SCORE 100 For the complete demolition of an existing, attached, two (2) story structure. Structure to be demolished by hand and with hand tools only. Pedestrian protection to be in place prior to start of work and to be maintained during all demolition activities. A covered walkway or sidewalk closure shall be required within 7 feet of building facade in accordance with section 3306 of the ibc. Separate building and or streets department permits are required. See submitted plans for proposed closure. 21 day posting and notice required per a-303. 2 (5 15 2017 earliest start) newly exposed walls to be treated. Permit received from downstairs 5 15 17 Date: May 11, 2017 Contractor: Pedro Palmer Construction Inc Client: Ra Development Llc | Permit type: Demolition permit | Permit status: Completed | Completion date: June 7, 2017 | Permit id: 777348 | |||||
SCORE 100 Seal lateral pa20171020574 remove house trap and hermetically sealing the lateral by a cap or plug per section p-606. 1 of the philadelphia plumbing code 2004 - "self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" Date: April 12, 2017 Contractor: Shegda Construction Corp Client: Ra Development Llc | Permit type: Plumbing permit | Permit status: Expired | Completion date: April 12, 2017 | Permit id: 774785 | |||||
For the complete demolition of the existing structure. Lot to remain vacant, use registration permit required prior to use. Date: May 11, 2017 Client: Ra Development Llc | Permit type: Zoning/use permit | Permit status: Completed | Completion date: May 11, 2017 | Permit id: 777352 | |||||
SCORE 82 New construction of three story attached structure with cellar, roof deck, and access pilot house (for stairs and landing only) Date: June 1, 2017 Contractor: Frank Kumas Client: Ra Development Llc | Permit type: New construction permit | Permit status: Active | Completion date: September 13, 2017 | Permit id: 784054 | |||||
SCORE 100 For the installation of an automatic sprinkler system with a 1" combined fire & domestic service line for a three (3) story single family dwelling with rooftop structure. System installation in accordance with nfpa 13d. Date: July 26, 2017 Contractor: Oneida Fire Protection Client: Ra Development Llc | Permit type: Suppression permit | Permit status: Active | Completion date: September 6, 2017 | Permit id: 793486 | |||||
SCORE 79 Ez mech permit sfd: all equipment and associated duct work to be contained entirely within tenant space. No communicating ductwork. Gas fired appliances not to be located in ceiling space where used as a return air plenum. Returns to be ducted. Installation of mechanical equipment. All equipment and associated duct work is to be installed entirely within the same dwelling unit with no penetrations of fire rated assemblies and installed as per manufactures specifications. Installation must meet the code requirements of the international mechanical code and the international energy conservation code. Ductwork direct vent heater and a c Date: July 20, 2017 Contractor: Aspen Hvac Llc Client: Ra Development Llc | Permit type: Mechanical permit | Permit status: Active | Completion date: September 6, 2017 | Permit id: 801678 | |||||
SCORE 100 Install 3 toilets 3 lavs,3 tubs,1 kitchen,1 washer,5" lateral,1"water service,house trap,house trap and fresh air inlet-pa1#20172300013-"self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" Date: August 18, 2017 Contractor: Ferko Plumbing Client: Ra Development Llc | Permit type: Plumbing permit | Permit status: Completed | Completion date: September 21, 2017 | Permit id: 809771 | |||||
SCORE 100 Install 200amp service complete with meter panel & grounding 110v smokes, outlets, switches, lights, hihats, low voltage wiring for phone, cable tv & door bell as nec 2008 code (north district) Date: December 7, 2017 Contractor: Ade Electric Client: Ra Development Llc | Permit type: Electrical permit | Permit status: Active | Completion date: December 7, 2017 | Permit id: 837798 |