SCORE 95 Rewiring for rooftop ac units and installation of disconnect switch boxes. Reference cpl2017-00795. Client: Judith Bryant | Permit type: Electrical | Permit status: Cmp | Completion date: September 25, 2017 | Current use: Multifamily dwellings, existing | Permit id: Pmt2017-03788 | |||||
SCORE 95 Electrical - a c unit must be identified with unit number. A c unit must have a means of disconnect within sight of equipment (required on roof next to unit). All wiring must be ran in approved conduit. Exposed romex shall not be used between the wall and the a c unit. Electrician needs to verify that breakers in panels are sized correctly. A service receptacle must be installed for service work. No exterior changes proposed or approved. Reference cpl2017-00808. Client: Paul Goldan | Permit type: Electrical | Permit status: Cmp | Completion date: September 29, 2017 | Current use: Single family detached dwelling, existin | Permit id: Pmt2017-04129 |