Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Plumbing permit Date: February 23, 2016 Client: Pbh9 Llc | Permit status: Expired | Permit id: 671612 | |||||
Demolition permit Date: May 25, 2016 Client: Pbh9 Llc | Permit status: Completed | Permit id: 684636 | |||||
Zoning/use permit Date: August 18, 2016 Client: Pbh9 Llc | Permit status: Completed | Permit id: 695406 | |||||
Addition permit Date: August 18, 2016 Client: Pbh9 Llc | Permit status: Active | Permit id: 695418 | |||||
Plumbing permit Date: February 23, 2016 Client: Pbh9 Llc | Permit status: Expired | Permit id: 671612 | |||||
Addition permit Date: August 18, 2016 Client: Pbh9 Llc | Permit status: Active | Permit id: 695418 | |||||
Zoning use permit Date: August 18, 2016 Client: Pbh9 Llc | Permit status: Completed | Permit id: 695406 | |||||
Electrical permit Date: November 9, 2016 Client: Pbh9 Llc | Permit status: Active | Permit id: 733579 | |||||
Mechanical permit Date: October 18, 2016 Client: Pbh9 Llc | Permit status: Active | Permit id: 729869 | |||||
Demolition permit Date: May 25, 2016 Client: Pbh9 Llc | Permit status: Completed | Permit id: 684636 | |||||
SCORE 86 Re-wire of tr receptacles, switches, gfis, hard wired smoke and c o detectors, arc fault breakers, new service, ground and bond all equipment... Work per 2008 nec for a one family building Date: November 9, 2016 Contractor: Main Line Electrical Cont Llc Client: Pbh9 Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: November 9, 2016 | Permit id: 733579 | |||||
SCORE 70 Roughin only 5-lavs, 3-toilets, 2-tubs, 1-laundry standpipe, 1-kitchen sink, 2-hose bibs & pvc drains & pex manablok throughout the installation will comply with the philadelphia plumbing code 2004 Date: November 2, 2016 Contractor: William Bogsch Plumbing And Htg Client: Pbh9 Llc | Permit type: Plumbing permit | Permit status: Active | Completion date: September 27, 2017 | Permit id: 733978 | |||||
For the erection of a one story addition on the third floor level with a roof deck over the third story portion accessed by a spiral stairway from the third floor level to an existing two story attached structure. Structure for use as a single family dwelling. New foundations, new framing structure, new interior framing per attached plans. Building to be fully sprinklered. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Separate permits required for mechanical, electrical, plumbing and fire suppression work. Date: August 18, 2016 Client: Pbh9 Llc | Permit type: Addition permit | Permit status: Active | Completion date: October 18, 2017 | Permit id: 695418 | |||||
SCORE 86 Install 3. 5 ton a c unit with 80,0 btu gas furnace 92% with related duct work Date: October 18, 2016 Contractor: Desantis Mechanical Svcs Inc Client: Pbh9 Llc | Permit type: Mechanical permit | Permit status: Active | Completion date: September 27, 2017 | Permit id: 729869 | |||||
SCORE 100 For the installation of an automatic fire suppression system in accordance with nfpa 13d throughout three story townhouse to include new 1. 5-inch combined line as per approved plans. Date: March 27, 2017 Contractor: Legacy Fire Sprinkler Services Client: Pbh9 Llc | Permit type: Suppression permit | Permit status: Active | Completion date: September 26, 2017 | Permit id: 754734 | |||||
SCORE 100 Install a new 5" lateral,curb trap,fai and install 1" 13d rfss water service pa20170670605 (sfd)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" Date: March 23, 2017 Contractor: Drain Masters Plumbing Llc Client: Pbh9 Llc | Permit type: Plumbing permit | Permit status: Completed | Completion date: March 31, 2017 | Permit id: 769020 | |||||
SCORE 93 For the complete demolition of an existing attached building. Size and location as shown in application. For use to vacant lot. Date: May 25, 2016 Contractor: Ricco Construction Client: Pbh9 Llc | Permit type: Zoning/use permit | Permit status: Completed | Completion date: May 25, 2016 | Permit id: 694127 | |||||
SCORE 100 Seal lateral & curb trap & fai pa20160501049 "self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" Date: February 23, 2016 Contractor: Terry Abrams Client: Pbh9 Llc | Permit type: Plumbing permit | Permit status: Completed | Completion date: February 17, 2017 | Permit id: 671612 | |||||
For the complete demoltiion of an existing structure with the erection of an attached structure with a roof deck accessed by a roof deck access structure. Size and location as shown per application plans. Structure for use as a single family household living. Date: August 18, 2016 Client: Pbh9 Llc | Permit type: Zoning/use permit | Permit status: Completed | Completion date: August 18, 2016 | Permit id: 695406 | |||||
SCORE 93 Complete demolition of an existing attached two story, single family masonry and wood building by hand methods. All permitted demolition activity to be in accordance with approved site safety demolition plan & such plan to be maintained on site at all times in accordance with philadelphia administrative code. Complete sidewalk closure required as reflected on approved site plan and in accordance with section 3306 of the ibc. Separate street closure permit required prior to start of work. Any deviation will require an amended building permit. Work to include temporary alleyway bracing permitted until new construction on lot is completed, must be inspected in 6 month intervals Date: May 25, 2016 Contractor: Ricco Construction Client: Pbh9 Llc | Permit type: Demolition permit | Permit status: Completed | Completion date: September 2, 2016 | Permit id: 684636 |