Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Zoning/use permit ![]() Permit status: Completed | Permit id: 657025 | |||||
Use permit ![]() Permit status: Completed | Permit id: 487206 | |||||
Plumbing permit ![]() Permit status: Completed | Permit id: 544940 | |||||
Mechanical permit ![]() Permit status: Expired | Permit id: 527431 | |||||
Administrative permit ![]() Permit status: Completed | Permit id: 550279 | |||||
Electrical permit ![]() Permit status: Active | Permit id: 670959 | |||||
Alteration permit ![]() Permit status: Completed | Permit id: 498949 | |||||
Alteration permit ![]() Permit status: Completed | Permit id: 402445 | |||||
Suppression permit ![]() Permit status: Completed | Permit id: 658401 | |||||
Use permit ![]() Permit status: Completed | Permit id: 521165 | |||||
Suppression permit ![]() Permit status: Completed | Permit id: 542665 | |||||
Plumbing permit ![]() Permit status: Completed | Permit id: 632904 | |||||
Administrative permit ![]() Permit status: Completed | Permit id: 633742 | |||||
Use permit ![]() Permit status: Completed | Permit id: 593405 | |||||
Sign permit ![]() Permit status: Completed | Permit id: 680549 | |||||
Alteration permit ![]() Permit status: Completed | Permit id: 571716 | |||||
Electrical permit ![]() Permit status: Completed | Permit id: 402835 | |||||
Mechanical permit ![]() Permit status: Completed | Permit id: 634051 | |||||
Suppression permit ![]() Permit status: Completed | Permit id: 670630 | |||||
Electrical permit ![]() Permit status: Expired | Permit id: 640713 | |||||
Electrical permit ![]() Permit status: Completed | Permit id: 542573 | |||||
Zoning permit ![]() Permit status: Completed | Permit id: 517998 | |||||
On 03/23/2015, the department of licenses and inspections issued notice of refusal for #593409. ![]() Applicant: Eimer Design | Permit type: Appeal | Permit id: 24904 | |||||
Plumbing permit ![]() Permit status: Completed | Permit id: 529981 | |||||
Administrative permit ![]() Permit status: Completed | Permit id: 548277 | |||||
Electrical permit ![]() Permit status: Completed | Permit id: 640713 | |||||
Alteration permit ![]() Permit status: Completed | Permit id: 571716 | |||||
Mechanical permit ![]() Permit status: Completed | Permit id: 652428 | |||||
Electrical permit ![]() Permit status: Completed | Permit id: 402835 | |||||
Use permit ![]() Permit status: Completed | Permit id: 593405 | |||||
Zoning permit ![]() Permit status: Completed | Permit id: 517998 | |||||
Alteration permit ![]() Permit status: Completed | Permit id: 402445 | |||||
Use permit ![]() Permit status: Completed | Permit id: 487206 | |||||
Suppression permit ![]() Permit status: Completed | Permit id: 670630 | |||||
Electrical permit ![]() Permit status: Completed | Permit id: 542573 | |||||
Mechanical permit ![]() Permit status: Completed | Permit id: 527431 | |||||
Suppression permit ![]() Permit status: Completed | Permit id: 542665 | |||||
Sign permit ![]() Permit status: Completed | Permit id: 680549 | |||||
Zoning use permit ![]() Permit status: Completed | Permit id: 657025 | |||||
Use permit ![]() Permit status: Completed | Permit id: 521165 | |||||
Administrative permit ![]() Permit status: Completed | Permit id: 633742 | |||||
Plumbing permit ![]() Permit status: Completed | Permit id: 632904 | |||||
Alteration permit ![]() Permit status: Completed | Permit id: 498949 | |||||
Suppression permit ![]() Permit status: Completed | Permit id: 658401 | |||||
Electrical permit ![]() Permit status: Completed | Permit id: 670959 | |||||
On 03 23 2015, the department of licenses and inspections issued notice of refusal for #593409. ![]() Applicant: Eimer Design | Permit type: Appeal | Permit id: 24904 | |||||
For the installation of one illuminated flat wall sign per submitted plan. Separate permit for electric may be required. ![]() Permit type: Sign permit | Permit status: Completed | Completion date: April 18, 2016 | Permit id: 680549 | |||||
Installation of one (1) accessory illuminated flat wall sign with 67"l x 13"h, all existing will be removed, ![]() Permit type: Zoning/use permit | Permit status: Completed | Completion date: February 8, 2016 | Permit id: 657025 | |||||
SCORE 86 Ez standard kitchen fire suppression- for the installation of new wet chemical kitchen hood fire suppression system as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: February 24, 2016 | Permit id: 658401 | |||||
Shelter platform permit- erection of a sidewalk shelter platform as per engineered plans. Streets department permit required for sidewalk closure prior to the start of work. ![]() Permit type: Alteration permit | Permit status: Completed | Completion date: December 29, 2015 | Permit id: 653338 | |||||
SCORE 86 Installation of type 1 hood systems (2) sizes and sections as shown on plans, with associated duct work, fire wrap insulation, exhaust and supply and fans. See prior mechanical approval ap634051 for fans, additional installations. Additional ansul fire system permits required. ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: February 24, 2016 | Permit id: 652428 | |||||
Permit for limited stabilization of fire damaged building. Repair limited to that which are outlined within the attached structural report prepared by the kachele group and may not exceed the scope of work outlined within the report. Separate permits will be required for all additional work to be performed. ![]() Permit type: Alteration permit | Permit status: Completed | Completion date: October 7, 2013 | Permit id: 402445 | |||||
SCORE 95 Temp permit 5 2 12 to 8 2 12:refeed alarm panel w 20amp circuit from 17 as per 2008 nec (mixed) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: June 13, 2012 | Permit id: 402832 | |||||
SCORE 95 Temp permit from 5 2 12 to 8 2 12;safe off from fire area and turn service on ;install gfci as per 2008 nec ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: June 13, 2012 | Permit id: 402835 | |||||
Use basement as commercial as allowed in cmx-5, 1st and mezzanine commercial as per cmx-5 and 2nd and 3rd floor to be multi-family (3) apts. ![]() Permit type: Use permit | Permit status: Completed | Completion date: August 22, 2013 | Permit id: 487206 | |||||
For a partial change in use and occupancy classification. Level iii alterations and structural work as per approved plans to vacant commercial space in basement, 1st floor and mezzanine (use registration permit required prior to occupancy and separate permit reqd for certificate of occupancy) and to create three (3) family dwelling. No change in height or area. Replacement of windows in existing exterior wall openings (no increase in size of exterior wall openings). Separate permit required for mechanical, electrical, plumbing, and fire suppression work. ![]() Permit type: Alteration permit | Permit status: Completed | Completion date: September 24, 2015 | Permit id: 498949 | |||||
For relocation of lot lines to create one (1) lot from two (2) lots (size and location as shown in the application). ![]() Permit type: Zoning permit | Permit status: Completed | Completion date: July 2, 2014 | Permit id: 517998 | |||||
For vacant commercial space in basement, 1st floor and mezzanine (use registration permit required prior to occupancy) and three (3) family dwelling above in an existing structure. No change in height or area. No sign on this application. ![]() Permit type: Use permit | Permit status: Completed | Completion date: March 14, 2014 | Permit id: 521165 | |||||
SCORE 100 Install plumbing for 3 apts,4 wc,4 lavs,4 showers,3 kitchen sinks,3 wm,3 water heater and 3 dishwashers (mixed use) ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: February 20, 2015 | Permit id: 529981 | |||||
SCORE 100 Alterations to existing hvac system as per approved plans. ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: November 25, 2016 | Permit id: 527431 | |||||
SCORE 95 New wiring in apartments on 2nd and 3rd floors, smokes and co2 detectors, new service cables and 100amp to each apartment, existing 600amp as per 2008 nec (cc district) no fire alarm system on this permit! ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: April 23, 2015 | Permit id: 542573 | |||||
SCORE 100 Install new fire suppression system in accordance with nfpa 13 and 13-r throughout the entire building. All work shall comply with the approved plans. All work shall be performed by a fire suppression contractor licensed by the city of philadelphia. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: January 26, 2015 | Permit id: 542665 | |||||
SCORE 64 Exterior brick pointing as per manufactures specification. ![]() ![]() Permit type: Alteration permit | Permit status: Completed | Completion date: August 8, 2014 | Permit id: 544195 | |||||
SCORE 89 Water service pa20141701676 (mixed use)"self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: June 30, 2014 | Permit id: 544940 | |||||
Amend existing permit ap#498949 & 550279 for tco. No work on this permit. ![]() Permit type: Administrative permit | Permit status: Completed | Completion date: February 17, 2015 | Permit id: 548277 | |||||
T c o for sit down resturant, basement and 1st floor.(parent permit #593409) ![]() Permit type: Administrative permit | Permit status: Completed | Completion date: February 19, 2016 | Permit id: 670558 | |||||
SCORE 100 Lower heads on 1st floor to meet new ceiling elevationsez permit sprinkler relocation (nfpa 13)- for the relocation of sprinkler heads as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: February 29, 2016 | Permit id: 670630 | |||||
SCORE 95 Replace fire alarm system in restaurant as per nfpa-72. (cc district) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: October 14, 2016 | Permit id: 670959 | |||||
Temporary certificate of occupancy ![]() Permit type: Administrative permit | Permit status: Active | Completion date: June 29, 2017 | Permit id: 790945 | |||||
SCORE 64 Amend building permit 498949 - work to include reinforcing 3rd floor, new floor opening between 1st floor and mezzanine, temporary railing, structural (framing) work, and temporary fire rated enclosure as per approved plans. See ap 498949 for co. ![]() ![]() Permit type: Administrative permit | Permit status: Completed | Completion date: February 17, 2015 | Permit id: 550279 | |||||
SCORE 96 For excavation of basement to install new underpinning at existing stone foundation walls, new concrete footings, and new thickened concrete slabs. Special inspector to be on site for proposed underpinning work. Separate administrative permit required for documentation of special inspector performing steel and concrete inspection items. ![]() ![]() Permit type: Alteration permit | Permit status: Completed | Completion date: April 28, 2015 | Permit id: 571716 | |||||
SCORE 96 New tenant will be opertationg a restaurant within the existing demised space. Previous use was also a restaurant. Space is zoned cmx-5. No signage on this permit. ![]() ![]() Permit type: Use permit | Permit status: Completed | Completion date: February 4, 2016 | Permit id: 593405 | |||||
SCORE 96 Level ii interior alterations on the basement and first floor of an existing structure to include demolition of partial existing rubble stone foundation wall, demolition of interior partions, stairs and ramps, and removal of existing entry window and awning. For construction of new interior partitions, storefront system, stairs, plumbing fixtures, lighting, food service equipment and new finishes as per approved plans. Separate permits required for mechanical, electrical and plumbing work l. O of maximum persons as per bbs variance, case # 24904 ![]() ![]() Permit type: Alteration permit | Permit status: Completed | Completion date: November 15, 2016 | Permit id: 593409 | |||||
SCORE 100 Relocate main and lower (6) heads. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: March 1, 2016 | Permit id: 614362 | |||||
Administrative permit for a temporary certificate of occupancy for days. Alteration permit #498949. Extension of temp co #548277 amend existing permit ap 498949 and 550279 for tco. No work on this permit ![]() Permit type: Administrative permit | Permit status: Completed | Completion date: September 8, 2016 | Permit id: 633742 | |||||
SCORE 100 Plumbing alterations in the basement and 1st floor for a sit-down restaurant - installation will comply with the approved plans, phila plumbing code 2004 tables p-811. 2 & p-904. 7 and backflow isolation devices will comply with table 608. 1 of the international plumbing code 2009 ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: February 24, 2016 | Permit id: 632904 | |||||
SCORE 100 Installation of hvac and related ductwork, registers grilles as per plans. ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: February 24, 2016 | Permit id: 634051 | |||||
SCORE 100 Install branch circuit wiring for power and lighting. Install fixtures and branch circuit wiring for kitchen equipment per 2008 nec (restaurant) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: November 15, 2016 | Permit id: 640713 |