Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Suppression permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Active | Permit id: 655617 | |||||
Electrical permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Expired | Permit id: 549955 | |||||
Mechanical permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Completed | Permit id: 541994 | |||||
Alteration permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Active | Permit id: 604536 | |||||
Alteration permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Revoked | Permit id: 541131 | |||||
Use permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Completed | Permit id: 527885 | |||||
Plumbing permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Active | Permit id: 598011 | |||||
Permit a multi-family household living (3 units) in an existing three (3) story structure. ![]() Client: Criniti Anthony Criniti Theresa | Applicant: Landmark Architectural Design | Permit type: Appeal | Permit status: Granted | Completion date: September 10, 2014 | Permit id: 22830 | |||||
On 6/29/15, the department of licenses and inspections issued a notice of refusal for application #604536. ![]() Client: Criniti Anthony Criniti Theresa | Applicant: Vincent Mancini | Permit type: Appeal | Permit status: Approved | Completion date: October 13, 2015 | Permit id: 25683 | |||||
Alteration permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Completed | Permit id: 552555 | |||||
Plumbing permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Active | Permit id: 598011 | |||||
Alteration permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Active | Permit id: 604536 | |||||
Mechanical permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Completed | Permit id: 541994 | |||||
Electrical permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Expired | Permit id: 549955 | |||||
Use permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Completed | Permit id: 527885 | |||||
Suppression permit ![]() Client: Criniti Anthony Criniti Theresa | Permit status: Active | Permit id: 655617 | |||||
Permit a multi-family household living (3 units) in an existing three (3) story structure. ![]() Client: Criniti Anthony Criniti Theresa | Applicant: Landmark Architectural Design | Permit type: Appeal | Permit status: Granted | Completion date: September 10, 2014 | Permit id: 22830 | |||||
On 6 29 15, the department of licenses and inspections issued a notice of refusal for application #604536. ![]() Client: Criniti Anthony Criniti Theresa | Applicant: Vincent Mancini | Permit type: Appeal | Permit status: Approved | Completion date: October 13, 2015 | Permit id: 25683 | |||||
For a multi-family household living ![]() Client: Criniti Anthony Criniti Theresa | Permit type: Use permit | Permit status: Completed | Completion date: October 28, 2014 | Permit id: 527885 | |||||
SCORE 89 Interior alterations throughout, to include drywall throughout, moisture resistant drywall in the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Note: contractor is listed as a "sole proprietor" and has no employees and or workers compensation insurance - all subcontractors require separate licenses and insurance separate permits required for plumbing, electrical and mechanical work ![]() ![]() Client: Criniti Anthony Criniti Theresa | Permit type: Alteration permit | Permit status: Revoked | Completion date: November 27, 2015 | Permit id: 541131 | |||||
SCORE 100 Install 90% gas furnace in basement for 1st fl apartment with air and related duct ![]() ![]() Client: Criniti Anthony Criniti Theresa | Permit type: Mechanical permit | Permit status: Completed | Completion date: August 10, 2015 | Permit id: 541994 | |||||
SCORE 100 Rewire 1st floor to existing electrical panel, high hats,kitchen and bath (5 gfis) per 2008 nec (sfd) ![]() ![]() Client: Criniti Anthony Criniti Theresa | Permit type: Electrical permit | Permit status: Expired | Completion date: July 17, 2014 | Permit id: 549955 | |||||
Replace brick veneer on first floor front wall - work to be done in accordance with the ez permit standard for masonry veneers. Install 4 inch brick veneer on new concrete footing in front of existing masonry wall as per 2009 irc 703. 7. Maximum height: feet above foundation. Maximum thickness 5 inches. Window and door openings same size location and shall comply with emergency egress standard as per irc. New concrete footing to be below frost line, ( inches). New wall shall be anchored to supporting wall with corrosion-resistant metal ties 24 inches on center horizontally and vertically. Provide 1 inch air space between walls. Provide weep holes and flashing above window and door openings. Provide capping, flashing and caulking at termination of wall to prevent water infiltration. An inspection of existing wall to be scheduled with inspector before work starts. Work not to commence without inspectors approval. ![]() Client: Criniti Anthony Criniti Theresa | Permit type: Alteration permit | Permit status: Completed | Completion date: August 28, 2014 | Permit id: 552555 | |||||
SCORE 100 1st floor 2wc,2lav,1tub,1shower,1ks,1washer box and 3hot water heaters in the basement-the installation will comply with the philadelphia plumbing code 2004 ![]() ![]() Client: Criniti Anthony Criniti Theresa | Permit type: Plumbing permit | Permit status: Expired | Completion date: January 17, 2017 | Permit id: 598011 | |||||
For level ii alterations and for the legalization of interior renovations to convert an existing two family dwelling into a three family dwelling. Work required variance from the board of building standards, reference notes on plans for provisos recommended from the bbs. All work to be done per approved plans. If field conditions vary contact design professional prior to the start of any work. Separate permits required for mechanical, electrical, plumbing and fire suppression (nfpa 13r required) work. ![]() Client: Criniti Anthony Criniti Theresa | Permit type: Alteration permit | Permit status: Expired | Completion date: January 13, 2017 | Permit id: 604536 | |||||
SCORE 100 For the installation of an automatic fire suppression system throughout a multi-family residence in accordance with nfpa 13r standards. Systemt to be provided with a backflow prevention assembly and serviced via a 2" fire service main line. ![]() ![]() Client: Criniti Anthony Criniti Theresa | Permit type: Suppression permit | Permit status: Expired | Completion date: January 13, 2017 | Permit id: 655617 |