Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 59 North redmond elementary - plumbing for new 77 567 sq ft elementary school consisting of waste vent domestic water systems. Customer paid for (1) backflow preventer (1) clothes washer (4) drinking fountains (45) floor drains (12) hose bibs (1) shower valve replacement (15) bathroom sink (2) floor mop sinks (48) kitchen sinks (37) toilets (18) urinals (6) other fixtures to include steamer kettle emergency eye wash hose reel ware washer & serving station. (190) total fixtures. Applicant: Alan Taylor | Permit type: Plumbing plan review | Permit id: Plum-2017-05114 | Parcel: 2526059072 | |||||
SCORE 100 North redmond elementary - project includes the installation of a new hvac system including (74) vavs (71) heat pumps (6) roof hoods (painted to match roof) (43) fire dampers fire-smoke dampers (8) louvers (470) grds (1) sound attenuator (3) furnaces (4) dedicated outside air units (1) screened rooftop exhaust fan with new type 1 exhaust hood (47) ceiling fans (8) exhaust fans (5) unit heaters (1) boiler (2) gas water heaters (1) packaged hvac unit (8) condenser water pumps and (1) boiler circulation pump. Applicant: Ivy Levangie | Permit type: Mechanical plan review | Permit id: Mech-2017-04612 | Parcel: 2526059072 | |||||
SCORE 100 Vault - north redmond elementary school - south tank (#2) - pre-cast concrete stormwater detention vault - south tank (#2) - 2 l x 44 w x 8 t = ~77 4 cuft Applicant: Andrew Sahl | Permit type: Stormwater vault | Permit id: Bldg-2017-02101 | |||||
SCORE 100 Cnew- north redmond elementary - construction of a new 2-story elementary school of type ii-b sprinklered construction. The building is separated into five fire areas per the redmond fire code using an approved alternative non-prescriptive approach to ibc 706 fire walls. Included in the project area: 83 268 sf e-occupancy on 2 floors; 724 sf covered trash area; 12 571 sf for (4) mechanical equipment platforms located above the 2nd floor and under roof area; 1 458 sf canopies; 3 247 sf roof overhangs for a total of 101 268 sf. Applicant: Andrew Cottrill | Permit type: Commercial | Permit id: Bldg-2017-00143 | |||||
SCORE 59 North redmond elementary - plumbing for new 77 567 sq ft elementary school consisting of waste vent domestic water systems. Customer paid for (1) backflow preventer (1) clothes washer (4) drinking fountains (45) floor drains (12) hose bibs (1) shower valve replacement (15) bathroom sink (2) floor mop sinks (48) kitchen sinks (37) toilets (18) urinals (6) other fixtures to include steamer kettle emergency eye wash hose reel ware washer & serving station. (190) total fixtures. Applicant: Alan Taylor | Permit type: Plumbing plan review | Permit id: Plum-2017-05114 | |||||
SCORE 100 North redmond elementary - project includes the installation of a new hvac system including (74) vavs (71) heat pumps (6) roof hoods (painted to match roof) (43) fire dampers fire-smoke dampers (8) louvers (470) grds (1) sound attenuator (3) furnaces (4) dedicated outside air units (1) screened rooftop exhaust fan with new type 1 exhaust hood (47) ceiling fans (8) exhaust fans (5) unit heaters (1) boiler (2) gas water heaters (1) packaged hvac unit (8) condenser water pumps and (1) boiler circulation pump. Applicant: Ivy Levangie | Permit type: Mechanical plan review | Permit id: Mech-2017-04612 | |||||
SCORE 100 North redmond elementary - new 2-story elementary school of type ii-b sprinklered construction. Project includes new wet pipe fire sprinkler system with (2) riser supplies and (838) heads. ![]() ![]() Applicant: Andrew Moren | Permit type: Fire sprinkler - commercial | Permit id: Fire-2017-07290 | |||||
SCORE 100 Vault - north redmond elementary school - north tank (#1) - construction of a pre-cast concrete storm water detention vault - 176 l x 44 w x (15 t and t) = ~87 8 cuft Applicant: Andrew Sahl | Permit type: Stormwater vault | Permit id: Bldg-2017-02093 | |||||
SCORE 100 Vault - north redmond elementary school - north tank (#1) - construction of a pre-cast concrete storm water detention vault - 176 l x 44 w x (15 t and t) = ~87 8 cuft Applicant: Andrew Sahl | Permit type: Stormwater vault | Permit id: Bldg-2017-02093 | Parcel: 2526059045 | |||||
SCORE 100 Vault - north redmond elementary school - south tank (#2) - pre-cast concrete stormwater detention vault - south tank (#2) - 2 l x 44 w x 8 t = ~77 4 cuft Applicant: Andrew Sahl | Permit type: Stormwater vault | Permit id: Bldg-2017-02101 | Parcel: 2526059045 | |||||
SCORE 100 Cnew- north redmond elementary - construction of a new 2-story elementary school of type ii-b sprinklered construction. The building is separated into five fire areas per the redmond fire code using an approved alternative non-prescriptive approach to ibc 706 fire walls. Included in the project area: 83 268 sf e-occupancy on 2 floors; 724 sf covered trash area; 12 571 sf for (4) mechanical equipment platforms located above the 2nd floor and under roof area; 1 458 sf canopies; 3 247 sf roof overhangs for a total of 101 268 sf. Applicant: Andrew Cottrill | Permit type: Commercial | Permit id: Bldg-2017-00143 | Parcel: 2526059072 | |||||
SCORE 99 North redmond elementary -electrical installation for a new 2-story 77 567 sq ft elementary school of type iib construction fully sprinklered. Includes (27) feeders (350) fire alarm devices (1) generator (1) ground ufer (617) low voltage (1) service - new (30) sub panels and (1) temprorary service. Applicant: Jeffrey Nordberg | Permit type: Electrical plan review | Permit id: Elec-2017-04646 | Parcel: 2526059072 | |||||
SCORE 99 North redmond elementary -electrical installation for a new 2-story 77 567 sq ft elementary school of type iib construction fully sprinklered. Includes (27) feeders (350) fire alarm devices (1) generator (1) ground ufer (617) low voltage (1) service - new (30) sub panels and (1) temprorary service. Applicant: Jeffrey Nordberg | Permit type: Electrical plan review | Permit id: Elec-2017-04646 | |||||
SCORE 100 North redmond elementary - new 2-story elementary school of type ii-b sprinklered construction. Project includes new wet pipe fire sprinkler system with (2) riser supplies and (838) heads. ![]() ![]() Applicant: Andrew Moren | Permit type: Fire sprinkler - commercial | Permit id: Fire-2017-07290 | Parcel: 2526059072 |