Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Plumbing permit Date: June 27, 2014 Permit status: Completed | Permit id: 540962 | |||||
Mechanical permit Date: June 19, 2014 Permit status: Completed | Permit id: 537978 | |||||
Electrical permit Date: August 14, 2014 Permit status: Expired | Permit id: 540799 | |||||
Plumbing permit Date: April 15, 2015 Permit status: Completed | Permit id: 576995 | |||||
Electrical permit Date: March 3, 2015 Permit status: Completed | Permit id: 570571 | |||||
Mechanical permit Date: December 31, 2015 Permit status: Completed | Permit id: 658720 | |||||
Zoning/use permit Date: December 16, 2013 Client: Huang Hui Qiu He Shu-Hua | Permit status: Completed | Permit id: 509059 | |||||
Administrative permit Date: August 20, 2014 Permit status: Completed | Permit id: 525159 | |||||
Use permit Date: August 4, 2014 Permit status: Completed | Permit id: 553437 | |||||
New construction permit Date: November 18, 2014 Permit status: Completed | Permit id: 569430 | |||||
Suppression permit Date: April 11, 2014 Permit status: Completed | Permit id: 517262 | |||||
Suppression permit Date: March 18, 2015 Permit status: Completed | Permit id: 596719 | |||||
Suppression permit Date: January 4, 2016 Permit status: Completed | Permit id: 661337 | |||||
Plumbing permit Date: July 31, 2014 Permit status: Completed | Permit id: 552856 | |||||
New construction permit Date: November 18, 2014 Permit status: Completed | Permit id: 569430 | |||||
Administrative permit Date: August 20, 2014 Permit status: Completed | Permit id: 525159 | |||||
Mechanical permit Date: June 19, 2014 Permit status: Completed | Permit id: 537978 | |||||
Mechanical permit Date: March 2, 2015 Permit status: Completed | Permit id: 570502 | |||||
Plumbing permit Date: April 15, 2015 Permit status: Completed | Permit id: 576995 | |||||
Electrical permit Date: August 14, 2014 Permit status: Expired | Permit id: 540799 | |||||
Suppression permit Date: April 11, 2014 Permit status: Completed | Permit id: 517262 | |||||
Electrical permit Date: March 3, 2015 Permit status: Completed | Permit id: 570571 | |||||
Zoning use permit Date: December 16, 2013 Client: Huang Hui Qiu He Shu-Hua | Permit status: Completed | Permit id: 509059 | |||||
Suppression permit Date: March 18, 2015 Permit status: Completed | Permit id: 596719 | |||||
Use permit Date: August 4, 2014 Permit status: Completed | Permit id: 553437 | |||||
Suppression permit Date: January 4, 2016 Permit status: Completed | Permit id: 661337 | |||||
SCORE 100 Nstallation of one (1) 12 ft, ul 7 listed commercial kitchen exhaust hood with a rated shaft for exhaust and make up air ductwork as per approved plans. Separate permit required for hood extinguishing system. Date: March 12, 2015 Contractor: Active Contracting Llc Permit type: Mechanical permit | Permit status: Completed | Completion date: May 5, 2015 | Permit id: 593162 | |||||
Installation of new hvac system for restaurant tenant on first floor to include installation of one (1) ul 7 listed commercial kitchen exhaust hood with tie in to exhaust and make up air fans and installation of one (1) rated shaft for exhaust and make up air ductwork as per approved plans. Fire dampers required at all floor ceiling penetrations not protected by shaft separate permit required for hood extinguishing system. Date: March 2, 2015 Permit type: Mechanical permit | Permit status: Completed | Completion date: May 5, 2015 | Permit id: 570502 | |||||
SCORE 100 Install 100amp, 120 280v panel 3 single phase 4w, install wiring throughout restaurant, all wiring mc cable type as per nec 2008 no fire alarm on this permit (mixed use) north dist) Date: March 3, 2015 Contractor: Baldwin Electrical Const Llc Permit type: Electrical permit | Permit status: Completed | Completion date: April 28, 2015 | Permit id: 570571 | |||||
Fitout of vacant ground floor commercial space to create a restaurant [group b - < occupants] as per approved plans. Constructed building is fully sprinklered. Separate permits required for any mep or fire suppression work Date: November 18, 2014 Permit type: New construction permit | Permit status: Completed | Completion date: May 6, 2015 | Permit id: 569430 | |||||
SCORE 100 Interior plumbing alterations on the basement and 1st floor for a new restaurant - fixtures equipment will be protected against backlfow by a method listed in table 608. 1 of the international plumbing code 2009 - all work will comply with the approved plans and the philadelphia plumbing code 2004 Date: April 15, 2015 Contractor: Superior Build Maintenance Permit type: Plumbing permit | Permit status: Completed | Completion date: May 6, 2015 | Permit id: 576995 | |||||
SCORE 100 Installation of new hvac system, ducts, mechanical equipment, dryers and vents, piping, firestop, furnaces, as per design engineered plans and schedule. Date: June 19, 2014 Contractor: Above And Below Heating And Air Permit type: Mechanical permit | Permit status: Completed | Completion date: August 19, 2014 | Permit id: 537978 | |||||
SCORE 96 12 apt units with new service and fa system provide egress,emergency and exit lighting and fa for vacant commercial space on the 1st floor per 2008 nec & nfpa 72 (mixed use) Date: August 14, 2014 Contractor: Jb Richards Construction Llc Permit type: Electrical permit | Permit status: Expired | Completion date: August 14, 2014 | Permit id: 540799 | |||||
SCORE 100 New construction - install 17 bathroom groups, 12 kitchens, 12 laundry rooms, 12 water heaters, 2" water service and 5" sewer and curb trap with fresh air inlet - pa1 call# Date: June 27, 2014 Contractor: J S Plumbing Company Llc Permit type: Plumbing permit | Permit status: Completed | Completion date: August 19, 2014 | Permit id: 540962 | |||||
SCORE 100 Water distribution,house trap Date: July 31, 2014 Contractor: Superior Build Maintenance Permit type: Plumbing permit | Permit status: Completed | Completion date: August 19, 2014 | Permit id: 552856 | |||||
Use to restaurant in first floor. Date: August 4, 2014 Permit type: Use permit | Permit status: Completed | Completion date: August 4, 2014 | Permit id: 553437 | |||||
SCORE 100 For the installation of an automatic fire suppression system throughout a mixed-use structure in accordance with nfpa 13 & 13r standards. System to be provided via a 4" fire service main line & is equipped with a backflow prevention assembly. Date: April 11, 2014 Contractor: Legacy Fire Sprinkler Services Permit type: Suppression permit | Permit status: Completed | Completion date: August 11, 2014 | Permit id: 517262 | |||||
Install one (1) 22 ft commercial kitchen hood system as per plan. Separate permit required for fss. Date: December 31, 2015 Permit type: Mechanical permit | Permit status: Completed | Completion date: February 9, 2016 | Permit id: 658720 | |||||
SCORE 86 Install 1-6 gallon pyro chem ul 3 fire system. Ez standard kitchen fire suppression- for the installation of new wet chemical kitchen hood fire suppression system as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: January 4, 2016 Contractor: J And S Fire Protection Inc Permit type: Suppression permit | Permit status: Completed | Completion date: February 9, 2016 | Permit id: 661337 | |||||
To amend building permit #514402, as built revisions and revisions as indicated. Additional excavation and site special inspection to be performed by registered engineer as per attached letter and provided to inspector, no special precautions or underpinning cited per engineer letter . Vacant commercial 1st floor requires use & co permits. Building fully sprinklered. Additional permits req: electrical, plumbing, hvac, sprinklers, co & use permit for vacant commercial & signs. No demolition of structures permitted approved on this permit, if existing. Date: August 20, 2014 Permit type: Administrative permit | Permit status: Completed | Completion date: August 21, 2014 | Permit id: 525159 | |||||
SCORE 100 Ez standard kitchen fire suppression- for the installation of new wet chemical kitchen hood fire suppression system as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: March 18, 2015 Contractor: East Coast Business Fire Inc Permit type: Suppression permit | Permit status: Completed | Completion date: May 5, 2015 | Permit id: 596719 | |||||
New construction of a 4 story structure, roof deck, civil site work. Additional excavation and site special inspection to be performed by registered engineer as per attached letter and provided to inspector, no special precautions or underpinning cited per engineer letter . Vacant commercial 1st floor requires use & co permits. Building fully sprinklered. Additional permits req: electrical, plumbing, hvac, sprinklers, co & use permit for vacant commercial & signs. No demolition of structures permitted approved on this permit, if existing. Date: March 13, 2014 Permit type: New construction permit | Permit status: Completed | Completion date: August 19, 2014 | Permit id: 514402 | |||||
For the erection of an attached structure (maximum height 42 ft 7 inches), with a deck on fourth floor front, for use as vacant commercial space on first floor front , for twelve(12) dwelling units on first floor rear thru fourth floor on lot a, Date: December 16, 2013 Permit type: Zoning/use permit | Permit status: Completed | Completion date: December 16, 2013 | Permit id: 509059 |