Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 89 13308 Julian Ave Lakeside Ca 92040 40 sf reroof if a re-roof project is proposed, the following specifications apply. Existing roofing material comp shingles proposed roofing material comp shingles manufacturer owens corning brand and model duration preminum - cool shingles harbor fog color (if cool roof required) --- built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) -- required building inspector field verification (if applicable) --- note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Date: November 26, 2014 Contractor: J D F Construction Inc Permit type: Residential alteration-addn | Permit status: Completed | Completion date: January 6, 2015 | Permit id: Pds2014-Resalt- | |||||
SCORE 89 528 Carlsbad St Spring Valley Ca 91977 - 28 sqft re-roof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model duration color (if cool roof required) terracotta built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Issued | Permit id: Pds2015-Resalt- | |||||
SCORE 89 847 Sacramento Ave Spring Valley Ca 91977 - 24 sqft re-roof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owen corning brand and model duration color (if cool roof required) antique silver built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: July 23, 2015 | Permit id: Pds2015-Resalt- | |||||
SCORE 89 13308 Julian Ave, Lakeside, Ca 92040 40 sf reroof if a re-roof project is proposed, the following specifications apply. Existing roofing material: comp shingles proposed roofing material: comp shingles manufacturer: owens corning brand and model: duration preminum - cool shingles harbor fog color (if cool roof required): --- built-up roofing assembly system number per attached listing report (if applicable): specific exemption from cool roof requirements (if applicable): -- required building inspector field verification (if applicable): --- note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Date: November 26, 2014 Contractor: J D F Construction Inc Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2014-Resalt- | Parcel: 395-060-55-00 | |||||
SCORE 89 9653 Birch St, Spring Valley, Ca 91977 Replace furnace, coil, duct, ac and thermostat for existing sfd. Date: October 1, 2015 Contractor: J D F Construction Inc Permit type: Residential alterati | Permit status: Issued | Permit id: Pds2015-Resalt- | Parcel: 579-388-23-00 | |||||
SCORE 89 12157 Wintergreen Dr, Lakeside, Ca 92040 Misc mech permit for existing furnace change out in sfd, no new elec, plumb or duct work. Date: February 11, 2016 Contractor: J D F Construction Inc Permit type: Mechanical only | Permit status: Completed | Permit id: Pds2016-Resalt- | Parcel: 3945521601 | |||||
SCORE 89 Date: November 17, 2015 Contractor: J D F Construction Inc Permit type: Mechanical only | Permit status: Completed | Permit id: Pds2015-Resalt- | Parcel: 5113121400 | |||||
SCORE 89 9113 Gotta Pl, Lakeside, Ca 92040 24 sf re-roof for (e) sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingle proposed roofing material asphalt shingle manufacturer owens corning brand and model duration color (if cool roof required) n a built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) adding insulation to r38 required building inspector field verification (if applicable) adding insulation to r38 note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | |||||
SCORE 89 Date: July 20, 2016 Contractor: J D F Construction Inc Permit type: Mechanical only | Permit status: Issued | Permit id: Pds2016-Resalt- | Parcel: 2881821900 | |||||
SCORE 89 9147 Bubbling Wells Rd, Lakeside, Ca 92040 Res reroof - 3000sf () if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model shasta white-oakridge color (if cool roof required) white built-up roofing assembly system number per attached listing report (if applicable) na specific exemption from cool roof requirements (if applicable) na required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Issued | Permit id: Pds2016-Resalt- | Parcel: 3972320500 | |||||
SCORE 89 7 Felicita Ave, Spring Valley, Ca 91977 18 sf re-roof () if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model trudefinition duration color (if cool roof required) amber built-up roofing assembly system number per attached listing report (if applicable) n/a specific exemption from cool roof requirements (if applicable) n/a required building inspector field verification (if applicable) old roofing to be removed note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | Parcel: 5843804600 | |||||
SCORE 89 3855 Monserate Ter, Fallbrook, Ca 92028 4300sf re-roof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material clay proposed roofing material ashphalt manufacturer owens corning brand and model tru def duration color (if cool roof required) black onyx built-up roofing assembly system number per attached listing report (if applicable) na specific exemption from cool roof requirements (if applicable) install r38 insulation required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2017-Resalt- | Parcel: 1234805400 | |||||
SCORE 89 1924 W El Norte Pkwy, Escondido, Ca 92026 25 sqft re-roof if a re-roof project is proposed, the following specifications apply. Existing roofing material compo shingles proposed roofing material compo shingles manufacturer owens corning brand and model true definition duration amber color (if cool roof required) orange built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2017-Resalt- | Parcel: 2263101100 | |||||
SCORE 89 226 Lento Ln, El Cajon, Ca 92021 Re-roof for (e) sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt / comp shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model trudefinition, duration color (if cool roof required) oakridge, amber. Crrc product id# 0890-/0009 built-up roofing assembly system number per attached listing report (if applicable) no specific exemption from cool roof requirements (if applicable) no required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | Parcel: 5092310800 | |||||
SCORE 89 11459 Eucalyptus Hills Dr, Lakeside, Ca 92040 35 sf re-roof () if a re-roof project is proposed, the following specifications apply. Existing roofing material shingles proposed roofing material shingles manufacturer owens corning brand and model tru definition duration color (if cool roof required) shasta white built-up roofing assembly system number per attached listing report (if applicable) n/a specific exemption from cool roof requirements (if applicable) n/a required building inspector field verification (if applicable) n/a note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | Parcel: 3771312000 | |||||
SCORE 89 528 Carlsbad St, Spring Valley, Ca 91977 Hra- 28 sqft re-roof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material: asphalt shingles proposed roofing material: asphalt shingles manufacturer: owens corning brand and model: duration color (if cool roof required): terracotta built-up roofing assembly system number per attached listing report (if applicable): specific exemption from cool roof requirements (if applicable): required building inspector field verification (if applicable): note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Issued expired | Permit id: Pds2015-Resalt- | Parcel: 583-602-17-00 | |||||
SCORE 89 847 Sacramento Ave, Spring Valley, Ca 91977 Hra- 24 sqft re-roof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material: asphalt shingles proposed roofing material: asphalt shingles manufacturer: owen corning brand and model: duration color (if cool roof required): antique silver built-up roofing assembly system number per attached listing report (if applicable): specific exemption from cool roof requirements (if applicable): required building inspector field verification (if applicable): note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2015-Resalt- | Parcel: 584-320-21-00 | |||||
SCORE 89 Date: July 18, 2016 Contractor: J D F Construction Inc Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 16041-70000-251 | |||||
SCORE 89 Date: December 28, 2015 Contractor: J D F Construction Inc Permit status: Issued | Current use: 1 or 2 family dwelling | Permit id: 15044-40000-137 | |||||
SCORE 89 Date: May 18, 2016 Contractor: J D F Construction Inc Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 16041-40000-174 | |||||
SCORE 89 Date: November 27, 2017 Contractor: J D F Construction Inc Permit status: Issued | Current use: 1 or 2 family dwelling | Permit id: 17044-40000-147 | |||||
SCORE 89 Date: December 18, 2017 Contractor: J D F Construction Inc Permit status: Issued | Current use: 1 or 2 family dwelling | Permit id: 17044-70000-157 | |||||
SCORE 89 Date: December 28, 2017 Contractor: J D F Construction Inc Permit status: Issued | Current use: 1 or 2 family dwelling | Permit id: 17044-70000-161 | |||||
SCORE 89 Date: August 8, 2017 Contractor: J D F Construction Inc Permit status: Issued | Current use: 1 or 2 family dwelling | Permit id: 17044-70000-099 | |||||
SCORE 89 Date: May 18, 2016 Contractor: J D F Construction Inc Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 16041-40000-174 | |||||
SCORE 89 Date: August 1, 2017 Contractor: J D F Construction Inc Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 17044-40000-089 | |||||
SCORE 89 Date: August 30, 2017 Contractor: J D F Construction Inc Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 17044-70000-110 | |||||
SCORE 89 Date: August 29, 2017 Contractor: J D F Construction Inc Permit status: Issued | Current use: 1 or 2 family dwelling | Permit id: 17044-70000-110 | |||||
SCORE 89 Date: October 3, 2017 Contractor: J D F Construction Inc Permit status: Issued | Current use: 1 or 2 family dwelling | Permit id: 17044-70000-125 | |||||
SCORE 89 Date: June 21, 2017 Contractor: J D F Construction Inc Permit status: Issued | Current use: 1 or 2 family dwelling | Permit id: 17041-10000-210 | |||||
SCORE 89 Date: April 19, 2017 Contractor: J D F Construction Inc Permit status: Issued | Current use: Apartment | Permit id: 17044-70000-043 | |||||
SCORE 89 Date: December 28, 2015 Contractor: J D F Construction Inc Permit status: Issued | Current use: 1 or 2 family dwelling | Permit id: 15044-40000-137 | |||||
SCORE 89 Date: July 14, 2017 Contractor: J D F Construction Inc Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 17044-70000-080 | |||||
SCORE 89 Date: July 18, 2016 Contractor: J D F Construction Inc Permit status: Permit finaled | Current use: 1 or 2 family dwelling | Permit id: 16041-70000-251 | |||||
SCORE 89 Date: July 20, 2016 Contractor: J D F Construction Inc Permit type: Residential alteration-addn | Permit status: Issued | Permit id: Pds2016-Resalt- | |||||
SCORE 89 12157 Wintergreen Dr Lakeside Ca 92040 Misc mech permit for existing furnace change out in sfd, no new elec, plumb or duct work. Date: February 11, 2016 Contractor: J D F Construction Inc Permit type: Residential alteration-addn | Permit status: Completed | Completion date: April 13, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 89 Date: November 17, 2015 Contractor: J D F Construction Inc Permit type: Residential alteration-addn | Permit status: Completed | Completion date: May 5, 2016 | Permit id: Pds2015-Resalt- | |||||
SCORE 89 9653 Birch St Spring Valley Ca 91977 Replace furnace, coil, duct, ac and thermostat for existing sfd. Date: October 1, 2015 Contractor: J D F Construction Inc Permit type: Residential alteration-addn | Permit status: Issued | Permit id: Pds2015-Resalt- | |||||
SCORE 89 9147 Bubbling Wells Rd Lakeside Ca 92040 Res reroof - 3000sf () if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model shasta white-oakridge color (if cool roof required) white built-up roofing assembly system number per attached listing report (if applicable) na specific exemption from cool roof requirements (if applicable) na required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Issued | Permit id: Pds2016-Resalt- | |||||
SCORE 89 9113 Gotta Pl Lakeside Ca 92040 24 sf re-roof for (e) sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingle proposed roofing material asphalt shingle manufacturer owens corning brand and model duration color (if cool roof required) n/a built-up roofing assembly system number per attached listing report (if applicable) n/a specific exemption from cool roof requirements (if applicable) adding insulation to r38 required building inspector field verification (if applicable) adding insulation to r38 note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: August 12, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 89 226 Lento Ln El Cajon Ca 92021 Re-roof for (e) sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt / comp shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model trudefinition, duration color (if cool roof required) oakridge, amber. Crrc product id# 0890-/0009 built-up roofing assembly system number per attached listing report (if applicable) no specific exemption from cool roof requirements (if applicable) no required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: June 29, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 89 7 Felicita Ave Spring Valley Ca 91977 18 sf re-roof () if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model trudefinition duration color (if cool roof required) amber built-up roofing assembly system number per attached listing report (if applicable) n/a specific exemption from cool roof requirements (if applicable) n/a required building inspector field verification (if applicable) old roofing to be removed note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: April 25, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 89 11459 Eucalyptus Hills Dr Lakeside Ca 92040 35 sf re-roof () if a re-roof project is proposed, the following specifications apply. Existing roofing material shingles proposed roofing material shingles manufacturer owens corning brand and model tru definition duration color (if cool roof required) shasta white built-up roofing assembly system number per attached listing report (if applicable) n/a specific exemption from cool roof requirements (if applicable) n/a required building inspector field verification (if applicable) n/a note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: March 7, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 89 1924 W El Norte Pkwy Escondido Ca 92026 25 sqft re-roof if a re-roof project is proposed, the following specifications apply. Existing roofing material compo shingles proposed roofing material compo shingles manufacturer owens corning brand and model true definition duration amber color (if cool roof required) orange built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Addn | Permit status: Completed | Completion date: March 27, 2017 | Permit id: Pds2017-Resalt- | |||||
SCORE 89 3855 Monserate Ter Fallbrook Ca 92028 4300sf re-roof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material clay proposed roofing material ashphalt manufacturer owens corning brand and model tru def duration color (if cool roof required) black onyx built-up roofing assembly system number per attached listing report (if applicable) na specific exemption from cool roof requirements (if applicable) install r38 insulation required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Addn | Permit status: Completed | Completion date: May 10, 2017 | Permit id: Pds2017-Resalt- | |||||
SCORE 89 1407 Grand Ave Spring Valley Ca 91977 29 sf re-roof like for like (comp shingle) for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material comp proposed roofing material comp manufacturer owens corning brand and model tru. Def. Color (if cool roof required) amber built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Date: February 11, 2016 Contractor: J D F Construction Inc Permit type: Residential alteration-addn | Permit status: Completed | Completion date: March 30, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 89 1407 Grand Ave, Spring Valley, Ca 91977 29 sf re-roof like for like (comp shingle) for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material comp proposed roofing material comp manufacturer owens corning brand and model tru. Def. Color (if cool roof required) amber built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Date: February 11, 2016 Contractor: J D F Construction Inc Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | |||||
SCORE 89 2701 Willowhaven Dr Los Angeles Ca T/o exist roof on house only, 2 s. F. Of resheat and install lifetime labor warranty composition shingles Applicant: Perez Ronnie | Permit status: Finaled | Completion date: December 28, 2015 | Expiration date: November 19, 2016 | Permit id: 1511200013 | |||||
SCORE 89 Applicant: Evans Mark | Permit status: Finaled | Completion date: October 23, 2015 | Expiration date: September 24, 2016 | Permit id: 1509250040 | |||||
SCORE 89 5229 Avenue L 8 Quartz Hill Ca T/off and reroof cool roof asphalt shingles, 28 sqs replace 2 sq ft of plywood decking Applicant: Radliffe J | Permit status: Finaled | Completion date: February 23, 2016 | Expiration date: December 28, 2016 | Permit id: 1512290035 | |||||
SCORE 89 Permit type: 0 | Permit id: 16-10-092 | Parcel: 067090044000 | |||||
SCORE 89 Permit type: 0 | Permit id: 16-10-091 | Parcel: 014297008000 | |||||
SCORE 89 Date: October 12, 2016 Contractor: J D F Construction Inc Permit id: 16-10-091 | Parcel: 014297008000 | |||||
SCORE 89 Date: October 12, 2016 Contractor: J D F Construction Inc Permit id: 16-10-092 | Parcel: 067090044000 | |||||
SCORE 89 2574 Doville Ranch Rd Fallbrook Ca 92028 Installing hvac for (e) sfd 11 15 17 plan change. See coa tnh misc mechancial and electrical to relocate hvac unit to roof with ducting Date: November 13, 2017 Contractor: J D F Construction Inc Permit type: Addn | Permit status: Issued | Permit id: Pds2017-Resalt- | |||||
SCORE 89 Date: December 8, 2017 Contractor: J D F Construction Inc Permit type: Addn | Permit status: Issued | Permit id: Pds2017-Resalt- | |||||
SCORE 89 8147 Dorchester St Spring Valley Ca 91977 Re-roof if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model true definition duration color (if cool roof required) amber crrc product id#0890-0009 built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) no required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Addn | Permit status: Completed | Completion date: July 26, 2017 | Permit id: Pds2017-Resalt- | |||||
SCORE 89 24225 Rutherford Rd Ramona Ca 92065 36 sqft (re-sheets use same tile) if a re-roof project is proposed, the following specifications apply. Existing roofing material tile (clay) proposed roofing material same tile manufacturer monier brand and model (will replace underlayment with radiant barrier and (30# felt) color (if cool roof required) n a built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) install new radiant barrier required building inspector field verification (if applicable) yes, install new radiant barrier note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Addn | Permit status: Completed | Completion date: May 26, 2017 | Permit id: Pds2017-Resalt- | |||||
SCORE 89 8147 Dorchester St, Spring Valley, Ca 91977 Re-roof if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model true definition duration color (if cool roof required) amber crrc product id#0890-0009 built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) no required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2017-Resalt- | Parcel: 5774630700 | |||||
SCORE 89 24225 Rutherford Rd, Ramona, Ca 92065 36 sqft (re-sheets use same tile) if a re-roof project is proposed, the following specifications apply. Existing roofing material tile (clay) proposed roofing material same tile manufacturer monier brand and model (will replace underlayment with radiant barrier and (30# felt) color (if cool roof required) n a built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) install new radiant barrier required building inspector field verification (if applicable) yes, install new radiant barrier note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2017-Resalt- | Parcel: 2885513300 |