off and replace roof Permit type: Permit - easy permit | Permit id: 100604020 | |||||
SCORE 95 Install 400amp feed to panel, 2 - 200amp feeds to 2 compressors and 1 - 30amp feed for air dryer Permit type: Permit - electric wiring | Permit id: 100326735 | |||||
SCORE 95 Extend 100a feed for roof top air conditioner replacing existing. Permit type: Permit - electric wiring | Permit id: 100365598 | |||||
SCORE 65 Relocate the firemans dump station. Date: October 4, 2010 Contractor: Nestle Vitality Permit type: Permit - easy permit process | Permit id: 100366263 | |||||
SCORE 95 New chilled water loop system to replace amonia. Amonia detection system to monitor remaining cooling equipment. Permit type: Permit - electric wiring | Permit id: 100415135 | |||||
SCORE 95 Replace existing 2500a 120 240v 3p3w main service switchboard with new main breaker 2500amp switchboard. Disconnect and remove 2nd 3000amp service switchboard and refeed branch from new 2500amp service switchboard. Permit type: Permit - electric wiring | Permit id: 100429393 | |||||
SCORE 95 Tear-off and roof replacement using a sarnafil mil f. A. Roofing system. There are four areas which include office and storage area. Permit type: Permit - easy permit process | Permit id: 100370713 | |||||
SCORE 95 Replace existing roof membrane (no structural work, no mep work)- all work same as existing; subject to field inspections Permit type: Permit - easy permit process | Permit id: 100412723 | |||||
SCORE 56 Addition of a 1-story industrial building to an existing manufacturing building for nestle-beverage processing area as per plans. Permit type: Permit - renovation/alteration | Permit id: 100631368 | |||||
SCORE 79 Repairs due to fire damage: 1 story freezer. Remove fire damaged wall panel east side. Replace with new. Permit type: Permit - easy permit process | Permit id: 100222133 | |||||
SCORE 64 Tear off and replace roof Permit type: Permit - easy permit process | Permit id: 100604020 | |||||
SCORE 95 Install one (1) 30a 240v circuit 3 phase for cip process skid. Install one (1) 20a 240v 3 phase circuit for return pump. Install one (1) 20a 120v circuit for sanitizing system. Install associated control wiring. Permit type: Permit - electric wiring | Permit id: 100504890 | |||||
SCORE 56 Interior alterations at 1st floor for per plans. Permit type: Permit - renovation/alteration | Permit id: 100680868 | |||||
SCORE 95 Low voltage fire alarm conduit and wiring to facilitate capital non-required fire alarm devices on existing system. Permit type: Permit - electric wiring | Permit id: 100672759 | |||||
SCORE 64 Removal and replacement same as existing hvac unit that serves the main office area. The new rtu is one york 12. 5 ton ,r410a, self contained, two compressors, located on the roof. Date: September 29, 2010 Contractor: Nestle Professional Vitality Permit type: Permit - easy permit process | Permit id: 100365554 | |||||
SCORE 95 Furnish and install motor power, control, instrumentation wiring from existing panel ha to field located drive and control panels a, b, c, d, e, f. Clarifier, briddo mixer flexicon conveyor admix and filler and conveyor equipment. Permit type: Permit - electric wiring | Permit id: 100660522 | |||||
SCORE 65 Replacement of existing roof membrane with new insulated puc membrane. Same work as exixting. No structural work. Permit type: Permit - easy permit process | Permit id: 100449569 | |||||
SCORE 95 1. 0) furnish & install one (1) 20hp 240v feeder from existing 240v allen bradley mcc to new vfd location within mcc to facilitate field located tank seperation pump; installation shall include rigid steel conduit within mcc rrom, hardware, wiring, 50a 21 series feeder bucket, install allen? Bradley power flex vfd furnished by otehrs, & wiring terminations2. 0) mount one (1) customer provided control panel adjascent to mcc on unistrut floor stand rack within mcc room. Installation shall include all galvanized unistrut, zinc hardware, and labor to mount. 3. 0) furnish & install one (1) dedicated 3? Phase 240v power dedicated pump feed from the new vfd unit located within mcc room, to the field located pump unit; installation shall include pvc coated rigid steel conduit to the field, hardware, wiring, & wiring terminations Permit type: Permit - electric wiring | Permit id: 100514419 | |||||
SCORE 100 Install low voltage equipment on roof Permit type: Permit - electric wiring | Permit id: 100728957 | |||||
SCORE 68 Tear down and remove brick chimney stack Permit type: Permit - easy permit process | Permit id: 100729043 | |||||
SCORE 56 Remove existing suspended ceiling tiles, grid, light, fixtures, wall ac units, abandon ductwork, original lath plaster ceilings and 11 interior doors, roof penetrations, no structural work. Electrical to be pulled under seperate permit Permit type: Permit - easy permit process | Permit id: 100732650 | |||||
SCORE 95 Electrical demolition in conjunction with building permit #100732650 Permit type: Permit - electric wiring | Permit id: 100732820 | |||||
SCORE 56 Remove and replace 12 ammonia evapoators with 12 fan coil units, install 2 ammonia to glycol heat exchangers and all associated piping as per stamped plans. Contact bob o'mara at 312-743-7215 for testing of ammonia piping. Date: April 21, 2011 Contractor: Nestles Professional Vitality Permit type: Permit - easy permit process | Permit id: 100390885 | |||||
SCORE 95 Updated power and control for glycol system. New amonia detection system. Value: $399,000 Contractor: The Best Guaranteed Elec. Cont Permit type: Permit - electric wiring | Permit id: 100402860 | |||||
SCORE 56 Interior build-out for new quality assurance laboratories. Build-out is 970 square feet to an existing beverage factory. Permit type: Permit - renovation/alteration | Permit id: 100505230 | |||||
SCORE 56 Interior buildout for an air compressor room and a chemical storage room for sanitation supplies and renovation of a drum sampling room to inspect product. These three rooms are located within the existing warehouse. Size of rooms are: air compressor room=925 square feet, chemical storare room=321 square feet and drum sampling room =120 square feet. Permit type: Permit - renovation/alteration | Permit id: 100515231 |