Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Plumbing permit Date: September 16, 2015 Permit status: Active | Permit id: 631806 | |||||
Suppression permit Date: November 16, 2015 Permit status: Active | Permit id: 641452 | |||||
Administrative permit Date: September 1, 2016 Permit status: Active | Permit id: 712279 | |||||
Electrical permit Date: June 2, 2016 Permit status: Active | Permit id: 686427 | |||||
Zoning/use permit Date: July 21, 2015 Permit status: Completed | Permit id: 619267 | |||||
Alteration permit Date: July 21, 2015 Permit status: Active | Permit id: 619272 | |||||
Administrative permit Date: September 1, 2016 Permit status: Active | Permit id: 712279 | |||||
Zoning use permit Date: July 21, 2015 Permit status: Completed | Permit id: 619267 | |||||
Plumbing permit Date: September 16, 2015 Permit status: Active | Permit id: 631806 | |||||
Alteration permit Date: July 21, 2015 Permit status: Active | Permit id: 619272 | |||||
Electrical permit Date: June 2, 2016 Permit status: Expired | Permit id: 686427 | |||||
Suppression permit Date: November 16, 2015 Permit status: Active | Permit id: 641452 | |||||
Level ii alterations with partial change of occupancy to create four (4) tenant spaces from one (1) in an existing building, with space a to remain an existing warehouse and for the fit-out of space d to include erection of new mezzanine for a new warehouse space as per approved plans. Existing building fully sprinklered. Unlimited area building per ibc section 507. 4. Separate permits required to fit out space b and c prior to occupancy. Separate permits required for mep or fire suppression work Date: July 21, 2015 Permit type: Alteration permit | Permit status: Completed | Completion date: June 21, 2017 | Permit id: 619272 | |||||
SCORE 100 Installation of new lines, branch lines and sprinkler heads to exxtend an existing system in new office areas and below mezzanines in accordance with nfpa 13 in portions of an existing warehouse. System has existing fire pump. Date: November 16, 2015 Contractor: Legacy Fire Sprinkler Services Permit type: Suppression permit | Permit status: Completed | Completion date: June 21, 2017 | Permit id: 641452 | |||||
SCORE 89 Installation f 33 receptacles, 8 gfci receptacles, 16 emergency lights, 42 general light fixtures and swithces. Circuits to be ran to the 2 existing 2 amp panels located within the space as per 2008 nec (east district) Date: June 2, 2016 Contractor: Durian Electric Llc Permit type: Electrical permit | Permit status: Completed | Completion date: June 20, 2017 | Permit id: 686427 | |||||
SCORE 93 Amend permit number 619272 for revisions to mezzanine and access stair layout as per approved plans. Existing building fully sprinklered. Date: September 1, 2016 Contractor: 3stars Design And Build Ltd Permit type: Administrative permit | Permit status: Completed | Completion date: June 21, 2017 | Permit id: 712279 | |||||
SCORE 100 Install new waste and water supply for 4 water closets, 3 lavs, 1 urinal, 1 kitchen sink, 1 utility tub, and 1 mop sink. All work to comply with the 2004 ppc Date: September 16, 2015 Contractor: John J Bee,Inc Permit type: Plumbing permit | Permit status: Completed | Completion date: June 20, 2017 | Permit id: 631806 | |||||
For the erection of an interior mezzanine addition in space d (increase in gfa; no change to overall height or occupied area) of an existing semi-detached structure. Size and location as shown in application. For use as an existing warehouse in space a, a proposed warehouse in space b and d and a proposed limited industrial and warehouse in space c. No signs on this permit. Date: July 21, 2015 Permit type: Zoning/use permit | Permit status: Completed | Completion date: July 21, 2015 | Permit id: 619267 |