SCORE 75 4105 Brandywine St Nw, Washington, Dc 20016 Conduct 3 soil borings, b-1 through b-3, 8 inches in diameter, up to feet deep, using hollow stem auger drilling methods at the locations shown on the attached boring location plan. ![]() ![]() Client: Friendship Animal Hospital | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300211 | |||||
SCORE 75 5 Indiana Ave Nw, Washington, Dc 20001 Conduct four soil borings, b-1 through b-4, 8 inches in diameter, up to 75 feet deep, using hollow stem auger methods at the locations shown on the attached boring location plan. Borings b-1 and b-4 will be converted into 1 inch ground water monitoring wells. ![]() ![]() Client: District Of Columbia Courts | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300109 | |||||
SCORE 75 16 Columbia Rd Nw, Washington, Dc 20009 Conduct 7 soil borings b-1 through b-7, 8 inches in diameter, up to feet deep, using hollow stem auger drilling methods at the locations shown on the attached boring location plan. ![]() ![]() Client: Hsa-Uwc | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300187 | |||||
SCORE 75 1525 H St Nw, Washington, Dc 20005 The work includes exploratory soil test borings for soil sampling to assess foundation design consideration. These holes will not be converted for temporary or permanent water collection or monitoring. A total of 4 holes numbered tb-1 through 4 at locations on the parish property. Maximum depth 25 feet between 6 to 8 inches in diameter dry hollow and solid stem augering drill methods will be used with grouting upon completion and excess cuttings disposed. Reference - subsurface exploration work plan, rev. 1 dated 1. 29. 15 ![]() ![]() Client: The Vestry Of St. Johns Church Lafayette Square | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1500148 | |||||
SCORE 75 4105 Brandywine St Nw, Washington, Dc 20016 Conduct 3 soil borings, b-1 through b-3, 8 inches in diameter, up to feet deep, using hollow stem auger drilling methods at the locations shown on the attached boring location plan. ![]() ![]() Client: Friendship Animal Hospital | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300211 | |||||
SCORE 75 5 Indiana Ave Nw, Washington, Dc 20001 Conduct four soil borings, b-1 through b-4, 8 inches in diameter, up to 75 feet deep, using hollow stem auger methods at the locations shown on the attached boring location plan. Borings b-1 and b-4 will be converted into 1 inch ground water monitoring wells. ![]() ![]() Client: District Of Columbia Courts | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300109 | |||||
SCORE 75 16 Columbia Rd Nw, Washington, Dc 20009 Conduct 7 soil borings b-1 through b-7, 8 inches in diameter, up to feet deep, using hollow stem auger drilling methods at the locations shown on the attached boring location plan. ![]() ![]() Client: Hsa-Uwc | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1300187 | |||||
SCORE 75 1525 H St Nw, Washington, Dc 20005 The work includes exploratory soil test borings for soil sampling to assess foundation design consideration. These holes will not be converted for temporary or permanent water collection or monitoring. A total of 4 holes numbered tb-1 through 4 at locations on the parish property. Maximum depth 25 feet between 6 to 8 inches in diameter dry hollow and solid stem augering drill methods will be used with grouting upon completion and excess cuttings disposed. Reference - subsurface exploration work plan, rev. 1 dated 1. 29. 15 ![]() ![]() Client: The Vestry Of St. Johns Church Lafayette Square | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1500148 |