Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 67 3401 4th Street Se Washington Dc The proposed work will include 4 soil borings to depths between ft and 80ft deep the soil boring diameter will be 4 inches drilled by a hollow stem auger. Upon completion, borings will be grouted using a bentonite slurry -two pounds bentonite power to one gallon water- tremie grouted from the bottom up, and abandoned, as pr site plans, work plan report, dc well construction application and d well schematic form, for the dc ballou high school. This construction permit requires a separate occupancy permit. The attached plans and conditions are apart of this permit. If steel plates are used at this job site an additional permit is needed. Date: October 10, 2012 Client: D.C Public Ballou High School. D.C Public Ballou High School. | Permit type: Excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: February 26, 2013 | Permit id: Pa75985 | |||||
SCORE 67 4225 Connecticut Avenue Nw Washington Dc Install three monitoring wells on public space. The monitoring well diameter is six inches and the depth is between 35 ft. To ft, as per site plans, work plans report, dc well construction application and dc well schematic form for the 4225 connecticut ave nw ltd. Partnership. Date: October 16, 2012 Permit type: Excavation; monitoring well (single), excavation; monitoring well (each addl) | Permit status: Permit expired | Expiration date: May 16, 2013 | Permit id: Pa76173 | |||||
SCORE 67 1785 Massachusetts Avenue Nw Washington Dc As part of the geotechnical investigation, we propose to drill two soil borings. The soil borings diameter is four inches between to feet deep. Upon completion borings will be grouted using bentonite slurry -two pounds bentonite powder to one gallon water- tremie grouted from the bottom up, and abandoned, as er site plans, work plans report, dc well construction and schematic forms, for the american enterprise institute poc, mason osmund. This construction permit requires a separate occupancy permit. The attached plans and conditions are a part of this permit. If steel plates are used at this job site an additional permit is needed. Date: January 25, 2013 Client: American Enterprise Institute Poc M.O. American Enterprise Institute Poc M.O. | Permit type: Excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: May 30, 2013 | Permit id: Pa78885 | |||||
SCORE 67 17 Euclid Street Nw Washington Dc As part of the geotechnical investigation, to propose to drill two soil boring. The borings diameter will be four inches by seventy-five feet of depth. Upon completion, the borings will be grouted using a bentonite slurry -two pound bentonite powder to one gallon water- tremie grouted for the bottom up, and abandoned. Sampling if performed through the center opening in the hollow stem auger, by standard methods, after removal of the plug, as per site plan, work plan report, dc well construction and schematic application for the adams hotel owner, llc poc- jack lamstein. Date: March 12, 2013 Client: Adams Morgan Hotel Owner, Llc Poc, J.L. Adams Morgan Hotel Owner, Llc Poc, J.L | Permit type: Excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: June 20, 2013 | Permit id: Pa80365 |