Alteration permit ![]() Permit status: Completed | Permit id: 329660 | |||||
Suppression permit ![]() Permit status: Completed | Permit id: 480584 | |||||
Electrical permit ![]() Permit status: Expired | Permit id: 521798 | |||||
Plumbing permit ![]() Permit status: Completed | Permit id: 331979 | |||||
Suppression permit ![]() Permit status: Completed | Permit id: 431250 | |||||
Electrical permit ![]() Permit status: Completed | Permit id: 340625 | |||||
Operations permit ![]() Permit status: Completed | Permit id: 22917 | |||||
Operations permit ![]() Permit status: Completed | Permit id: 22221 | |||||
Zoning/use permit ![]() Permit status: Completed | Permit id: 361333 | |||||
New construction permit ![]() Permit status: Completed | Permit id: 332318 | |||||
Electrical permit ![]() Permit status: Completed | Permit id: 577250 | |||||
Suppression permit ![]() Permit status: Completed | Permit id: 343364 | |||||
Operations permit ![]() Permit status: Completed | Permit id: 23603 | |||||
Zoning/use permit ![]() Permit status: Completed | Permit id: 475251 | |||||
Suppression permit ![]() Permit status: Completed | Permit id: 528923 | |||||
Electrical permit ![]() Permit status: Completed | Permit id: 376027 | |||||
Mechanical permit ![]() Permit status: Completed | Permit id: 343469 | |||||
Addition permit ![]() Permit status: Completed | Permit id: 355676 | |||||
Administrative permit ![]() Permit status: Completed | Permit id: 369775 | |||||
Mechanical permit ![]() Permit status: Completed | Permit id: 477723 | |||||
Plumbing permit ![]() Permit status: Completed | Permit id: 635200 | |||||
Operations permit ![]() Permit status: Completed | Permit id: 22017 | |||||
Suppression permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 480584 | |||||
Zoning use permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 361333 | |||||
Operations permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 22917 | |||||
Electrical permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 362683 | |||||
Suppression permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 369318 | |||||
Mechanical permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 343469 | |||||
Electrical permit ![]() Client: Fleetpark Llc | Permit status: Expired | Permit id: 521798 | |||||
New construction permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 332318 | |||||
Alteration permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 329660 | |||||
Plumbing permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 331979 | |||||
Electrical permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 577250 | |||||
Mechanical permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 477723 | |||||
Electrical permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 376027 | |||||
Suppression permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 528923 | |||||
Operations permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 22017 | |||||
Administrative permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 369776 | |||||
Plumbing permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 635200 | |||||
Zoning use permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 475251 | |||||
Suppression permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 431250 | |||||
Operations permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 22221 | |||||
Operations permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 23603 | |||||
Addition permit ![]() Client: Fleetpark Llc | Permit status: Completed | Permit id: 355676 | |||||
SCORE 100 Alterations: interior plumbing; renovations to offices within warehouse space b-the installation will comply with the philadephia plubming code 2004 ![]() ![]() Permit type: Plumbing permit | Permit status: Active | Completion date: June 29, 2017 | Permit id: 768857 | |||||
SCORE 99 Amending permit#343469, to show structural support for ductwork, as per plans. ![]() ![]() Permit type: Administrative permit | Permit status: Completed | Completion date: June 1, 2012 | Permit id: 369775 | |||||
SCORE 100 Relocation of (9) sprinklers in warehouse ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: June 1, 2012 | Permit id: 362833 | |||||
SCORE 100 Relocate 8" fire sprinkler main ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: May 25, 2012 | Permit id: 369318 | |||||
SCORE 100 New feeder from existing panel 12 new mcc for waste water treatment system in existing space elcan room. Work including installation of additional lighting, fire detection system and wiring of new waste water treatment system as per 2008 nec ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: May 24, 2012 | Permit id: 362683 | |||||
SCORE 99 Install new smoke stack and ductwork. ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: May 1, 2012 | Permit id: 343469 | |||||
SCORE 100 For the erection a water treatment system as part of waste water treatment. Z u permit # 24033. ![]() ![]() Permit type: Addition permit | Permit status: Completed | Completion date: June 1, 2012 | Permit id: 355676 | |||||
SCORE 76 Installation of industrial exhaust ventilation system, roof venting, equipment installations, accessory mechanicals, ductwork, including structural modifications & support framing for new loading conditions equipment installations. ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: May 1, 2012 | Permit id: 361377 | |||||
SCORE 100 Installation of one (1) wall sign (non-illuminated) consisting of four sections to create a single face and attached with eight inch (8") lag and shield anchors per engineers design; installation of two (2), ground mounted free-standing signs with dual aluminum support posts embedded in 3,0 psi concrete footings. Separate permit required for any electrical work. ![]() ![]() Permit type: Sign permit | Permit status: Active | Completion date: June 14, 2017 | Permit id: 768435 | |||||
SCORE 100 Installing 2 sprinklers under a mezzanine and 1 sprinkler in an office on the main floor of allied tube. These areas an have existing overhead sprinkler system previously installed ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: November 23, 2012 | Permit id: 431250 | |||||
SCORE 100 Mechanical alterations to include the installation of 19 registers and diffuers, new exterior vent stacks & all fans, dampers, exhausts and ductwork to support proposed system. Special inspections are to be performed by a third-party as identified on such named form. ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: March 3, 2014 | Permit id: 477723 | |||||
SCORE 100 Improvements to nfpa 13 automatic sprinkler system serving industrial facility. Includes coverage in the industrial ventilation system. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: March 3, 2014 | Permit id: 480583 | |||||
SCORE 100 Installation of new mains,lines and 27 sprinklers in basement area to existing sprinkler system. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: March 3, 2014 | Permit id: 480584 | |||||
SCORE 95 Install new fire alarm system throughout bldg as per nec 2008 & nfpa 72 (comm) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: July 28, 2017 | Permit id: 521798 | |||||
SCORE 100 Install addressable modules for new sprinkler system & 2-new bathroom strobes as per nfpa 72 east district ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: September 7, 2017 | Permit id: 785569 | |||||
SCORE 86 Install 1 hvac unit with ductwork & 1 heat pump (commercial) ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: October 5, 2017 | Permit id: 762336 | |||||
SCORE 100 Removal and closure of one 3,5 gallon acid tank, all work will be conducted in accordance with state and federal regulations, a closure report wil be provieded upon copmoetion of the work. Report will include fluid disposal manifest and tank scrap receipt ![]() ![]() Permit type: Demolition permit | Permit status: Completed | Completion date: October 12, 2017 | Permit id: 767357 | |||||
SCORE 100 Install all power conduits for zinc pots, install power to 6 motors, install powe to warning lights (15) as per 2008 nec (east district) industrial plant ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: October 9, 2012 | Permit id: 376027 | |||||
SCORE 99 New 6" tie in install curb trap fresh air inlet and aproxiatmently 6 of drain into bldg from sanitary sewer for floor drain in bldg ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: January 27, 2012 | Permit id: 331979 | |||||
SCORE 100 Install new preaction detection system for 6-zinc pots per plans as per nec 2008 & nfpa 72 (manufacturing) see log ![]() ![]() Permit type: Electrical permit | Permit status: Expired | Completion date: May 1, 2014 | Permit id: 528859 | |||||
SCORE 100 Erect tent for company party tables and chairs (30x50) ![]() ![]() Permit type: Operations permit | Permit status: Completed | Permit id: 22017 | |||||
SCORE 68 Hotworks: welding cutting soldering torch work - permit expires 04 02 2014 ![]() ![]() Permit type: Operations permit | Permit status: Completed | Permit id: 22221 | |||||
SCORE 68 Hotworks: welding cutting soldering torch work - permit expires 05 29 2015 ![]() ![]() Permit type: Operations permit | Permit status: Completed | Permit id: 22917 | |||||
SCORE 100 Roof replacement (1 2 portion) single-ply (manufacturing & warehouse) - not more than 10% sheathing replacement ![]() ![]() Permit type: Alteration permit | Permit status: Completed | Completion date: August 10, 2011 | Permit id: 329651 | |||||
Amending bldg permit#361377, structural support loading revisions, as indicated per plans. ![]() Permit type: Administrative permit | Permit status: Completed | Completion date: June 1, 2012 | Permit id: 369776 | |||||
SCORE 76 1-600a 3 phase 4 volt feeder, power dpdc, 2 -100a 3 phase 4 volt feeder mua 2 & 3 as per 2008 nec (east district) warehouse ![]() ![]() Permit type: Electrical permit | Permit status: Expired | Completion date: November 29, 2011 | Permit id: 375345 | |||||
SCORE 100 Installation of new dry fire sprinkler system at 1988 addition of existing factory in accordance with the nfpa 13 standard and as per approved plans. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: August 21, 2017 | Permit id: 756816 | |||||
SCORE 92 Level ii alterations (no change of occupancy) for renovations to offices within warehouse space b as per approved plans. Existing building fully sprinklered. Separate permits required for mep & fire suppression work ![]() ![]() Permit type: Alteration permit | Permit status: Completed | Completion date: June 21, 2017 | Permit id: 759880 | |||||
SCORE 76 1-1 hp fan, 2 amp, 4 volt 3 phase, 1-. 5 hp filter motor, amp 4 volt, 3 phase, 1- hp fan, amp 4 volt, 3 phase, all as per 2008 nec (east dist) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: October 7, 2011 | Permit id: 340625 | |||||
SCORE 68 Hotworks: welding cutting soldering torch work - permit expires 07 01 2016 ![]() ![]() Permit type: Operations permit | Permit status: Completed | Permit id: 23603 | |||||
SCORE 100 Roof recovering (1 2 portion) single-ply (manufacturing & warehouse) - not more than 10% sheathing replacement - see hansen bp#329651 for roof replacement portion ![]() ![]() Permit type: Alteration permit | Permit status: Completed | Completion date: October 11, 2011 | Permit id: 329660 | |||||
SCORE 100 Relocate existing sprinkler heads (commercial) ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: April 25, 2017 | Permit id: 769377 | |||||
SCORE 89 Install(28) 2x4 drop-in lights,install (3)2x2 drop-in lights,9 switches,8 exit lights, duplex outlets,install 4 arc gfci,3 exhaust fans and 1 heavy duty disconnect switch per nfpa 72 (warehouse) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: May 19, 2017 | Permit id: 769643 | |||||
SCORE 100 Security system alarm sensors with 2- keypads with a dsc security panel in rear. Camera system, hd ip cameras with nvr unit in it closet- all low voltage cable (cat5): 7- cameras, 13 door contacts overhead, 4- door contacts, panel, 2 keypads... Per 2008 nec (warehouse) ![]() ![]() Permit type: Electrical permit | Permit status: Expired | Completion date: June 2, 2017 | Permit id: 774028 | |||||
SCORE 92 Replace existing mcc with new like in kind from original location. Transfer feed & 7 existing loads to new. Install approved junction box above existing mcc location. ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: August 20, 2016 | Permit id: 577250 | |||||
SCORE 95 Replace house trap and fai ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: September 1, 2015 | Permit id: 635200 | |||||
SCORE 100 Installation of 100amp service for air filtration system as per 2008 nec ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: July 29, 2011 | Permit id: 333916 | |||||
Install concrete foundations & equipment pads for mech equip. Separate permits (ductwork, and or zoning permit for a vent stack) required for installation of a blower stack & make-up air unit. ![]() Permit type: New construction permit | Permit status: Completed | Completion date: May 1, 2012 | Permit id: 332318 | |||||
SCORE 100 Installation of a sprinkler system into the existing exhaust ducts. Rough-in branch line are 1" thru 2" per plan and hyd. Cals. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: June 1, 2012 | Permit id: 343364 | |||||
SCORE 100 Installing 6 new 2 inch deluge valves, piping and sprinkler heads in the exhaust ducts at allied tube in accordance with nfpa 13. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: June 12, 2014 | Permit id: 528923 |