Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Mechanical permit Date: September 20, 2016 Client: Philadelphia City Propert | Permit status: Active | Permit id: 722697 | |||||
Zoning/use permit Date: May 6, 2016 Client: Philadelphia City Propert | Permit status: Completed | Permit id: 683076 | |||||
Zoning/use permit Date: August 12, 2015 Client: Philadelphia City Propert | Permit status: Completed | Permit id: 629726 | |||||
New construction permit Date: June 20, 2016 Client: Philadelphia City Propert | Permit status: Active | Permit id: 692517 | |||||
Zoning permit Date: December 18, 2012 Client: Philadelphia City Propert | Permit status: Completed | Permit id: 435897 | |||||
On 2/16/2016, the department of licenses and inspections issued a notice of refusal for application #660258. Date: February 24, 2016 Client: Philadelphia City Propert | Applicant: Anthony Maso | Permit type: Appeal | Permit status: Withdrawn | Permit id: 27078 | |||||
Zoning permit Date: December 18, 2012 Client: Metro Impact Llc | Permit status: Completed | Permit id: 444352 | |||||
New construction permit Date: June 20, 2016 Client: Philadelphia City Propert | Permit status: Active | Permit id: 692517 | |||||
Electrical permit Date: October 25, 2016 Client: Philadelphia City Propert | Permit status: Active | Permit id: 721532 | |||||
Zoning use permit Date: August 12, 2015 Client: Philadelphia City Propert | Permit status: Completed | Permit id: 629726 | |||||
Zoning use permit Date: May 6, 2016 Client: Philadelphia City Propert | Permit status: Completed | Permit id: 683076 | |||||
Plumbing permit Date: October 7, 2016 Client: Philadelphia City Propert | Permit status: Active | Permit id: 711145 | |||||
Suppression permit Date: October 4, 2016 Client: Philadelphia City Propert | Permit status: Active | Permit id: 725342 | |||||
Zoning permit Date: December 18, 2012 Client: Philadelphia City Propert | Permit status: Completed | Permit id: 435897 | |||||
Mechanical permit Date: September 20, 2016 Client: Philadelphia City Propert | Permit status: Active | Permit id: 722697 | |||||
On 2 16 2016, the department of licenses and inspections issued a notice of refusal for application #660258. Date: February 24, 2016 Client: Philadelphia City Propert | Applicant: Anthony Maso | Permit type: Appeal | Permit status: Withdrawn | Permit id: 27078 | |||||
SCORE 100 New construction: exterior & interior plumbing of a 4-story building with a pilot house on the roof and a roof deck, with (5) dwelling units. This permit includes a 6" sewer lateral & a 1" domestic water service to the street mains and a 1" backflow prevention containment assembly. Self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection". The installation shall comply with the philadelphia plumbing code, 2004. Date: October 7, 2016 Contractor: Tommys Plumbing Client: Philadelphia City Propert | Permit type: Plumbing permit | Permit status: Completed | Completion date: May 10, 2017 | Permit id: 711145 | |||||
SCORE 89 Install 400amp main electrical system and new wiring with outlets,switches,lights,smokes and co detectors as per 2008 nec (cc district) Date: October 25, 2016 Contractor: Affinity Technologies Inc Client: Philadelphia City Propert | Permit type: Electrical permit | Permit status: Completed | Completion date: May 15, 2017 | Permit id: 721532 | |||||
SCORE 100 For the installation of a two (2) inch fire service line with backflow preventor for the installation of an automatic fire suppression system per nfpa 13r. All work shall be done in accordance with approved plans and hydraulic calculations. Date: October 4, 2016 Contractor: Shannon Fire Protection Client: Philadelphia City Propert | Permit type: Suppression permit | Permit status: Completed | Completion date: May 17, 2017 | Permit id: 725342 | |||||
SCORE 93 Installation of (5) hvac units (including ductwork and all associated accessories). Self-contained units. No penetration of fire rated walls. No equipment on roof. Five multi-family dwellings. Date: September 20, 2016 Contractor: Angel Heating And Cooling Inc Client: Philadelphia City Propert | Permit type: Mechanical permit | Permit status: Completed | Completion date: May 10, 2017 | Permit id: 722697 | |||||
For the erection of a pilot house accessed by a roof deck ( nte sf) as part of previously approved structure for a multi-family household living ( five(5) dwelling units) in an existing structure. Size and location as shown in the application. Date: May 6, 2016 Client: Philadelphia City Propert | Permit type: Zoning/use permit | Permit status: Completed | Completion date: May 6, 2016 | Permit id: 683076 | |||||
New (4) story, (5) family dwelling with cellar, roof top deck accessed by a pilot house with a 6ft high fence. Units a & b are comprised of space in the cellar & ground floor, units c & d are on floor 2-4 Date: December 18, 2012 Client: Philadelphia City Propert | Permit type: Zoning permit | Permit status: Completed | Completion date: December 18, 2012 | Permit id: 435897 | |||||
New (4) story, (5) family dwelling with cellar, roof top deck accessed by a pilot house with a 6ft high fence. Units a & b are comprised of space in the cellar & ground floor, units c & d are on floor 2-4 Date: August 12, 2015 Client: Philadelphia City Propert | Permit type: Zoning/use permit | Permit status: Completed | Completion date: August 12, 2015 | Permit id: 629726 | |||||
For the erection of a four story building with a roof deck to provide maintenance to mechanical equipment accessed by a roof deck access structure. Structure for use as a five family dwelling. Building to be fully sprinklered. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Separate permits required for mechanical, electrical, plumbing and fire suppression work. Date: June 20, 2016 Client: Philadelphia City Propert | Permit type: New construction permit | Permit status: Completed | Completion date: May 17, 2017 | Permit id: 692517 | |||||
Zoning permit Date: December 18, 2012 Client: Metro Impact Llc | Permit status: Completed | Permit id: 444352 | |||||
New (4) story, (5) family dwelling with cellar, roof top deck accessed by a pilot house with a 6ft high fence. Units a & b are comprised of space in the cellar & ground floor, units c & d are on floor 2-4 Date: December 18, 2012 Client: Metro Impact Llc | Permit type: Zoning permit | Permit status: Completed | Completion date: December 18, 2012 | Permit id: 444352 |