Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Zoning/use permit Date: October 17, 2007 Client: Ben-Moyal Abraham | Permit status: Completed | Permit id: 106227 | |||||
Demolition permit Date: October 17, 2007 Client: Ben-Moyal Abraham | Permit status: Completed | Permit id: 106229 | |||||
Demolition permit Date: October 17, 2007 Client: Ben-Moyal Abraham | Permit status: Completed | Permit id: 106229 | |||||
Zoning use permit Date: October 17, 2007 Client: Ben-Moyal Abraham | Permit status: Completed | Permit id: 106227 | |||||
SCORE 100 For the erection of a three story structure for use as a single family dwelling with roof decks accessed by roof deck access structure. Building to be sprinklered. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Separate permits required for mechanical, electrical, plumbing and fire suppression work. A covered walkway or sidewalk closure shall be required within 9 feet of the building facade in accordance with section 3306 of the 2009 ibc. Separate building and or streets department permit required prior to the start of any work. All above ground work to be done within property lines. Date: September 15, 2017 Contractor: Green Tree Group Contracting Permit type: New construction permit | Permit status: Active | Completion date: October 4, 2017 | Permit id: 791932 | |||||
SCORE 89 Installation of a one (1) inch combined service line for a fire & domestic supply line. For a multipurpose residential fire sprinkler system in accordance with nfpa 13d in a 3-story structure with pilot house (single family). Separate permit require for all plumbing work Date: November 22, 2017 Contractor: Aqueduct Fire Protection Permit type: Suppression permit | Permit status: Active | Completion date: November 22, 2017 | Permit id: 810498 | |||||
For the erection of an attached structure with a roof deck accessed by a roof deck access structure. Size and location as shown per application plan. Structure for use as a single family household living. Date: September 15, 2017 Permit type: Zoning/use permit | Permit status: Completed | Completion date: September 15, 2017 | Permit id: 791918 | |||||
Complete demolition. No demolition prior to nov. 7, 2007 Date: October 17, 2007 Permit type: Demolition permit | Permit status: Completed | Completion date: June 11, 2013 | Permit id: 106229 | |||||
Complete demolition Date: October 17, 2007 Permit type: Zoning/use permit | Permit status: Completed | Completion date: October 24, 2007 | Permit id: 106227 | |||||
SCORE 82 3-water closets, 4 lavs, 1 shower, 1 bathtub, 1kitchen sink, 1-washer box, pex and pvc throughout,new 1"rfss, new 5" lateral, 5x4 curb trap and 4" main drain as per philadelphia 2004 plumbing code. Date: December 1, 2017 Contractor: Frankie D Plumbing And Heating Permit type: Plumbing permit | Permit status: Active | Completion date: December 1, 2017 | Permit id: 835996 | |||||
SCORE 98 New construction electrical wiring including 200amp service all outlets and switches smoke detectors lighting all grounding all phase done per nec code Date: September 15, 2017 Contractor: Talon Electric Llc Permit type: Electrical permit | Permit status: Active | Completion date: September 15, 2017 | Permit id: 816635 | |||||
SCORE 89 Install (1) hvac system with ductwork. (sfd) Date: December 12, 2017 Contractor: Alkaun Co Permit type: Mechanical permit | Permit status: Active | Completion date: December 12, 2017 | Permit id: 838784 |