Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Zoning/use permit Date: August 31, 2015 Permit status: Completed | Permit id: 621047 | |||||
Plumbing permit Date: November 9, 2015 Permit status: Completed | Permit id: 650862 | |||||
Demolition permit Date: January 12, 2016 Permit status: Expired | Permit id: 663230 | |||||
Plumbing permit Date: April 14, 2016 Permit status: Active | Permit id: 683992 | |||||
New construction permit Date: December 7, 2016 Permit status: Active | Permit id: 665445 | |||||
Demolition permit Date: May 18, 2016 Permit status: Completed | Permit id: 663490 | |||||
Zoning use permit Date: August 31, 2015 Permit status: Completed | Permit id: 621047 | |||||
Zoning use permit Date: December 7, 2016 Permit status: Completed | Permit id: 738519 | |||||
Plumbing permit Date: November 9, 2015 Permit status: Completed | Permit id: 650862 | |||||
Plumbing permit Date: April 14, 2016 Permit status: Active | Permit id: 683992 | |||||
SCORE 96 Sealing lateral pa20153012073 (multi family)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" Date: November 9, 2015 Contractor: Frankie D And Benny G Plumbing And Permit type: Plumbing permit | Permit status: Completed | Completion date: December 9, 2015 | Permit id: 650862 | |||||
SCORE 93 Interior demolition ez interior demolition- for the interior demolition of non load-bearing partition walls and ceilings as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: January 12, 2016 Contractor: Rlc Contractors Inc Permit type: Demolition permit | Permit status: Completed | Completion date: January 25, 2017 | Permit id: 663230 | |||||
For the erection of a four (4) story structure for use as multi-family household living. Entire building to be fully sprinklered per nfpa 13 due to exterior wall openings. Separate permit reqd for mep and fire suppression work. A covered walkway or sidewalk closure shall be required within feet of building facade in accordance with section 3306 of the ibc. Separate building and or streets department permits are required. Date: December 7, 2016 Permit type: New construction permit | Permit status: Active | Completion date: August 9, 2017 | Permit id: 665445 | |||||
For the complete demoltion of an attached three-story structure with one-story portion. Full sidewalk and street closure required as reflected on approved site plan and in accordance with section 3306 of the ibc. Separate street closure permit required prior to start of work. Any deviation will require an amended building permit. Date: May 18, 2016 Permit type: Demolition permit | Permit status: Completed | Completion date: January 3, 2017 | Permit id: 663490 | |||||
SCORE 93 New contruction: interior plumbing; 4 story building; 4 family dwelling - the installation will comply with the philadephia plubming code 2004 Date: August 24, 2017 Contractor: Oleg Kapkanov Permit type: Plumbing permit | Permit status: Active | Completion date: September 14, 2017 | Permit id: 800544 | |||||
SCORE 86 New 400amp service complete with 5 meters, 5 panels & grounding, wire 4 apartments with switches, hi hats, recepts, bb smokes co detectors, door bell, phone & cable as per 2008 nec (east district) isntall fire alarm system as per nfpa72 Date: August 7, 2017 Contractor: Sigma Electric Group Inc Permit type: Electrical permit | Permit status: Active | Completion date: August 7, 2017 | Permit id: 796848 | |||||
SCORE 100 Automatic sprinkler system install w. Two (2) inch fire service line & backflow prevention (bfp) assembly to serve previously approved four (4) story above grade plane, w. Basement, multi-family dwelling. Automatic sprinkler system install per nfpa 13. Date: July 28, 2017 Contractor: Brothers Mechanical Permit type: Suppression permit | Permit status: Active | Completion date: August 18, 2017 | Permit id: 794336 | |||||
SCORE 100 Seal lateral pa20161041337 self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" Date: April 14, 2016 Contractor: Norman Cole Sr, Permit type: Plumbing permit | Permit status: Active | Completion date: October 20, 2017 | Permit id: 683992 | |||||
For the complete demolition of an existing attached structure. For the erection of an attached structure with one interior accessory parking space, 2nd floor deck, roof decks, and roof deck access structures. Size and and location as shown on application plans. For use as a multi-family (four (4) dwelling units) household living. Date: August 31, 2015 Permit type: Zoning/use permit | Permit status: Completed | Completion date: August 31, 2015 | Permit id: 621047 | |||||
Amend permit #621047 to document removal of roof deck access structure and roof deck. Size and location as shown on application plan. No change to previously approved use of multi-family (four dwelling units) household living. Date: December 7, 2016 Permit type: Zoning/use permit | Permit status: Completed | Completion date: December 7, 2016 | Permit id: 738519 | |||||
SCORE 93 Install 4 hvac units with ductwork (four-family dwelling) Date: October 24, 2017 Contractor: Igs Services Llc Permit type: Mechanical permit | Permit status: Active | Completion date: November 14, 2017 | Permit id: 826611 |