SCORE 91 Parent parcel is map 91-12 parcel 319, is zoned r6, contains 75 sf lot area and is in a pre 1984 recorded subdivision. This permit to construct unit a of proposed horizontal property line regime duplex with 2524 sf living area and 382 sf porch areas. Sp zoning max allowed height is 22. Must comply fully with metro council bills 2014-725 and 2014-770. Contractor: Dmc Builders Permit type: Building residential - new | Permit id: T2016038228 | Parcel: 091120q00100co | |||||
SCORE 91 Parent parcel is map 91-12 parcel 319, is zoned r6, contains 75 sf lot area and is in a pre 1984 recorded subdivision. This permit to construct unit b of proposed horizontal property line regime duplex with 2524 sf living area and 382 sf porch areas. Sp zoning. Max allowed height is 22. Must comply with metro council bills 2014-725 and 2014-770. Contractor: Dmc Builders Permit type: Building residential - new | Permit id: T2016038241 | Parcel: 091120q00200co | |||||
SCORE 91 To construct a 427 sf detached garage with breezeway to rear of residence. Sp zoning. Contractor: Regent Homes Llc Permit type: Building residential - new | Permit id: T2016039639 | Parcel: 187050a03900co | |||||
SCORE 81 To construct a new single family res at 22 sqft with porches and decks... This is one of two single family houses on this property.... Split from 72-14-310... No flags.... Min 6 between houses... Side setbacks min 5... Front min 35. 7... Rear min 20... Ht max 2 stories up to 25. 5.... Need to comply with bl2014-7 which reads: the height of two detached dwelling units on a single lot cannot exceed a ratio of 1 horizontal to 1. 5 vertical for each structure. Maximum height shall be measured from the natural grade. The natural grade shall be determined based on the average elevation of most exterior corners of the front facade, to the roof line. Natural grade is the base ground elevation prior to grading.... For every feet of street frontage, or fraction thereof, one 2 inch caliper tree as listed in the urban forestry approved tree list shall be planted on the subject property. Contractor: Highland Homes Llc Permit type: Building residential - new | Permit id: T2016039916 | Parcel: 072142s00200co | |||||
SCORE 81 To construct a new single family res at 22 sqft with porches and decks... This is one of two single family houses on this property.... Split from 72-14-310... No flags.... Min 6 between houses... Side setbacks min 5... Front min 35. 7... Rear min 20... Ht max 2 stories up to 25. 5.... Need to comply with bl2014-7 which reads: the height of two detached dwelling units on a single lot cannot exceed a ratio of 1 horizontal to 1. 5 vertical for each structure. Maximum height shall be measured from the natural grade. The natural grade shall be determined based on the average elevation of most exterior corners of the front facade, to the roof line. Natural grade is the base ground elevation prior to grading.... For every feet of street frontage, or fraction thereof, one 2 inch caliper tree as listed in the urban forestry approved tree list shall be planted on the subject property. Pursuant ordinance # 2006-1263 metropolitan code of laws, i (the holder on this permit) hereby certify that all construction Contractor: Highland Homes Llc Permit type: Building residential - new | Permit id: T2016039909 | Parcel: 072142s00100co | |||||
SCORE 91 This permit is to construct unit a of homes at 34 benham ave, a proposed horizontal property line regime duplex with 3860sf of living area, 728sf carport and 312sf porch area. Units detached. Maximum allowed height is feet. 63. 4 minimum front setback; 5 minimum side setback; 20minimum rear setback. Parent parcel is map 72-16 parcel 293, is zoned r20, contains 20,000sf lot area and is located in a pre-1984 parcel. Must comply with metro council bills 2014-725 and 2014-770. Pursuant to ordinance no. 2006-1263 of the metropolitan code of laws, i (the holder on this permit) hereby certify that all construction and demolition waste generated by any and all activities governed by this permit shall be disposed of in an approved landfill. Further, i certify that no construction and demolition waste shall be stored on the property in violation of any provision of the metropolitan code Contractor: Watson Daryl Permit type: Building residential - new | Permit id: T2016040546 | Parcel: 117074d00100co | |||||
SCORE 91 His permit is to construct unit b of homes at 34 benham ave, a proposed horizontal property line regime duplex with 3867sf of living area, 680sf carport and 184sf porch area. Units detached. Maximum allowed height is 39. 5 feet. 63. 4 minimum front setback; 5 minimum side setback; 20minimum rear setback. Parent parcel is map 72-16 parcel 293, is zoned r20, contains 20,000sf lot area and is located in a pre-1984 parcel. Must comply with metro council bills 2014-725 and 2014-770. Pursuant to ordinance no. 2006-1263 of the metropolitan code of laws, i (the holder on this permit) hereby certify that all construction and demolition waste generated by any and all activities governed by this permit shall be disposed of in an approved landfill. Further, i certify that no construction and demolition waste shall be stored on the property in violation of any provision of the metropolitan code Contractor: Watson Daryl Permit type: Building residential - new | Permit id: T2016040562 | Parcel: 117074d00200co | |||||
SCORE 84 To construct a new single family res at 20 sqft with porches and decks... This is one of two single family houses on this one property... Split from 91-13-99...... Min 6 between houses... Side setbacks min 5.... Rear mn 20...... Houses 16 wide... Max ht... 2 stories and 24... As measured per bl2014-7 which reads: the height of two detached dwelling units on a single lot cannot exceed a ratio of 1 horizontal to 1. 5 vertical for each structure. Maximum height shall be measured from the natural grade. The natural grade shall be determined based on the average elevation of most exterior corners of the front facade, to the roof line. Natural grade is the base ground elevation prior to grading.... For every feet of street frontage, or fraction thereof, one 2 inch caliper tree as listed in the urban forestry approved tree list shall be planted on the subject property..... Pursuant ordinance # 2006-1263 metropolitan code of laws, i (the holder on this permit) hereby certify that all construction & demol Value: $225,300 Contractor: Music City Electrical Engineering Llc Permit type: Building residential - new | Permit id: T2016040924 | Parcel: 091130p00200co | |||||
SCORE 84 To construct a new single family res at 20 sqft with porches and decks... This is one of two single family houses on this one property... Split from 91-13-101...... Min 6 between houses... Side setbacks min 5.... Rear mn 20...... Houses 16 wide... Max ht... 2 stories and 24... As measured per bl2014-7 which reads: the height of two detached dwelling units on a single lot cannot exceed a ratio of 1 horizontal to 1. 5 vertical for each structure. Maximum height shall be measured from the natural grade. The natural grade shall be determined based on the average elevation of most exterior corners of the front facade, to the roof line. Natural grade is the base ground elevation prior to grading.... For every feet of street frontage, or fraction thereof, one 2 inch caliper tree as listed in the urban forestry approved tree list shall be planted on the subject property..... Pursuant ordinance # 2006-1263 metropolitan code of laws, i (the holder on this permit) hereby certify that all construction & demo Contractor: Music City Electrical Engineering Llc Permit type: Building residential - new | Permit id: T2016040907 | Parcel: 091130o00200co | |||||
SCORE 84 To construct a new single family res at 20 sqft with porches and decks... This is one of two single family houses on this one property... Split from 91-13-99...... Min 6 between houses... Side setbacks min 5.... Rear mn 20...... Houses 16 wide... Max ht... 2 stories and 24... As measured per bl2014-7 which reads: the height of two detached dwelling units on a single lot cannot exceed a ratio of 1 horizontal to 1. 5 vertical for each structure. Maximum height shall be measured from the natural grade. The natural grade shall be determined based on the average elevation of most exterior corners of the front facade, to the roof line. Natural grade is the base ground elevation prior to grading.... For every feet of street frontage, or fraction thereof, one 2 inch caliper tree as listed in the urban forestry approved tree list shall be planted on the subject property..... Pursuant ordinance # 2006-1263 metropolitan code of laws, i (the holder on this permit) hereby certify that all construction & demol Value: $225,300 Contractor: Music City Electrical Engineering Llc Permit type: Building residential - new | Permit id: T2016040919 | Parcel: 091130p00100co | |||||
SCORE 84 To construct a new single family res at 20 sqft with porches and decks... This is one of two single family houses on this one property... Split from 91-13-100...... Min 6 between houses... Side setbacks min 5.... Rear mn 20...... Houses 16 wide... Max ht... 2 stories and 24... As measured per bl2014-7 which reads: the height of two detached dwelling units on a single lot cannot exceed a ratio of 1 horizontal to 1. 5 vertical for each structure. Maximum height shall be measured from the natural grade. The natural grade shall be determined based on the average elevation of most exterior corners of the front facade, to the roof line. Natural grade is the base ground elevation prior to grading.... For every feet of street frontage, or fraction thereof, one 2 inch caliper tree as listed in the urban forestry approved tree list shall be planted on the subject property..... Pursuant ordinance # 2006-1263 metropolitan code of laws, i (the holder on this permit) hereby certify that all construction & demo Value: $225,300 Contractor: Music City Electrical Engineering Llc Permit type: Building residential - new | Permit id: T2016040915 | Parcel: 091130q00200co | |||||
SCORE 84 To construct a new single family res at 20 sqft with porches and decks... This is one of two single family houses on this one property... Split from 91-13-100...... Min 6 between houses... Side setbacks min 5.... Rear mn 20...... Houses 16 wide... Max ht... 2 stories and 24... As measured per bl2014-7 which reads: the height of two detached dwelling units on a single lot cannot exceed a ratio of 1 horizontal to 1. 5 vertical for each structure. Maximum height shall be measured from the natural grade. The natural grade shall be determined based on the average elevation of most exterior corners of the front facade, to the roof line. Natural grade is the base ground elevation prior to grading.... For every feet of street frontage, or fraction thereof, one 2 inch caliper tree as listed in the urban forestry approved tree list shall be planted on the subject property..... Pursuant ordinance # 2006-1263 metropolitan code of laws, i (the holder on this permit) hereby certify that all construction & demo Value: $225,300 Contractor: Music City Electrical Engineering Llc Permit type: Building residential - new | Permit id: T2016040910 | Parcel: 091130q00100co | |||||
SCORE 84 To construct a new single family res at 20 sqft with porches and decks... This is one of two single family houses on this one property... Split from 91-13-101...... Min 6 between houses... Side setbacks min 5.... Rear mn 20...... Houses 16 wide... Max ht... 2 stories and 24... As measured per bl2014-7 which reads: the height of two detached dwelling units on a single lot cannot exceed a ratio of 1 horizontal to 1. 5 vertical for each structure. Maximum height shall be measured from the natural grade. The natural grade shall be determined based on the average elevation of most exterior corners of the front facade, to the roof line. Natural grade is the base ground elevation prior to grading.... For every feet of street frontage, or fraction thereof, one 2 inch caliper tree as listed in the urban forestry approved tree list shall be planted on the subject property..... Pursuant ordinance # 2006-1263 metropolitan code of laws, i (the holder on this permit) hereby certify that all construction & demo Contractor: Music City Electrical Engineering Llc Permit type: Building residential - new | Permit id: T2016040892 | Parcel: 091130o00100co | |||||
SCORE 84 To demolish existing single family residence. Not to be buried or burned on site. Pursuant to ordinance no 2008-1263 of the metropolitan code of laws, i , holder of this permit, hereby certify that all construction and demolition waste generated by any and all activities governed by this permit shall be disposed of in an approved landfill. Further, i certify that no construction or demolition waste shall be stored on the property in violation of any provisions of the metropolitan code. For every feet of street frontage, or fraction thereof, one 2 inch caliper tree as listed in the urban forestry approved tree list shall be planted on the subject property. Permit type: Building demolition permit | Permit id: 2017015553 | Parcel: 118060y00200co | |||||
SCORE 81 This permit is to construct unit b of proposed horizontal property line regime homes at 616 ries avenue duplex with 19 sqft of living area and 1 sqft of porch areas. Units detached. Maximum allowed height is 27. 5 natural grade to peak. 32 minimum front setback; 5 minimum side setback; minimum rear setback not to build over or obstruct any easements on property must comply with metro council bills 2014-725 and 2014-770. For every feet of street frontage, or fraction thereof, one 2 inch caliper tree as listed in the urban forestry approved tree list shall be planted on the subject property. Pursuant to ordinance no. 2006-1263 of the metropolitan code of laws, i (the holder on this permit) hereby certify that all construction and demolition waste generated by any and all activities governed by this permit shall be disposed of in an approved landfill. Further, i certify that no construction and demolition waste shall be stored on the property in violation of any provision of the met Contractor: Brian Chester Construction Llc Permit type: Building residential - addition | Permit id: T2016070878 | Parcel: 091050t00200co | |||||
SCORE 78 This permit is to construct unit b of proposed horizontal property line regime duplex with 1,714 sqft of living area and 68 sqft of porch areas. Units detached. Maximum allowed height is 35 feet... ... 46 minimum front setback; 5 minimum side setback; minimum rear setback not to build over or obstruct any easements on propertyparent parcel is map 90-12 parcel 280, is zoned r8, contains 14,2 sf lot area and is lot 2 of pergerson subdivision and is of record in the office of the county register prior to august 1, 1984 must comply with metro council bills 2014-725 and 2014-770. For every feet of street frontage, or fraction thereof, one 2 inch caliper tree as listed in the urban forestry approved tree list shall be planted on the subject property. Pursuant to ordinance no. 2006-1263 of the metropolitan code of laws, i (the holder on this permit) hereby certify that all construction and demolition waste generated by any and all activities governed by this permit shall be disposed of Contractor: Skyview Property Group Llc Permit type: Building residential - addition | Permit id: T2017000501 | Parcel: 090120r00200co | |||||
SCORE 95 To build a 2205 sq. Ft. Single family house with an attached 427 sq. Ft. Two car garage. Plans to be submitted to planning for udo approval. Value: $321,576 Contractor: Beazer Homes Corp Permit type: Building residential - new | Permit id: T2016061859 | Parcel: 097020a56500co |