Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 65 Interior alterations to existing 27th and 28th floors penthouse as per plans Permit type: Permit - renovation/ | Permit id: 100091526 | |||||
SCORE 100 Upgrade existing 1200 amp building service to a new 2000 amp 3 phase, 4 wire service. All existing feeders to remain & be re-routed to new switchboard. Install 1 new 400 amp distribution panel for motor loads. Swbd. Drawing reqs. Re-submittal and review. R. Kus Permit type: Permit - electric wi | Permit id: 100095024 | |||||
SCORE 99 Rework existing 200amp service. Install new meter and panel for apartment #12s Permit type: Permit - electric wi | Permit id: 100099687 | |||||
SCORE 56 Erect 3 scaffolds to operate from 4 24 06 thru 4 24 07 Permit type: Permit - scaffolding | Permit id: 100107518 | |||||
SCORE 71 Replace plumbing fixtures only Date: August 23, 2006 Contractor: Pl15841 Hill Mechanical Corp Permit type: Permit - easy permit | Permit id: 100132862 | |||||
SCORE 59 Modernize the service elevator as per scope of work Permit type: Permit - elevator eq | Permit id: 100141526 | |||||
SCORE 90 Erect 1 tyrek modular scaffold from 10 09 2006 to 10 08 2007 for critical examination. Date: October 12, 2006 Contractor: Gilco Scaffolding Permit type: Permit - scaffolding | Permit id: 100142480 | |||||
SCORE 95 Interior demolition to non-load bearing partitions on the 17th and 18th floors as per plans(landmark) Permit type: Permit - renovation/ | Permit id: 100181047 | |||||
SCORE 65 Revision to permit #100091526. Interior and exterior renovation at 27th and 28th floors penthouse unit as per plans Permit type: Permit - renovation/ | Permit id: 100183015 | |||||
SCORE 64 Remodeling of existing co-op condominium unit 9s existing steam boiler heat Permit type: Permit - renovation/ | Permit id: 100196742 | |||||
SCORE 95 Install and terminate low voltage wiring in a duplex condo remodel. Low voltage systems include phone data, sound, video, lighting control, and security. Permit type: Permit - electric wi | Permit id: 100199907 | |||||
SCORE 95 Furnish and install all electrical work for penthouse residence. Job# 133-019 Permit type: Permit - electric wi | Permit id: 100205569 | |||||
SCORE 86 Erect 2 tyrek modular. For critical exam. From 10 24 07 to 10 23 07. Date: October 26, 2007 Contractor: Sbk Building Restoration Permit type: Permit - scaffolding | Permit id: 100208589 | |||||
SCORE 95 Interior alterations to unit 17s on floors 17 and 18 as per plan Permit type: Permit - renovation/ | Permit id: 100215598 | |||||
SCORE 56 Interior buildout of unit 5n including kitchen & baths Permit type: Permit - renovation/ | Permit id: 100223644 | |||||
SCORE 95 We have been chosen by bulley & andrews as the new electrical contractor of record replacing all phase electric. Please refer to the original building permit #100183015. Continental job# 133-019 Permit type: Permit - electric wi | Permit id: 100229430 | |||||
SCORE 98 Interior alterations to existing condo on 22nd floor. New exterior windows on all elevations. No hvac work. Permit type: Permit - renovation/ | Permit id: 100241980 | |||||
SCORE 56 Erect 1 standard basic step-type . For debris canopy from 6 23 08 to 6 23 09 Date: June 12, 2008 Contractor: Find Creative Enterpise Inc Permit type: Permit - scaffolding | Permit id: 100242501 | |||||
SCORE 99 Erect 7 spider modular swingstage from 8 7 08 to 8 7 09. Date: August 7, 2008 Contractor: Mark 1 Restoration Permit type: Permit - scaffolding | Permit id: 100251662 | |||||
SCORE 99 Grinding. Repair replace 50 pieces of limestone ashlars dutchman, repair replace northwest corner and outer wyeth 800 sq. Ft., tuckpoint limestone and brick 2000 sq. Ft., remove replace sealant 4000 linear ft., limestone patch 20 sq. Ft., replace lintels 150 linear ft (350 sq ft). All work on north and east elevations only, no structural work""- all work same as existing; subject to field inspections Permit type: Permit - easy permit | Permit id: 100252114 | |||||
SCORE 99 Interior alteration on the 17th and 18th floors of existing 27 story condominium building. Permit type: Permit - renovation/ | Permit id: 100263831 | |||||
SCORE 100 Erect two mast climber scaffolds from 03 09 2009 - 03 09 2010,no other repairs on this permit. Permit type: Permit - scaffolding | Permit id: 100280847 | |||||
SCORE 74 1st reinstatement of # 100223644 (interior buildout of unit 5n including kitchen & baths) Permit type: Permit - reinstate r | Permit id: 100297362 | |||||
SCORE 100 Replace 29 existing windows same size and type on 26th floor. Subject to field inspection Permit type: Permit - easy permit | Permit id: 100299359 | |||||
SCORE 99 Erect 7 spider modular swingstage scaffolds from 8 26 09 to 8 26 10. Date: August 26, 2009 Contractor: Mark 1 Restoration Permit type: Permit - scaffolding | Permit id: 100307760 | |||||
SCORE 67 1st reinstatement of permit (interior alterations to existing condo on 22nd floor. New exterior windows on all elevations. No hvac work.). All original contractors to remain Permit type: Permit - reinstate r | Permit id: 100318234 | |||||
SCORE 100 Replace (6) windows for apt 15 on east elevation- all work same as existing Permit type: Permit - easy permit | Permit id: 100426680 | |||||
SCORE 99 Remove old bx cable and wiremold outlets to 9 existing outlets. Replace with pipe. Replace 8 existing fixtures with new. Rework existing a c and install disconnect switch. General maintenance Permit type: Permit - electric wi | Permit id: 100454440 | |||||
SCORE 95 Remove & replace plaster, finishes, 8 plumbing fixtures, electrical permit # 100454448. Appliancesequipment and tile. Permit type: Permit - easy permit | Permit id: 100455790 | |||||
SCORE 99 Interior renovation of unit 7n in existing multi-unit residential building. Permit type: Permit - renovation/ | Permit id: 100475236 | |||||
SCORE 56 Erect 1 altrex modular platform pc-1 hoist from 5 9 2013 to 5 9 2014. Permit type: Permit - scaffolding | Permit id: 100489943 | |||||
SCORE 59 3rd reinstatement of permit # 100241980 for interior remodeling of full floor residential unit #2200 & change gc to chicago construction consultants Permit type: Permit - reinstate r | Permit id: 100504082 | |||||
SCORE 100 South elevation, repair replace 18 windows on the 13th floor for unit 135 only Permit type: Permit - easy permit | Permit id: 100504116 | |||||
SCORE 95 All elevations, tuckpoint 5100sf, repair replace 405lf flashing, repair replace 5100sf sealand, repair replace 250lf window sealant. No structural Permit type: Permit - easy permit | Permit id: 100514223 | |||||
SCORE 86 Relocate some receptacle in remodeled kitchen using existing circuits and ed 2 new circuits in apt. 6n Permit type: Permit - electric wi | Permit id: 100529290 | |||||
SCORE 95 Work to be done in unit 6n only: removereplace renovation bath & kitchen. Cabinet, countertops, plumbing fixtures, flooring, tile, drywall, 30 sheets, windows. Electrical permit # 100529290. Permit type: Permit - easy permit | Permit id: 100529394 | |||||
SCORE 100 Replace windows on the 24th floor (no structural work)- all work same as existing; subject to field inspections Permit type: Permit - easy permit | Permit id: 100532236 | |||||
SCORE 100 Revision to permit # 100535339 to change plumbing contractor to prospective plumbing corp & vent contractor to aa service Permit type: Permit - easy permit | Permit id: 100535339 | |||||
SCORE 95 Electrical contractor name change Permit type: Permit - electric wi | Permit id: 100535875 | |||||
SCORE 95 Replace existing 200amp pushmatic circuit breaker panel with a 200amp 40 circuit quick plug circuit breaker panel. Add circuit for washer and dryer. Value: $2,000 Contractor: True Power Electric Permit type: Permit - electric wi | Permit id: 100535893 | |||||
Install new 36""x 80"" door & non-loading bearing partial wall to close up opening between dining room & kitchen. Replace existing plumbing fixtures with associated piping. Replace existing china cabinets. Patch & close up wall. Replace existing drapery alcove. Subject to field inspections",17-03-111-005-0000,,,,,contractor-general contractor,"lakeside remodeling, inc. Date: April 25, 2014 Value: $40,000 Permit type: Permit - easy permit | Permit id: 100537699 | |||||
SCORE 94 Remodeling of existing kitchen, (2) bathrooms, powder room and 200 amp service Permit type: Permit - electric wi | Permit id: 100538858 | |||||
SCORE 95 Replace 14 windows for unit 6n. All work sae Permit type: Permit - easy permit | Permit id: 100540743 | |||||
SCORE 95 Removereplace 16 windows. All work same as existing. Permit type: Permit - easy permit | Permit id: 100542996 | |||||
SCORE 59 Erect 1 scaffold from 7 23 14 to 7 23 15 Permit type: Permit - scaffolding | Permit id: 100551735 | |||||
SCORE 100 Coax and cat6 wire to wall plates from distro to multiple locations. Working on unit 5 s. Value: $2,000 Contractor: High Tech Electrical Contracto Permit type: Permit - electric wi | Permit id: 100563142 | |||||
SCORE 95 Installation of new traveling cables on (4) passenger elevators. (ev003401) Permit type: Permit - elevator eq | Permit id: 100564589 | |||||
SCORE 100 Replacing existing exit signs in 5 areas with chicago-approved battery back up fixtures per city request. Permit type: Permit - electric wi | Permit id: 100575489 | |||||
SCORE 100 All elevations, tuckpoint 4015 sq. Ft., repairreplace flashing 235 ln. Ft., paint silane sealer 4015 sq. Ft., repairreplace window sealant 640 ln. Ft., only. Permit type: Permit - easy permit | Permit id: 100588902 | |||||
SCORE 73 Replace storm doors on balcony for unit 21. All work sae Permit type: Permit - easy permit | Permit id: 100588832 | |||||
SCORE 100 Replace 19 windows for unit 8s. All work sae Permit type: Permit - easy permit | Permit id: 100601496 | |||||
SCORE 95 Work to be done in unit 6n only: remove replace renovation bath & kitchen. Cabinet, countertops, plumbing fixtures, flooring, tile, drywall, sheets, windows. Electrical permit # 100529290. Permit type: Permit - easy permit process | Permit id: 100529394 | |||||
SCORE 73 Install new 36"x 80" door & non-loading bearing partial wall to close up opening between dining room & kitchen. Replace existing plumbing fixtures with associated piping. Replace existing china cabinets. Patch & close up wall. Replace existing drapery alcove. Subject to field inspections Permit type: Permit - easy permit process | Permit id: 100537699 | |||||
SCORE 67 1st reinstatement of permit (interior alterations to existing condo on 22nd floor. New exterior windows on all elevations. No hvac work.). All original contractors to remain Permit type: Permit - reinstate revoked pmt | Permit id: 100318234 | |||||
SCORE 95 Replace (6) windows for apt 15 on east elevation- all work same as existing Permit type: Permit - easy permit process | Permit id: 100426680 | |||||
SCORE 95 All elevations, tuckpoint 5100sf, repair replace 405lf flashing, repair replace 5100sf sealand, repair replace 250lf window sealant. No structural Permit type: Permit - easy permit process | Permit id: 100514223 | |||||
SCORE 59 3rd reinstatement of permit # 1002419 for interior remodeling of full floor residential unit #22 & change gc to chicago construction consultants Permit type: Permit - reinstate revoked pmt | Permit id: 100504082 | |||||
SCORE 100 Replacing existing exit signs in 5 areas with chicago-approved battery back up fixtures per city request. Permit type: Permit - electric wiring | Permit id: 100575489 | |||||
SCORE 99 Erect 7 spider modular swingstage from 8 7 08 to 8 7 09. Date: August 7, 2008 Contractor: Mark 1 Restoration Permit type: Permit - scaffolding | Permit id: 100251662 | |||||
SCORE 99 Erect 7 spider modular swingstage scaffolds from 8 26 09 to 8 26 10. Date: August 26, 2009 Contractor: Mark 1 Restoration Permit type: Permit - scaffolding | Permit id: 100307760 | |||||
SCORE 95 Remove & replace plaster, finishes, 8 plumbing fixtures, electrical permit # 100454448. Appliances equipment and tile. Permit type: Permit - easy permit process | Permit id: 100455790 | |||||
SCORE 95 Installation of new traveling cables on (4) passenger elevators. (ev003401) Permit type: Permit - elevator equipment | Permit id: 100564589 | |||||
SCORE 95 Replace windows on the 24th floor (no structural work)- all work same as existing; subject to field inspections Permit type: Permit - easy permit process | Permit id: 100532236 | |||||
SCORE 93 Relocate some receptacle in remodeled kitchen using existing circuits and ed 2 new circuits in apt. 6n Permit type: Permit - electric wiring | Permit id: 100529290 | |||||
SCORE 59 Erect 1 scaffold from 7 23 14 to 7 23 15 Permit type: Permit - scaffolding | Permit id: 100551735 | |||||
SCORE 95 Revision to permit # 100535339 to change plumbing contractor to prospective plumbing corp & vent contractor to aa service Permit type: Permit - easy permit process | Permit id: 100535339 | |||||
SCORE 94 Remodeling of existing kitchen, (2) bathrooms, powder room and 2 amp service Permit type: Permit - electric wiring | Permit id: 100538858 | |||||
SCORE 95 Furnish and install all electrical work for penthouse residence. Job# 133-019 Permit type: Permit - electric wiring | Permit id: 100205569 | |||||
SCORE 64 Remodeling of existing co-op condominium unit 9s existing steam boiler heat Permit type: Permit - renovation/alteration | Permit id: 100196742 | |||||
SCORE 99 Grinding. Repair replace pieces of limestone ashlars dutchman, repair replace northwest corner and outer wyeth 8 sq. Ft., tuckpoint limestone and brick 20 sq. Ft., remove replace sealant 40 linear ft., limestone patch sq. Ft., replace lintels 1 linear ft (3 sq ft). All work on north and east elevations only, no structural work"- all work same as existing; subject to field inspections Permit type: Permit - easy permit process | Permit id: 100252114 | |||||
SCORE 90 Erect 1 tyrek modular scaffold from 10 09 2006 to 10 08 2007 for critical examination. Date: October 12, 2006 Contractor: Gilco Scaffolding Permit type: Permit - scaffolding | Permit id: 100142480 | |||||
SCORE 71 Replace plumbing fixtures only Date: August 23, 2006 Contractor: Pl15841hill Mechanical Corp Permit type: Permit - easy permit process | Permit id: 100132862 | |||||
SCORE 100 Erect two mast climber scaffolds from 03 09 2009 - 03 09 2010,no other repairs on this permit. Permit type: Permit - scaffolding | Permit id: 100280847 | |||||
SCORE 95 Remove replace 16 windows. All work same as existing. Permit type: Permit - easy permit process | Permit id: 100542996 | |||||
SCORE 99 Rework existing 200amp service. Install new meter and panel for apartment #12s Permit type: Permit - electric wiring | Permit id: 100099687 | |||||
SCORE 95 Upgrade existing 12 amp building service to a new 20 amp 3 phase, 4 wire service. All existing feeders to remain & be re-routed to new switchboard. Install 1 new 4 amp distribution panel for motor loads. Swbd. Drawing reqs. Re-submittal and review. R. Kus Permit type: Permit - electric wiring | Permit id: 100095024 | |||||
SCORE 65 Interior alterations to existing 27th and 28th floors penthouse as per plans Permit type: Permit - renovation/alteration | Permit id: 100091526 | |||||
SCORE 95 Wiring upgrade for the kitchen in the appartment 4s. Permit type: Permit - electric wiring | Permit id: 100635949 | |||||
SCORE 95 All elevations, repair replace 3 stone dutchman, tuck-point 112 lineal ft., repair replace window perimeter sealant 49 lineal ft., only-subject to field inspections Permit type: Permit - easy permit process | Permit id: 100634591 | |||||
SCORE 56 Erect 1 scaffold from 2 9 16 to 2 9 17 Permit type: Permit - scaffolding | Permit id: 100634599 | |||||
SCORE 95 Replace 19 windows for unit 8s. All work sae Permit type: Permit - easy permit process | Permit id: 100601496 | |||||
SCORE 100 All elevations, tuckpoint 4015 sq. Ft., repair replace flashing 235 ln. Ft., paint silane sealer 4015 sq. Ft., repair replace window sealant 6 ln. Ft., only. Permit type: Permit - easy permit process | Permit id: 100588902 | |||||
SCORE 86 Erect 2 tyrek modular. For critical exam. From 10 24 07 to 10 23 07. Date: October 26, 2007 Contractor: Sbk Building Restoration Permit type: Permit - scaffolding | Permit id: 100208589 | |||||
SCORE 59 Modernize the service elevator as per scope of work Permit type: Permit - elevator equipment | Permit id: 100141526 | |||||
SCORE 73 Replace storm doors on balcony for unit 21. All work sae Permit type: Permit - easy permit process | Permit id: 100588832 | |||||
SCORE 83 1st reinstatement of # 100223644 (interior buildout of unit 5n including kitchen & baths) Permit type: Permit - reinstate revoked pmt | Permit id: 100297362 | |||||
SCORE 95 Electrical contractor name change Permit type: Permit - electric wiring | Permit id: 100535875 | |||||
SCORE 95 Replace 29 existing windows same size and type on 26th floor. Subject to field inspection Permit type: Permit - easy permit process | Permit id: 100299359 | |||||
SCORE 56 Erect 1 standard basic step-type . For debris canopy from 6 23 08 to 6 23 09 Date: June 12, 2008 Contractor: Find Creative Enterpise, Inc Permit type: Permit - scaffolding | Permit id: 100242501 | |||||
SCORE 95 Install and terminate low voltage wiring in a duplex condo remodel. Low voltage systems include phone data, sound, video, lighting control, and security. Permit type: Permit - electric wiring | Permit id: 100199907 | |||||
SCORE 95 Door installation for a 2nd entrance to an existing 12th floor residential unit 11n &12n Permit type: Permit - easy permit process | Permit id: 100640869 | |||||
SCORE 98 Interior alterations to existing condo on 22nd floor. New exterior windows on all elevations. No hvac work. Permit type: Permit - renovation/alteration | Permit id: 100241980 | |||||
SCORE 62 Remodel kitchen-no plumbing . Electrical on separate permit. Replace bay window with like in kind. Work in unit 4c Permit type: Permit - easy permit process | Permit id: 100637413 | |||||
SCORE 95 Replace 14 windows for unit 6n. All work sae Permit type: Permit - easy permit process | Permit id: 100540743 | |||||
SCORE 95 Remove old bx cable and wiremold outlets to 9 existing outlets. Replace with pipe. Replace 8 existing fixtures with new. Rework existing a c and install disconnect switch. General maintenance Permit type: Permit - electric wiring | Permit id: 100454440 | |||||
SCORE 95 South elevation, repair replace 18 windows on the 13th floor for unit 135 only Permit type: Permit - easy permit process | Permit id: 100504116 | |||||
SCORE 56 Partial renovation and combine 2 residential units 3n and 3s in existing residential masonry building as per plans. Permit type: Permit - renovation/alteration | Permit id: 100685219 | |||||
SCORE 95 We have been chosen by bulley & andrews as the new electrical contractor of record replacing ? All phase electric?. Please refer to the original building permit #100183015. Continental job# 133-019 Permit type: Permit - electric wiring | Permit id: 100229430 | |||||
SCORE 98 Interior renovations to existing 1 story residential unit #22 in existing 28 story type i-a construction, a2 occupancy building. Work includes electrical, plumbing, air conditioning and window replacement. Certified corrections- - subject to field inspections & audit Permit type: Permit - renovation/alteration | Permit id: 100690129 | |||||
SCORE 91 Install 6 tv outlets, 8 speakers, 22 control dimmers for units 3 n & 3 s Permit type: Permit - electric wiring | Permit id: 100727287 | |||||
SCORE 95 All elevations, tuckpoint 30 sq. Ft., repair replace flashing 3 lineal ft., repair replace brick 2 sq. Ft., repair replace all window and joint sealant 100%, only. Subject to field inspections. Permit type: Permit - easy permit process | Permit id: 100728841 | |||||
SCORE 95 Erect 1 scaffold from 10 2 17 to 10 2 18 Permit type: Permit - scaffolding | Permit id: 100728923 | |||||
SCORE 56 2nd reinstatement of permit # 100241980 for 50% of the original cost. All subs to remain. Permit type: Permit - reinstate revoked pmt | Permit id: 100375521 | |||||
SCORE 95 Replace existing 200amp pushmatic circuit breaker panel with a 200amp circuit quick plug circuit breaker panel. Add circuit for washer and dryer. Value: $2,000 Contractor: True Power Electric Permit type: Permit - electric wiring | Permit id: 100535893 | |||||
SCORE 95 Coax and cat6 wire to wall plates from distro to multiple locations. Working on unit 5 s. Value: $2,000 Contractor: Hightech Electrical Contracto Permit type: Permit - electric wiring | Permit id: 100563142 |