Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Plumbing and gas ![]() Client: District Of Columbia | Applicant: James S Lynn | Permit status: Permit issued | Permit id: P1600639 | |||||
SCORE 98 Plumbing and gas ![]() ![]() Client: District Of Columbia | Permit status: Permit issued | Permit id: P1600639 | |||||
SCORE 96 Electrical ![]() ![]() Client: District Of Columbia | Permit status: Permit issued | Permit id: E1600962 | |||||
SCORE 86 Electrical ![]() ![]() Client: District Of Columbia | Permit status: Permit issued | Permit id: E1604678 | |||||
SCORE 84 1. Correct inoperative battery lowering device. Total:12,0 per 3rd party inspector 2. Correct inoperative car telephone. 3. Correct car auxiliary light. . Correct car alarm bell on auxiliary power. 5. Correct machine room air conditioner not working. 6. Remove all non-elevator equipment in machine room. 7. Provide permit for elevator repair. 8. Provide code data plate for inspection. 9. Complete life safety test. 10. Provide updated fire extinguisher for machine room. 11. Provide correction copy of elevator wiring diagram. 12. Correct car ventilating fan not working. 13. Correct fire-hat to flash when top of hoist-way and machine room sensors has been activated. ![]() ![]() Client: District Of Columbia | Permit type: Elevator - repair | Permit status: Permit issued | Permit id: Er1602471 | |||||
SCORE 56 Demolition of interior of office areas for renovation. ![]() Client: Dc Department Of General Services Dc Department Of General Servi | Permit type: Demolition | Permit status: Completed | Permit id: D1500856 | |||||
SCORE 86 Level 2 renovation to the interior spaces of the existing customer service center. Update mechanical, electrical, plumbing, technology and architectural fixtures and finishes. ![]() ![]() Client: Hares Sayed Dc Department Of General Services | Permit type: Alteration and repair | Permit status: Permit issued | Permit id: B1509446 | |||||
SCORE 96 Electrical ![]() ![]() Client: District Of Columbia | Permit status: Permit issued | Permit id: E1600962 | |||||
SCORE 98 Plumbing and gas ![]() ![]() Client: District Of Columbia | Permit status: Permit issued | Permit id: P1600639 | |||||
SCORE 82 1. Correct inoperative battery lowering device. Total:12,0 per 3rd party inspector 2. Correct inoperative car telephone. 3. Correct car auxiliary light. . Correct car alarm bell on auxiliary power. 5. Correct machine room air conditioner not working. 6. Remove all non-elevator equipment in machine room. 7. Provide permit for elevator repair. 8. Provide code data plate for inspection. 9. Complete life safety test. 10. Provide updated fire extinguisher for machine room. 11. Provide correction copy of elevator wiring diagram. 12. Correct car ventilating fan not working. 13. Correct fire-hat to flash when top of hoist-way and machine room sensors has been activated. ![]() ![]() Client: District Of Columbia | Permit type: Elevator - repair | Permit status: Permit issued | Permit id: Er1602471 | |||||
SCORE 86 Electrical ![]() ![]() Client: District Of Columbia | Permit status: Permit issued | Permit id: E1604678 | |||||
SCORE 56 The single story inspection garages will receive a level 1 alteration that includes new lighting and paint. A new single story masonry addition will be added on the north side of the building and will contain the emissions analyzer storage. ![]() Client: Hares Sayed, Sr. Project Manager Dc Department Of General Servic | Permit type: Addition alteration repair | Permit status: Permit issued | Permit id: B1511281 | |||||
SCORE 56 This supplemental permit was issued online. Use the online permit view application on dcra intranet to view the details and print a copy of the permit. Alternatively, you can copy and paste the following url into an internet browser. Https:/ospi. Dcra. Dc. Gov/ospi/printpermit. Aspx? Param=zi8iggjeilfwmi2slqbrjqedeyqsb62g ![]() Client: Dc Department Of General Services | Permit type: Mechanical | Permit status: Permit issued | Permit id: Ar94062512 |