Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Administrative permit Date: June 4, 2014 Permit status: Completed | Permit id: 518994 | |||||
Addition permit Date: July 30, 2015 Permit status: Active | Permit id: 604464 | |||||
Electrical permit Date: March 4, 2016 Permit status: Expired | Permit id: 657607 | |||||
Zoning use permit Date: June 3, 2014 Permit status: Completed | Permit id: 538665 | |||||
Mechanical permit Date: November 20, 2015 Permit status: Completed | Permit id: 653475 | |||||
Electrical permit Date: February 11, 2013 Permit status: Completed | Permit id: 452978 | |||||
Plumbing permit Date: November 17, 2015 Permit status: Active | Permit id: 649119 | |||||
Administrative permit Date: December 1, 2016 Permit status: Completed | Permit id: 740230 | |||||
Administrative permit Date: February 4, 2010 Permit status: Completed | Permit id: 226975 | |||||
Suppression permit Date: March 1, 2016 Permit status: Completed | Permit id: 657447 | |||||
Demolition permit Date: May 20, 2015 Permit status: Completed | Permit id: 589005 | |||||
Zoning permit Date: May 20, 2015 Permit status: Completed | Permit id: 588998 | |||||
Zoning permit Date: May 2, 2014 Permit status: Completed | Permit id: 526729 | |||||
Electrical permit Date: August 24, 2009 Permit status: Expired | Permit id: 232968 | |||||
Permit for the partial demolition of existing one story structures and for the erection of a 4th story addition on top of an existing three (3) story structure for roof deck access w new common roof deck on forth (4th) floor and for the erection of decks and balconies from 2nd thru 04th floors for use as a twenty-three (23) family dwelling. Date: December 20, 2011 Applicant: David G. Orphanides, Esquire | Permit type: Appeal | Permit status: Continued | Permit id: 16887 | |||||
Permit for relocation of lot lines to create two (2) lots (lot 1 & 2) from three (3) lots. For the relocation of a common easement between 756-58 s. 16th st and 1607-19 catharine st. Lot 1 - for the partial demolition of rear three two one story portion of an existing three story detached structure. For the erection of five (5) six (6) story addition with green roof and elevator shaft (74 h) and roof deck with 42" high railing to the rear and for the erection of a partial 4th and 5th story addition above the three (3) story structure and proposed common roof deck above the existing three story portion and proposed twenty-three (23) accessory parking spaces including ten (10) interior parking spaces and one (1) h c space, ten (10) bicycle stalls and proposed one (1) accessory office and one (1) accessory gym and proposed thirty (31) dwelling units. For the erection of 4 high metal fence and 6 high metal fence completely within the property line, lot 2- ten (10) rooming units in an exi Date: January 23, 2013 Applicant: David G. Orphanides, Esq. | Permit type: Appeal | Permit status: Continued | Permit id: 19736 | |||||
SCORE 100 Pa# 2015-3030014 new construction for a new (3)story addition with roof decks for use as (29)res units with an incidental office space - flat offset of soil waste stacks (p2-1) must comply with section p-1107 and vent piping extending to the deck level must comply with section p-1103. 4. 1 of the philadelphia plumbing code 2004 - installation will comply with the approved plans and the philadelphia plumbing code 2004 Date: November 17, 2015 Contractor: Ferko Plumbing Permit type: Plumbing permit | Permit status: Completed | Completion date: June 28, 2017 | Permit id: 649119 | |||||
Duplicate c. O. And l. O. Date: February 4, 2010 Permit type: Administrative permit | Permit status: Completed | Completion date: February 17, 2010 | Permit id: 226975 | |||||
SCORE 100 Install 2 exit emergency lights as per 2005 nec (south district) Date: August 24, 2009 Contractor: Amptron Corp Permit type: Electrical permit | Permit status: Expired | Completion date: August 24, 2009 | Permit id: 232968 | |||||
SCORE 100 1 amp temporary service, (6) receptacles, temporary lights- not running wires. This permit expires in days ... In accordance with 2008 nec Date: February 11, 2013 Contractor: Radon Leszek Permit type: Electrical permit | Permit status: Completed | Completion date: April 14, 2014 | Permit id: 452978 | |||||
Preliminary plan review. Date: June 4, 2014 Permit type: Administrative permit | Permit status: Completed | Completion date: June 4, 2014 | Permit id: 518994 | |||||
For the relocation of lot lines to create (1) lot from (3) lots. The use change to (29) total residential units, for the erection of a rear (3) story additions with cellar as per plans Date: May 2, 2014 Permit type: Zoning permit | Permit status: Completed | Completion date: May 23, 2014 | Permit id: 526729 | |||||
Tco for units - a, b, c, 1a, 1b, 1c, 2a, 2b, 2c, 2h, 2i, 3a, 3c, and 3i. Date: December 1, 2016 Permit type: Administrative permit | Permit status: Completed | Completion date: December 9, 2016 | Permit id: 740230 | |||||
SCORE 89 Installing new wiring throughout the building,new outlets,sws,gfcis lights fixtures and new 1600amp 200v 3 phase service per 2008 nec (multi family)install new fire alarm per nfpa 72 Date: March 4, 2016 Contractor: Green Team Electric Inc Permit type: Electrical permit | Permit status: Completed | Completion date: February 28, 2017 | Permit id: 657607 | |||||
SCORE 89 Install (1) mini split system (mixed use) Date: November 20, 2015 Contractor: Alkaun Co Permit type: Mechanical permit | Permit status: Completed | Completion date: March 14, 2016 | Permit id: 653475 | |||||
SCORE 100 For the installation of a nfpa 13 fire supression system for a multi-family dwelling serviced by a 2 inch fire service line with a back flow preventer assembly and fire pump. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Fire suppression system to be installed in accordance with nfpa 13. Date: March 1, 2016 Contractor: Shannon Fire Protection Permit type: Suppression permit | Permit status: Completed | Completion date: December 15, 2016 | Permit id: 657447 | |||||
SCORE 89 Install (31) hvac systems with ductwork (mixed use) no penetrations between fire walls Date: November 20, 2015 Contractor: Alkaun Co Permit type: Mechanical permit | Permit status: Completed | Completion date: July 19, 2017 | Permit id: 653468 | |||||
For the erection of a new three (3) story rear addition with basement, roof decks, roof deck access stairs and new elevator extending to all floor levels; for a complete change of occupancy and interior alterations throughout the existing three (3) story structure to create a total of twenty-nine (29) new dwelling units (all type b incl. One type a) throughout the existing building and addition per plans. All special inspection reports shall be furnished to field inspector. Separate permits required for all fire suppression, mechanical, electrical and plumbing systems. Pa state department of labor and industry approval required for elevators lifting devices. Maintain protection of adjacent structures, r-o-w and pedestrians during construction. Date: July 30, 2015 Permit type: Addition permit | Permit status: Completed | Completion date: February 28, 2017 | Permit id: 604464 | |||||
For the erection of a rear (3) story additions with cellar for a 29 residential units. Date: June 3, 2014 Permit type: Zoning/use permit | Permit status: Completed | Completion date: June 3, 2014 | Permit id: 538665 | |||||
SCORE 96 Int demo (non-load bearing interior) Date: January 13, 2015 Contractor: James Dibartolo Permit type: Demolition permit | Permit status: Completed | Completion date: March 27, 2015 | Permit id: 584236 | |||||
For the partial demolition of an existing structure (rear gymnasium portion). Existing semi-detached front portion, fire tower and catwalk structure to remain. Size and location as shown on plans application. Date: May 20, 2015 Permit type: Zoning permit | Permit status: Completed | Completion date: May 20, 2015 | Permit id: 588998 | |||||
SCORE 96 Partial demolition of existing structure (rear gymnasium portion). Existing semi-detached front portion, fire tower and catwalk balcony structure to remain. Demolition to be conducted by hand within the safety zone and using hand controlled equipment for the remainder of the structure (see engineers report dated 1 28 15). All demolition to be conducted in a horizontal manner. Demolition in accordance with department code bulletin b-1302. Demolition of pool to comply with department code bulletin b-0403. Protection of pedestrians to be maintained during all demolition activities. Newly exposed exterior wall to be treated. Date: May 20, 2015 Contractor: James Dibartolo Permit type: Demolition permit | Permit status: Completed | Completion date: November 4, 2015 | Permit id: 589005 |