Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Capstone - block 1 - retaining wall - construction of permanent retaining wall on north side of property. Date: November 3, 2015 Value: $245,000 Applicant: Jason Lamb | Permit type: Retaining wall | Permit id: Bldg-2015-07607 | Parcel: 673100020 | |||||
Capstone-block 1- mixed use hotel with below-grade parking - underground plumbing for 5 garage drains and 3 sprinkler standpipes drains. The piping will be run back to an oil/water separator. Then the water will run to a storm water ejection basin. There will be 2 discharge pipes from the basin sun to the above ground. The permit is only for the below ground work at this time. Date: November 30, 2015 Value: $121,234 Applicant: Amy Hightower | Permit type: Plumbing - otc | Permit id: Plum-2015-09040 | Parcel: 673100020 | |||||
Sopa capstone-block 1- redmond hotel 425-268-2013 new 600a 480v temp service with 1 - 250a feeder to a crane and 3 - 1 feeders each to a 75kva transformer feeding a 200a panel. 2 of the panels to serve as power for construction spider boxes and 1 to feed construction trailers customer paid for:(1) temporary service/ (1) ground ufer - per inspector visit Date: December 7, 2015 Value: $30,000 Applicant: Daniel Dimascio | Permit type: Electrical - otc | Permit id: Elec-2015-09182 | Parcel: 673100020 | |||||
Capstone-block 1- mixed use hotel with below-grade parking using ibc 5 special provisions and wa state amendments requiring stair pressurization. Structure includes 2 levels below grade and 1-story above grade type i-a construction podium building with a 3-hour lid/ and a 5-story type v-a hotel above for a total of 6-stories above grade/ and 2 levels below grade. Type i-a building: 2-levels below grade: 75/376 sq ft s-2 parking garage and 2/046 sq ft b-occ office area; with 1-story above grade of separated uses : 2/466 st ft m occupancy; 7/5 sq ft a-2 occupancy; 16/879 sq ft a-3 occupancy; 2/896 sq ft b-occupancy; 4/311 sq ft r-1 occupancy; 5/816 sq ft of s-2 occupancy for a total of 117/3 sq ft structure. Type v-a building: the 5-story structure has two fire walls per ibc 706 to create 3 fire-flow areas. Separated uses: 3/944 sq ft a-3 occupancy/ 137/9 sq ft r-1 occupancy and 4/681 sq ft s-2 occupancy; 5/952 sq ft courtyard landscape space; for a total of 152/ Date: December 9, 2015 Value: $33,839,272 Applicant: Andy Paroline | Permit type: Mixed use | Permit id: Bldg-2015-03934 | Parcel: 673100020 | |||||
Capstone-block 1 - installation of complete drain/ waste/ vent/ domestic water/ and rain drains for new construction. Customer paid for (3) backflow preventers/ (18) bathtubs/ (3) clothes washer/ (122) dishwashers/ (4) drinking fountains/ (4) electric water heaters/ (83) floor drains/ (1) grease interceptor/ (14) hose bibs/ (23) roof drains/ (260) showers/ (311) bathroom sinks/ (28) floor sinks/ (125) kitchen sinks/ (311) toilets/ (7) urinals/ (122) ice maker connections. Total 1439 fixtures. Date: August 16, 2016 Value: $3,200,000 Applicant: Amy Hightower | Permit type: Plumbing plan review | Permit id: Plum-2016-05427 | Parcel: 673100020 | |||||
Capstone - block 1 - supply and install a 300kva 480v diesel generator with 12hr sub base tank. Wiring to generator panel/ 4 transfer switches/ and associated distribution equipment. Fuel port and exhaust by others Date: March 8, 2016 Value: $135,000 Applicant: Daniel Dimascio | Permit type: Electrical plan review | Permit id: Elec-2016-01550 | Parcel: 673100020 | |||||
Capstone-block 1- mixed use hotel with below-grade parking - pacific coast energy - 253-666-5535 - providing (2) 10 gallon propane tanks for heating at construction site. Otc approved by jim hill. Date: September 14, 2016 Applicant: Corey Mason | Permit type: Fire installation | Permit id: Fire-2016-07754 | Parcel: 673100020 | |||||
Reinstatement of elec-2016-015 - capstone - block 1 - supply and install a 300kva 480v diesel generator with 12hr sub base tank. Wiring to generator panel/ 4 transfer switches/ and associated distribution equipment. Fuel port and exhaust by others Date: September 21, 2016 Value: $135,000 Applicant: Daniel Dimascio | Permit type: Electrical plan review | Permit id: Elec-2016-07735 | Parcel: 673100020 | |||||
Sopa - capstone-block 1- starwood hotel - 425-527-1723 - install low voltage cabling for voice/ data/ video & security for new 7 story hotel. Powercom job #450956. Customer paid for:(564) low voltage Date: September 20, 2016 Value: $275,000 Applicant: Karin Rinaldi | Permit type: Electrical - otc | Permit id: Elec-2016-07891 | Parcel: 673100020 | |||||
Capstone-block 1- mixed use hotel with below-grade parking using ibc 5 special provisions and wa state amendments requiring stair pressurization. Structure includes 2 levels below grade and 1-story above grade type i-a construction podium building with a 3-hour lid/ and a 5-story type v-a hotel above for a total of 6-stories above grade/ and 2 levels below grade. Type i-a building: 2-levels below grade: 75/376 sq ft s-2 parking garage and 2/046 sq ft b-occ office area; with 1-story above grade of separated uses : 2/466 st ft m occupancy; 7/5 sq ft a-2 occupancy; 16/879 sq ft a-3 occupancy; 2/896 sq ft b-occupancy; 4/311 sq ft r-1 occupancy; 5/816 sq ft of s-2 occupancy for a total of 117/3 sq ft structure. Type v-a building: the 5-story structure has two fire walls per ibc 706 to create 3 fire-flow areas. Separated uses: 3/944 sq ft a-3 occupancy/ 137/9 sq ft r-1 occupancy and 4/681 sq ft s-2 occupancy; 5/952 sq ft courtyard landscape space; for a total of 152/ Date: July 13, 2016 Permit type: Side sewer | Permit id: Swr-2016-04459 | Parcel: 673100020 | |||||
Capstone-block 1- redmond hotel - install 2 new dry systems for new parking areas/ one new wet system for new amenities and hotel guest rooms/ one new standpipe system to supply standpipes to four new stairwells/ and one new fire pump to supply all new systems. Total 2/403 heads/ 1 riser/supply/ 1 pump/ 1 standpipe. Date: May 23, 2016 Value: $33,839,272 Applicant: Dave Fox | Permit type: Fire sprinkler - commercial | Permit id: Fire-2016-02473 | Parcel: 673100020 | |||||
Additional side sewer off ne shen street Date: June 10, 2016 Applicant: Nick Belanger | Permit type: Side sewer | Permit id: Swr-2016-04461 | Parcel: 673100020 | |||||
Capstone - block 1- mixed use hotel - wire new 281 unit hotel with 2 levels of underground parking and amenity space. Provide provisions for future retail. Service size is 3000a with associated feeders and panels to feed equipment. Date: January 20, 2016 Value: $33,839,272 Applicant: Daniel Dimascio | Permit type: Electrical - otc | Permit id: Elec-2016-00492 | Parcel: 673100020 | |||||
Capstone-block 1 - redmond hotel - fire systems west is installing a new fire alarm system/ complete electrical for fire alarm system. 253-951-6005 Date: August 4, 2016 Value: $150,000 Applicant: Matthew Carlman | Permit type: Electrical - otc | Permit id: Elec-2016-06635 | Parcel: 673100020 | |||||
Otc- capstone-block 1- installation of wiring for low voltage 8 mhz das system. Wiring only. Separate fire install permit needed for emergency radio. Date: November 22, 2016 Value: $13,822 Applicant: Spencer Tyler | Permit type: Electrical - otc | Permit id: Elec-2016-09439 | Parcel: 673100020 | |||||
Capstone-block 1- mixed use hotel with below-grade parking using ibc 5 special provisions and wa state amendments requiring stair pressurization. Structure includes 2 levels below grade and 1-story above grade type i-a construction podium building with a 3-hour lid/ and a 5-story type v-a hotel above for a total of 6-stories above grade/ and 2 levels below grade. Type i-a building: 2-levels below grade: 75/376 sq ft s-2 parking garage and 2/046 sq ft b-occ office area; with 1-story above grade of separated uses : 2/466 st ft m occupancy; 7/5 sq ft a-2 occupancy; 16/879 sq ft a-3 occupancy; 2/896 sq ft b-occupancy; 4/311 sq ft r-1 occupancy; 5/816 sq ft of s-2 occupancy for a total of 117/3 sq ft structure. Type v-a building: the 5-story structure has two fire walls per ibc 706 to create 3 fire-flow areas. Separated uses: 3/944 sq ft a-3 occupancy/ 137/9 sq ft r-1 occupancy and 4/681 sq ft s-2 occupancy; 5/952 sq ft courtyard landscape space; for a total of 152/ Date: July 13, 2016 Permit type: Water meter | Permit id: Wtr-2016-04458 | Parcel: 673100020 | |||||
Redmond hotel/capstone-block 1- mixed use hotel: installation of entire hvac system Date: October 17, 2016 Value: $2,409,960 Applicant: Amy Hightower | Permit type: Mechanical plan review | Permit id: Mech-2016-07985 | Parcel: 673100020 | |||||
Plumbing- redmond hotel/capstone estera hotel- grease interceptor- grease waste permit/ rest of job is already permitted on plum-2016-05427. Date: November 23, 2016 Value: $4,500 Applicant: Frank Granston | Permit type: Plumbing plan review | Permit id: Plum-2016-09343 | Parcel: 673100020 | |||||
SCORE 98 Capstone - block 1 - retaining wall - construction of permanent retaining wall on north side of property. Applicant: Jason Lamb | Permit type: Retaining wall | Permit id: Bldg-2015-07607 | Parcel: 673100020 | |||||
SCORE 95 Sopa capstone-block 1- redmond hotel 425-268-2013 new 600a 480v temp service with 1 - 250a feeder to a crane and 3 - 1 feeders each to a 75kva transformer feeding a 200a panel. 2 of the panels to serve as power for construction spider boxes and 1 to feed construction trailers customer paid for:(1) temporary service (1) ground ufer - per inspector visit Applicant: Daniel Dimascio | Permit type: Electrical - otc | Permit id: Elec-2015-09182 | Parcel: 673100020 | |||||
SCORE 98 Capstone-block 1- mixed use hotel with below-grade parking using ibc 5 special provisions and wa state amendments requiring stair pressurization. Structure includes 2 levels below grade and 1-story above grade type i-a construction podium building with a 3-hour lid and a 5-story type v-a hotel above for a total of 6-stories above grade and 2 levels below grade. Type i-a building: 2-levels below grade: 75 376 sq ft s-2 parking garage and 2 046 sq ft b-occ office area; with 1-story above grade of separated uses : 2 466 st ft m occupancy; 7 5 sq ft a-2 occupancy; 16 879 sq ft a-3 occupancy; 2 896 sq ft b-occupancy; 4 311 sq ft r-1 occupancy; 5 816 sq ft of s-2 occupancy for a total of 117 3 sq ft structure. Type v-a building: the 5-story structure has two fire walls per ibc 706 to create 3 fire-flow areas. Separated uses: 3 944 sq ft a-3 occupancy 137 9 sq ft r-1 occupancy and 4 681 sq ft s-2 occupancy; 5 952 sq ft courtyard landscape space; for a total of 152 Applicant: Andy Paroline | Permit type: Mixed use | Permit id: Bldg-2015-03934 | Parcel: 673100020 | |||||
SCORE 95 Capstone - block 1- mixed use hotel - wire new 281 unit hotel with 2 levels of underground parking and amenity space. Provide provisions for future retail. Service size is 3000a with associated feeders and panels to feed equipment. Applicant: Daniel Dimascio | Permit type: Electrical - otc | Permit id: Elec-2016-00492 | Parcel: 673100020 | |||||
SCORE 95 Capstone - block 1 - supply and install a 300kva 480v diesel generator with 12hr sub base tank. Wiring to generator panel 4 transfer switches and associated distribution equipment. Fuel port and exhaust by others Applicant: Daniel Dimascio | Permit type: Electrical plan review | Permit id: Elec-2016-01550 | Parcel: 673100020 | |||||
SCORE 95 Capstone-block 1 - redmond hotel - fire systems west is installing a new fire alarm system complete electrical for fire alarm system. 253-951-6005 Applicant: Matthew Carlman | Permit type: Electrical - otc | Permit id: Elec-2016-06635 | Parcel: 673100020 | |||||
SCORE 98 Sopa - capstone-block 1- starwood hotel - 425-527-1723 - install low voltage cabling for voice data video & security for new 7 story hotel. Powercom job #450956. Customer paid for:(564) low voltage Applicant: Karin Rinaldi | Permit type: Electrical - otc | Permit id: Elec-2016-07891 | Parcel: 673100020 | |||||
SCORE 95 Reinstatement of elec-2016-015 - capstone - block 1 - supply and install a 300kva 480v diesel generator with 12hr sub base tank. Wiring to generator panel 4 transfer switches and associated distribution equipment. Fuel port and exhaust by others Applicant: Daniel Dimascio | Permit type: Electrical plan review | Permit id: Elec-2016-07735 | Parcel: 673100020 | |||||
SCORE 86 Otc- capstone-block 1- installation of wiring for low voltage 8 mhz das system. Wiring only. Separate fire install permit needed for emergency radio. Applicant: Spencer Tyler | Permit type: Electrical - otc | Permit id: Elec-2016-09439 | Parcel: 673100020 | |||||
SCORE 92 Capstone-block 1- redmond hotel - install 2 new dry systems for new parking areas one new wet system for new amenities and hotel guest rooms one new standpipe system to supply standpipes to four new stairwells and one new fire pump to supply all new systems. Total 2 403 heads 1 riser supply 1 pump 1 standpipe. Applicant: Dave Fox | Permit type: Fire sprinkler - commercial | Permit id: Fire-2016-02473 | Parcel: 673100020 | |||||
SCORE 67 Capstone-block 1- mixed use hotel with below-grade parking - pacific coast energy - 253-666-5535 - providing (2) 10 gallon propane tanks for heating at construction site. Otc approved by jim hill. Date: September 14, 2016 Contractor: Pacific Coast Energy Applicant: Corey Mason | Permit type: Fire installation | Permit id: Fire-2016-07754 | Parcel: 673100020 | |||||
SCORE 89 Capstone-block 1- mixed use hotel with below-grade parking - underground plumbing for 5 garage drains and 3 sprinkler standpipes drains. The piping will be run back to an oil water separator. Then the water will run to a storm water ejection basin. There will be 2 discharge pipes from the basin sun to the above ground. The permit is only for the below ground work at this time. Applicant: Amy Hightower | Permit type: Plumbing - otc | Permit id: Plum-2015-09040 | Parcel: 673100020 | |||||
SCORE 100 Additional side sewer off ne shen street Date: June 10, 2016 Contractor: Hos Bros Construction Inc Applicant: Nick Belanger | Permit type: Side sewer | Permit id: Swr-2016-04461 | Parcel: 673100020 | |||||
SCORE 100 Capstone-block 1- mixed use hotel with below-grade parking using ibc 5 special provisions and wa state amendments requiring stair pressurization. Structure includes 2 levels below grade and 1-story above grade type i-a construction podium building with a 3-hour lid and a 5-story type v-a hotel above for a total of 6-stories above grade and 2 levels below grade. Type i-a building: 2-levels below grade: 75 376 sq ft s-2 parking garage and 2 046 sq ft b-occ office area; with 1-story above grade of separated uses : 2 466 st ft m occupancy; 7 5 sq ft a-2 occupancy; 16 879 sq ft a-3 occupancy; 2 896 sq ft b-occupancy; 4 311 sq ft r-1 occupancy; 5 816 sq ft of s-2 occupancy for a total of 117 3 sq ft structure. Type v-a building: the 5-story structure has two fire walls per ibc 706 to create 3 fire-flow areas. Separated uses: 3 944 sq ft a-3 occupancy 137 9 sq ft r-1 occupancy and 4 681 sq ft s-2 occupancy; 5 952 sq ft courtyard landscape space; for a total of 152 Date: July 13, 2016 Contractor: Hos Bros Construction Inc Permit type: Side sewer | Permit id: Swr-2016-04459 | Parcel: 673100020 | |||||
Capstone-block 1- mixed use hotel with below-grade parking using ibc 5 special provisions and wa state amendments requiring stair pressurization. Structure includes 2 levels below grade and 1-story above grade type i-a construction podium building with a 3-hour lid and a 5-story type v-a hotel above for a total of 6-stories above grade and 2 levels below grade. Type i-a building: 2-levels below grade: 75 376 sq ft s-2 parking garage and 2 046 sq ft b-occ office area; with 1-story above grade of separated uses : 2 466 st ft m occupancy; 7 5 sq ft a-2 occupancy; 16 879 sq ft a-3 occupancy; 2 896 sq ft b-occupancy; 4 311 sq ft r-1 occupancy; 5 816 sq ft of s-2 occupancy for a total of 117 3 sq ft structure. Type v-a building: the 5-story structure has two fire walls per ibc 706 to create 3 fire-flow areas. Separated uses: 3 944 sq ft a-3 occupancy 137 9 sq ft r-1 occupancy and 4 681 sq ft s-2 occupancy; 5 952 sq ft courtyard landscape space; for a total of 152 Date: July 13, 2016 Permit type: Water meter | Permit id: Wtr-2016-04458 | Parcel: 673100020 | |||||
SCORE 89 Capstone-block 1 - installation of complete drain waste vent domestic water and rain drains for new construction. Customer paid for (3) backflow preventers (18) bathtubs (3) clothes washer (122) dishwashers (4) drinking fountains (4) electric water heaters (83) floor drains (1) grease interceptor (14) hose bibs (23) roof drains (260) showers (311) bathroom sinks (28) floor sinks (125) kitchen sinks (311) toilets (7) urinals (122) ice maker connections. Total 1439 fixtures. Applicant: Amy Hightower | Permit type: Plumbing plan review | Permit id: Plum-2016-05427 | Parcel: 673100020 | |||||
SCORE 89 Redmond hotel capstone-block 1- mixed use hotel: installation of entire hvac system Applicant: Amy Hightower | Permit type: Mechanical plan review | Permit id: Mech-2016-07985 | Parcel: 673100020 | |||||
SCORE 89 Plumbing- redmond hotel capstone estera hotel- grease interceptor- grease waste permit rest of job is already permitted on plum-2016-05427. Applicant: Frank Granston | Permit type: Plumbing plan review | Permit id: Plum-2016-09343 | Parcel: 673100020 | |||||
Intercept existing wave conduit containing 864 count fiber and over set new wave 444la vault. Pull slack to new vault from existing wave vault located north near the round-a-bout at 152nd 36th and 157th. Coil and splice new fiber cable. Trench east to site property line and place new nb2436 vault. Pull new fiber cable through. Date: December 1, 2016 Applicant: Permits Mgc Technical | Permit type: Right of way | Permit id: Row-2016-09334 | Parcel: 673100020 | |||||
SCORE 100 Sopa - capstone esterra hotel block 1 - aloft element signage - 206-623-7676 - manufacture and install exterior signage. Customer paid for (6) wall signs (1) monument sign (1) blade sign (2) brackets. Applicant: Kelly Garrett | Permit type: Sign | Permit id: Sign-2016-09551 | Parcel: 673100020 | |||||
SCORE 98 Capstone - block 1 - retaining wall - construction of permanent retaining wall on north side of property. Applicant: Jason Lamb | Permit type: Retaining wall | Permit id: Bldg-2015-07607 | |||||
SCORE 89 Capstone-block 1- mixed use hotel with below-grade parking - underground plumbing for 5 garage drains and 3 sprinkler standpipes drains. The piping will be run back to an oil water separator. Then the water will run to a storm water ejection basin. There will be 2 discharge pipes from the basin sun to the above ground. The permit is only for the below ground work at this time. Applicant: Amy Hightower | Permit type: Plumbing - otc | Permit id: Plum-2015-09040 | |||||
SCORE 95 Sopa capstone-block 1- redmond hotel 425-268-2013 new 600a 480v temp service with 1 - 250a feeder to a crane and 3 - 1 feeders each to a 75kva transformer feeding a 200a panel. 2 of the panels to serve as power for construction spider boxes and 1 to feed construction trailers customer paid for:(1) temporary service (1) ground ufer - per inspector visit Applicant: Daniel Dimascio | Permit type: Electrical - otc | Permit id: Elec-2015-09182 | |||||
SCORE 98 Capstone-block 1- mixed use hotel with below-grade parking using ibc 5 special provisions and wa state amendments requiring stair pressurization. Structure includes 2 levels below grade and 1-story above grade type i-a construction podium building with a 3-hour lid and a 5-story type v-a hotel above for a total of 6-stories above grade and 2 levels below grade. Type i-a building: 2-levels below grade: 75 376 sq ft s-2 parking garage and 2 046 sq ft b-occ office area; with 1-story above grade of separated uses : 2 466 st ft m occupancy; 7 5 sq ft a-2 occupancy; 16 879 sq ft a-3 occupancy; 2 896 sq ft b-occupancy; 4 311 sq ft r-1 occupancy; 5 816 sq ft of s-2 occupancy for a total of 117 3 sq ft structure. Type v-a building: the 5-story structure has two fire walls per ibc 706 to create 3 fire-flow areas. Separated uses: 3 944 sq ft a-3 occupancy 137 9 sq ft r-1 occupancy and 4 681 sq ft s-2 occupancy; 5 952 sq ft courtyard landscape space; for a total of 152 Applicant: Andy Paroline | Permit type: Mixed use | Permit id: Bldg-2015-03934 | |||||
SCORE 95 Capstone - block 1- mixed use hotel - wire new 281 unit hotel with 2 levels of underground parking and amenity space. Provide provisions for future retail. Service size is 3000a with associated feeders and panels to feed equipment. Applicant: Daniel Dimascio | Permit type: Electrical - otc | Permit id: Elec-2016-00492 | |||||
SCORE 95 Capstone - block 1 - supply and install a 300kva 480v diesel generator with 12hr sub base tank. Wiring to generator panel 4 transfer switches and associated distribution equipment. Fuel port and exhaust by others Applicant: Daniel Dimascio | Permit type: Electrical plan review | Permit id: Elec-2016-01550 | |||||
SCORE 92 Capstone-block 1- redmond hotel - install 2 new dry systems for new parking areas one new wet system for new amenities and hotel guest rooms one new standpipe system to supply standpipes to four new stairwells and one new fire pump to supply all new systems. Total 2 403 heads 1 riser supply 1 pump 1 standpipe. Applicant: Dave Fox | Permit type: Fire sprinkler - commercial | Permit id: Fire-2016-02473 | |||||
SCORE 100 Additional side sewer off ne shen street Date: June 10, 2016 Contractor: Hos Bros Construction Inc Applicant: Nick Belanger | Permit type: Side sewer | Permit id: Swr-2016-04461 | |||||
SCORE 100 Capstone-block 1- mixed use hotel with below-grade parking using ibc 5 special provisions and wa state amendments requiring stair pressurization. Structure includes 2 levels below grade and 1-story above grade type i-a construction podium building with a 3-hour lid and a 5-story type v-a hotel above for a total of 6-stories above grade and 2 levels below grade. Type i-a building: 2-levels below grade: 75 376 sq ft s-2 parking garage and 2 046 sq ft b-occ office area; with 1-story above grade of separated uses : 2 466 st ft m occupancy; 7 5 sq ft a-2 occupancy; 16 879 sq ft a-3 occupancy; 2 896 sq ft b-occupancy; 4 311 sq ft r-1 occupancy; 5 816 sq ft of s-2 occupancy for a total of 117 3 sq ft structure. Type v-a building: the 5-story structure has two fire walls per ibc 706 to create 3 fire-flow areas. Separated uses: 3 944 sq ft a-3 occupancy 137 9 sq ft r-1 occupancy and 4 681 sq ft s-2 occupancy; 5 952 sq ft courtyard landscape space; for a total of 152 Date: July 13, 2016 Contractor: Hos Bros Construction Inc Permit type: Side sewer | Permit id: Swr-2016-04459 | |||||
SCORE 95 Capstone-block 1 - redmond hotel - fire systems west is installing a new fire alarm system complete electrical for fire alarm system. 253-951-6005 Applicant: Matthew Carlman | Permit type: Electrical - otc | Permit id: Elec-2016-06635 | |||||
SCORE 89 Capstone-block 1 - installation of complete drain waste vent domestic water and rain drains for new construction. Customer paid for (3) backflow preventers (18) bathtubs (3) clothes washer (122) dishwashers (4) drinking fountains (4) electric water heaters (83) floor drains (1) grease interceptor (14) hose bibs (23) roof drains (260) showers (311) bathroom sinks (28) floor sinks (125) kitchen sinks (311) toilets (7) urinals (122) ice maker connections. Total 1439 fixtures. Applicant: Amy Hightower | Permit type: Plumbing plan review | Permit id: Plum-2016-05427 | |||||
SCORE 67 Capstone-block 1- mixed use hotel with below-grade parking - pacific coast energy - 253-666-5535 - providing (2) 10 gallon propane tanks for heating at construction site. Otc approved by jim hill. Date: September 14, 2016 Contractor: Pacific Coast Energy Applicant: Corey Mason | Permit type: Fire installation | Permit id: Fire-2016-07754 | |||||
SCORE 98 Sopa - capstone-block 1- starwood hotel - 425-527-1723 - install low voltage cabling for voice data video & security for new 7 story hotel. Powercom job #450956. Customer paid for:(564) low voltage Applicant: Karin Rinaldi | Permit type: Electrical - otc | Permit id: Elec-2016-07891 | |||||
SCORE 95 Reinstatement of elec-2016-015 - capstone - block 1 - supply and install a 300kva 480v diesel generator with 12hr sub base tank. Wiring to generator panel 4 transfer switches and associated distribution equipment. Fuel port and exhaust by others Applicant: Daniel Dimascio | Permit type: Electrical plan review | Permit id: Elec-2016-07735 | |||||
SCORE 89 Redmond hotel capstone-block 1- mixed use hotel: installation of entire hvac system Applicant: Amy Hightower | Permit type: Mechanical plan review | Permit id: Mech-2016-07985 | |||||
SCORE 89 Plumbing- redmond hotel capstone estera hotel- grease interceptor- grease waste permit rest of job is already permitted on plum-2016-05427. Applicant: Frank Granston | Permit type: Plumbing plan review | Permit id: Plum-2016-09343 | |||||
SCORE 86 Otc- capstone-block 1- installation of wiring for low voltage 8 mhz das system. Wiring only. Separate fire install permit needed for emergency radio. Applicant: Spencer Tyler | Permit type: Electrical - otc | Permit id: Elec-2016-09439 | |||||
SCORE 100 Sopa - capstone esterra hotel block 1 - aloft element signage - 206-623-7676 - manufacture and install exterior signage. Customer paid for (6) wall signs (1) monument sign (1) blade sign (2) brackets. Applicant: Kelly Garrett | Permit type: Sign | Permit id: Sign-2016-09551 | |||||
SCORE 86 Capstone-block 1- installation of an 8 mhz emergency responder radio coverage distributed antenna system. Customer applied for (1) err system. Date: March 29, 2017 Contractor: Vti Electric Inc Applicant: Spencer Tyler | Permit type: Fire installation | Permit id: Fire-2017-01844 | |||||
SCORE 59 Capstone-block 1- mixed use hotel - kitchen hood fixed extinguishing system - 18 devices. Date: March 8, 2017 Contractor: Sanderson Fire Protection Inc Applicant: Dave Carlsen | Permit type: Fire fixed suppression | Permit id: Fire-2017-01543 | |||||
SCORE 89 Capstone-block 1- mixed use hotel - customer paid for (12) added backflow preventors Applicant: Amy Hightower | Permit type: Plumbing - otc | Permit id: Plum-2017-02744 | |||||
SCORE 98 Capstone-block 1- mixed use hotel with below-grade parking using ibc 5 special provisions and wa state amendments requiring stair pressurization. Structure includes 2 levels below grade and 1-story above grade type i-a construction podium building with a 3-hour lid and a 5-story type v-a hotel above for a total of 6-stories above grade and 2 levels below grade. Type i-a building: 2-levels below grade: 75 376 sq ft s-2 parking garage and 2 046 sq ft b-occ office area; with 1-story above grade of separated uses : 2 466 st ft m occupancy; 7 5 sq ft a-2 occupancy; 16 879 sq ft a-3 occupancy; 2 896 sq ft b-occupancy; 4 311 sq ft r-1 occupancy; 5 816 sq ft of s-2 occupancy for a total of 117 3 sq ft structure. Type v-a building: the 5-story structure has two fire walls per ibc 706 to create 3 fire-flow areas. Separated uses: 3 944 sq ft a-3 occupancy 137 9 sq ft r-1 occupancy and 4 681 sq ft s-2 occupancy; 5 952 sq ft courtyard landscape space; for a total of 152 Date: May 1, 2017 Contractor: Absher Construction Co Applicant: Nick Belanger | Permit type: Fire installation | Permit id: Fire-2017-01419 | |||||
SCORE 98 Capstone-block 1- places of assembly permit level 3 Date: May 17, 2017 Contractor: Absher Construction Co Applicant: Kevin Brattain | Permit type: Fire installation | Permit id: Fire-2017-01631 | |||||
SCORE 67 Sopa - capstone-block 1- floor 2 425-774-66 - meeting room av systems customer paid for:(1) low voltage Applicant: Dan Crabtree | Permit type: Electrical - otc | Permit id: Elec-2017-01544 | |||||
SCORE 98 Capstone-block 1- esterra park - redmond hotel - run raceways for (8) cameras. Customer paid for (8) low voltage. Applicant: Mike Doyle | Permit type: Electrical - otc | Permit id: Elec-2017-04671 | Parcel: 673100020 | |||||
SCORE 98 New permit to replace bldg-2015-07607 which expired on 03 13 2017 due to lack of inspections. Capstone - block 1 - retaining wall - construction of permanent retaining wall on north side of property. Applicant: Nick Belanger | Permit type: Retaining wall | Permit id: Bldg-2017-04175 | Parcel: 673100020 | |||||
SCORE 67 Sopa - capstone-block 1- floor 2 425-774-66 - meeting room av systems customer paid for:(1) low voltage Applicant: Dan Crabtree | Permit type: Electrical - otc | Permit id: Elec-2017-01544 | Parcel: 673100020 | |||||
SCORE 59 Sopa#47273 - csm redmond hotel - generator test - 253-395-9077 - performing a 1 hour load bank test of emergency standby generator. Customer paid for:(1) temporary service. Applicant: Kacy Trojcak | Permit type: Electrical - otc | Permit id: Elec-2017-02319 | Parcel: 673100020 | |||||
SCORE 100 Sopa#47259 - aloft redmond - 803-554-2943 - low voltage sound system customer paid for:(1) low voltage Applicant: William Higgins | Permit type: Electrical - otc | Permit id: Elec-2017-02307 | Parcel: 673100020 | |||||
SCORE 98 Capstone-block 1 - redmond hotel - installation of new fire alarm system for redmond hotel. Total 1 transmitter 1 control panel 12 power supplies 769 total devices. 253-833-1248 Date: January 23, 2017 Contractor: Fire Systems West Applicant: Matthew Carlman | Permit type: Fire alarm | Permit id: Fire-2016-06636 | Parcel: 673100020 | |||||
SCORE 98 Capstone - block 1 - aloft element hotel - interior emergency diesel generator - 555 gallon ul142 dual wall sub-base fuel tanke for storage of #2 diesel. Date: March 8, 2017 Contractor: Absher Construction Co Applicant: Kevin Brattain | Permit type: Fire installation | Permit id: Fire-2017-01234 | Parcel: 673100020 | |||||
SCORE 86 Capstone-block 1- installation of an 8 mhz emergency responder radio coverage distributed antenna system. Customer applied for (1) err system. Date: March 29, 2017 Contractor: Vti Electric Inc Applicant: Spencer Tyler | Permit type: Fire installation | Permit id: Fire-2017-01844 | Parcel: 673100020 | |||||
SCORE 59 Capstone-block 1- mixed use hotel - kitchen hood fixed extinguishing system - 18 devices. Date: March 8, 2017 Contractor: Sanderson Fire Protection Inc Applicant: Dave Carlsen | Permit type: Fire fixed suppression | Permit id: Fire-2017-01543 | Parcel: 673100020 | |||||
SCORE 98 Capstone-block 1- mixed use hotel with below-grade parking using ibc 5 special provisions and wa state amendments requiring stair pressurization. Structure includes 2 levels below grade and 1-story above grade type i-a construction podium building with a 3-hour lid and a 5-story type v-a hotel above for a total of 6-stories above grade and 2 levels below grade. Type i-a building: 2-levels below grade: 75 376 sq ft s-2 parking garage and 2 046 sq ft b-occ office area; with 1-story above grade of separated uses : 2 466 st ft m occupancy; 7 5 sq ft a-2 occupancy; 16 879 sq ft a-3 occupancy; 2 896 sq ft b-occupancy; 4 311 sq ft r-1 occupancy; 5 816 sq ft of s-2 occupancy for a total of 117 3 sq ft structure. Type v-a building: the 5-story structure has two fire walls per ibc 706 to create 3 fire-flow areas. Separated uses: 3 944 sq ft a-3 occupancy 137 9 sq ft r-1 occupancy and 4 681 sq ft s-2 occupancy; 5 952 sq ft courtyard landscape space; for a total of 152 Date: May 1, 2017 Contractor: Absher Construction Co Applicant: Nick Belanger | Permit type: Fire installation | Permit id: Fire-2017-01419 | Parcel: 673100020 | |||||
SCORE 98 Capstone-block 1- places of assembly permit level 3 Date: May 17, 2017 Contractor: Absher Construction Co Applicant: Kevin Brattain | Permit type: Fire installation | Permit id: Fire-2017-01631 | Parcel: 673100020 | |||||
1-1 2in exempt irrigation meter set downsteam from the 3in domestic meter Date: October 31, 2017 Applicant: Scott Peterson | Permit type: Water meter | Permit id: Wtr-2017-03718 | Parcel: 673100020 | |||||
SCORE 98 Capstone-block 1 - redmond hotel - installation of new fire alarm system for redmond hotel. Total 1 transmitter 1 control panel 12 power supplies 769 total devices. 253-833-1248 Date: January 23, 2017 Contractor: Fire Systems West Applicant: Matthew Carlman | Permit type: Fire alarm | Permit id: Fire-2016-06636 | |||||
SCORE 98 Capstone - block 1 - aloft element hotel - interior emergency diesel generator - 555 gallon ul142 dual wall sub-base fuel tanke for storage of #2 diesel. Date: March 8, 2017 Contractor: Absher Construction Co Applicant: Kevin Brattain | Permit type: Fire installation | Permit id: Fire-2017-01234 | |||||
SCORE 100 Sopa#47259 - aloft redmond - 803-554-2943 - low voltage sound system customer paid for:(1) low voltage Applicant: William Higgins | Permit type: Electrical - otc | Permit id: Elec-2017-02307 | |||||
SCORE 98 New permit to replace bldg-2015-07607 which expired on 03 13 2017 due to lack of inspections. Capstone - block 1 - retaining wall - construction of permanent retaining wall on north side of property. Applicant: Nick Belanger | Permit type: Retaining wall | Permit id: Bldg-2017-04175 | |||||
SCORE 98 Capstone-block 1- esterra park - redmond hotel - run raceways for (8) cameras. Customer paid for (8) low voltage. Applicant: Mike Doyle | Permit type: Electrical - otc | Permit id: Elec-2017-04671 | |||||
SCORE 89 Capstone-block 1- mixed use hotel - customer paid for (12) added backflow preventors Applicant: Amy Hightower | Permit type: Plumbing - otc | Permit id: Plum-2017-02744 | Parcel: 673100020 |