Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Zoning/use permit Date: September 16, 2016 Client: Redevelopment Authority O | Permit status: Completed | Permit id: 695482 | |||||
Zoning use permit Date: September 16, 2016 Client: Redevelopment Authority O | Permit status: Completed | Permit id: 695482 | |||||
SCORE 100 Install new 5" lateral,curb trap,fai,1. 5 water service and 3 4 water service pa20171990994 (mixed use) "self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" Date: August 10, 2017 Contractor: Drain Masters Plumbing Llc Permit type: Plumbing permit | Permit status: Completed | Completion date: September 21, 2017 | Permit id: 804991 | |||||
SCORE 89 For the installation of a new mechanical system to serve the residential units on the 2nd-4th floors of a new structure. System to include heat pumps, ductwork, fans, registers, diffusers. All work per approved plans. Date: June 30, 2017 Contractor: Sanks Mechanical Permit type: Mechanical permit | Permit status: Completed | Completion date: September 7, 2017 | Permit id: 790699 | |||||
SCORE 79 New construction: interior plumbing for a 4-story attached structure with a roof access structure and vacant commercial space on the 1st floor with (2) dwelling units above (mixed-use). Additional permit are required for the 6" sewer lateral and the 1" domestic water distribution service to the street mains, as well as the 1" backflow prevention containment assembly. Additional permits are required for the fit-out of the vacant commercial space on the 1st floor, except for the work shown on these approved plans, is included in this permit. Date: July 12, 2017 Contractor: Gaceta Plumbing Llc Permit type: Plumbing permit | Permit status: Completed | Completion date: September 6, 2017 | Permit id: 787624 | |||||
Co for two-family dwelling on 2nd-4th floors only for the erection of a new, four (4) story attached structure with roof deck and pilot house (to enclose access stairs only), to be used as vacant commercial space on the first floor (use registration and certificate of occupancy required prior to occupancy), with two-family household living above, as per plans; separate permits required for any and all mechanical, electrical, plumbing, and fire suppression work; first floor to be sprinklered as per nfpa 13; second-fourth floors to be sprinklered with nfpa 13r; class i standpipes to be installed within exit stairs as per nfpa 14. Date: April 12, 2017 Permit type: New construction permit | Permit status: Completed | Completion date: September 21, 2017 | Permit id: 767787 | |||||
For the erection of an attached structural (height nte 55 feet) with pilothouse (height nte feet; to enclose access stairs only), to access roof deck with 42-inch guard rails. Size and location as shown in the application plans. For use as vacant commercial on cellar and first floor (use registration required prior to occupancy) and household living (two-family dwelling) on floors 2-4. Roof deck accessory to residential units only Date: September 16, 2016 Permit type: Zoning/use permit | Permit status: Completed | Completion date: March 13, 2017 | Permit id: 695482 | |||||
SCORE 76 For the installation of a 2-inch fire service line for an automatic fire suppression sprinkler system with a backflow prevention assembly in accordance with nfpa 13r. 4" standpipe installed in accordance with nfpa 14. Date: July 3, 2017 Contractor: Dc Mechanical Dcm Permit type: Suppression permit | Permit status: Completed | Completion date: September 6, 2017 | Permit id: 793524 | |||||
SCORE 100 Install 600amp,1ph main service,install meter module. Install all wiring throughout per 2008 nec (mixed use)install fire alarm per nfpa 72 Date: August 18, 2017 Contractor: Baldwin Electrical Const Llc Permit type: Electrical permit | Permit status: Completed | Completion date: September 7, 2017 | Permit id: 790204 |